• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7240-7DC36-0KA0 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7240-7DC36-0KA0 SIMATIC IPC277D

    € 2.151,00

    Reset
    Clear
    SKU: 6AV7240-7DC36-0KA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7240-7DC36-0KA0 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding human-machine interface applications. This unit is a 15-inch widescreen industrial panel PC that integrates computing power and display functionality into a single front-panel-mount device. It is engineered for continuous operation in industrial environments and is fully compatible with the SIMATIC software ecosystem.

    The IPC277D features a 15.6-inch widescreen TFT display with a resistive or projected capacitive touch interface, depending on the variant, and delivers a resolution of 1366 x 768 pixels. It is powered by an Intel Atom or Celeron processor and supports Windows Embedded Standard 7 or Windows 7 operating systems, providing a familiar environment for SCADA and HMI software deployment. Communication interfaces include PROFINET, USB, and serial ports, enabling integration with a wide range of Siemens and third-party automation components. The unit is built to IP65 protection on the front panel, making it resistant to dust and water ingress in harsh production environments.

    The SIMATIC IPC277D is widely used in manufacturing, process automation, and machine tool industries where a robust, panel-integrated PC-based HMI is required. Its compatibility with WinCC, WinCC flexible, and other SIMATIC software packages makes it a practical choice for visualization and control tasks on production lines, packaging machinery, and process control stations. The fanless or low-noise design options make it suitable for cleanroom and noise-sensitive environments.

    Technical Specifications

    Display Size 15.6 inch widescreen
    Display Resolution 1366 x 768 pixels
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Power Consumption Approx. 60 W
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interfaces 2x PROFINET (RJ45), 4x USB 2.0, 1x RS-232/RS-422/RS-485
    Mounting Panel mounting (front flush)
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC IPC277D

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence.
    Check storage medium integrity, verify OS installation, and inspect RAM modules for faults. Re-image the storage device if necessary.
    Event ID: 200
    Overtemperature condition detected in the panel PC enclosure.
    Check ambient temperature and ensure ventilation clearances are maintained. Clean air vents and verify that the cooling system or heat spreader is functioning correctly.
    Event ID: 300
    PROFINET communication link failure or loss of network connection.
    Inspect RJ45 cable connections, verify network switch configuration, and check PROFINET device settings in the connected PLC or controller.
    Event ID: 400
    Touchscreen input not responding or calibration error detected.
    Recalibrate the touchscreen via the Windows control panel or SIMATIC settings. If unresponsive, check the touch controller connection internally or replace the touch overlay.
    Event ID: 500
    Storage device read/write error or compact flash/SSD failure.
    Back up data immediately if possible. Replace the storage medium with a compatible Siemens-approved device and restore the OS image.
    Event ID: 600
    24 V DC supply voltage out of tolerance or power interruption detected.
    Measure the supply voltage at the power connector. Ensure the supply is within the 24 V DC nominal range and check for loose connections or undersized power supply units.
    Event ID: 700
    USB device error or unrecognized USB peripheral connected.
    Disconnect and reconnect the USB device. Verify driver compatibility with the installed OS version. Avoid using non-industrial USB hubs.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7240-7DC36-0KA0?

    The SIMATIC IPC277D operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs in this series.

    What operating system does the IPC277D support?

    The IPC277D supports Windows Embedded Standard 7 (WES7) and Windows 7 Professional, depending on the ordered configuration. Some variants also support Windows 10 IoT Enterprise.

    Is the 6AV7240-7DC36-0KA0 compatible with Siemens WinCC?

    Yes, the SIMATIC IPC277D is fully compatible with Siemens WinCC, WinCC flexible, and other SIMATIC HMI software packages.

    What is the front panel protection rating of this panel PC?

    The front panel of the IPC277D carries an IP65 protection rating, making it suitable for environments where dust and water spray may be present.

    What communication interfaces are available on this unit?

    The unit provides two PROFINET ports (RJ45), four USB 2.0 ports, and one configurable serial port (RS-232/RS-422/RS-485), supporting integration with a wide range of automation devices.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the supply is within tolerance and that the power LED indicator is active.

    If voltage is correct but display remains blank, attempt a hard reset by holding the power button. If the issue persists, inspect the internal display cable connections or replace the backlight inverter or display assembly.

    Touchscreen does not respond to input

    Determine whether the issue is hardware or software by connecting an external USB mouse to verify OS responsiveness. Check Device Manager for touch controller errors.

    Recalibrate the touchscreen through the Windows control panel. If calibration fails, update or reinstall the touch controller driver. For persistent hardware faults, replace the touch overlay panel.

    PROFINET communication is lost intermittently

    Check the RJ45 cable integrity and connector seating. Use a network diagnostic tool to monitor packet loss and verify the IP address configuration of the panel PC.

    Replace the Ethernet cable with a shielded industrial-grade cable. Verify PROFINET device name and IP settings match the controller configuration. Check for IP address conflicts on the network.

    Panel PC fails to boot and displays a POST error

    Observe the error message displayed during POST. Check whether the storage device (SSD or CF card) is detected in the BIOS setup menu.

    Re-seat the storage device and attempt to boot again. If the device is not detected, replace it with a compatible Siemens-approved storage medium and restore the OS image using the Siemens recovery tool.

    Unit operates at high temperature and shuts down unexpectedly

    Monitor the CPU and enclosure temperature using the SIMATIC IPC DiagMonitor tool or BIOS hardware monitor. Check that ambient temperature is within the 0 to 50 °C operating range.

    Ensure adequate ventilation clearance around the panel cutout. Clean any dust from vents or heat spreader surfaces. If operating in high-ambient environments, consider adding external cooling or relocating the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart