• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6648-0CE1-3AX0 SIMATIC KTP600 Basic
    Awaiting product image

    Siemens 6AV6648-0CE1-3AX0 SIMATIC KTP600 Basic

    € 547,00

    Reset
    Clear
    SKU: 6AV6648-0CE1-3AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6648-0CE1-3AX0 is a KTP600 Basic Color PN panel belonging to the SIMATIC Basic Panel family. It is a compact human-machine interface (HMI) device featuring a 5.7-inch TFT color display combined with key-and-touch operation, designed for straightforward machine-level visualization tasks. This unit is part of Siemens' entry-level HMI portfolio and is configured and operated using the SIMATIC WinCC Basic engineering software included with TIA Portal.

    The panel features a 5.7-inch TFT display with a resolution of 320 x 240 pixels (QVGA) and supports 256 colors. It integrates a PROFINET interface for communication with SIMATIC S7-1200 and S7-300/400 PLCs, as well as other PROFINET-compatible controllers. The device offers 10 MB of user memory, supports up to 500 tags, and includes 6 configurable function keys in addition to its resistive touch screen. The unit operates on 24 V DC supply voltage and carries CE and UL certifications.

    The KTP600 Basic Color PN is widely used in manufacturing, packaging, and process automation applications where a cost-effective, reliable HMI solution is required at the machine level. Its compact form factor and PROFINET connectivity make it suitable for integration into small to medium-sized control panels in industries such as food and beverage, automotive assembly, and material handling. The combination of touch and function key operation provides flexibility for operator interaction in environments where gloved operation may be required.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels (QVGA)
    Display Colors 256 colors
    Display Type TFT
    Touch Technology Resistive touch screen
    Function Keys 6
    Input/Operating Voltage 24 V DC
    Power Consumption 6 W (typical)
    Communication Interface PROFINET (RJ45)
    User Memory 10 MB
    Number of Tags 500 (maximum)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software SIMATIC WinCC Basic (TIA Portal)

    Common Error Codes and System Events

    Event ID: 10000
    Configuration error detected on the HMI panel; the project loaded does not match the target device type or version.
    Verify that the correct device type and firmware version are selected in TIA Portal. Re-download the project to the panel after correcting the configuration.
    Event ID: 20000
    Communication connection to the PLC has been lost or cannot be established.
    Check PROFINET cable connections and network settings. Verify that the PLC IP address configured in the HMI project matches the actual PLC address. Check PLC operating state.
    Event ID: 40000
    Tag acquisition error; one or more tags cannot be read from the connected controller.
    Verify that the tag addresses in the HMI project correspond to valid addresses in the PLC program. Check PLC data block and variable configurations.
    Event ID: 50000
    System memory low warning; available user memory on the panel is critically low.
    Review the HMI project for unnecessary graphics, scripts, or archived data. Reduce project size and re-download to the device.
    Event ID: 70000
    Firmware update error; firmware transfer to the panel was interrupted or failed.
    Restart the firmware update procedure using ProSave or TIA Portal. Ensure stable USB or PROFINET connection during the update process and do not interrupt power.
    Event ID: 3000
    Operator input rejected; a touch or key input was made outside a valid input field or during a protected state.
    Check screen configuration for correct input field placement and access protection settings. Verify that the correct user authorization level is active.
    Event ID: 60000
    Recipe data error; a recipe record could not be read or written correctly.
    Check recipe configuration in the project. Verify that recipe tag addresses are valid and that sufficient memory is available for recipe storage.

    Frequently Asked Questions

    Which PLCs are compatible with the KTP600 Basic Color PN (6AV6648-0CE1-3AX0)?

    The KTP600 Basic Color PN is primarily designed for use with SIMATIC S7-1200 PLCs and also supports S7-300 and S7-400 controllers via PROFINET. It can also communicate with other PROFINET-capable controllers supported by TIA Portal WinCC Basic.

    What engineering software is required to configure this panel?

    The panel is configured using SIMATIC WinCC Basic, which is included with the TIA Portal engineering framework. A standalone version of WinCC Basic or higher is required to create and download projects to this device.

    What is the supply voltage for the 6AV6648-0CE1-3AX0?

    The panel requires a 24 V DC supply voltage. Ensure the power supply is within the permissible tolerance range as specified in the device manual.

    Can the KTP600 Basic panel be operated with gloves?

    Yes, the panel includes 6 physical function keys in addition to the resistive touch screen, allowing operation with gloves where touch screen sensitivity may be reduced.

    What is the front panel protection rating of this HMI?

    The front panel of the KTP600 Basic Color PN carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check that polarity is correct and voltage is within the specified range.

    Correct any wiring errors or supply voltage issues. If voltage is correct and the display remains blank, the internal power supply or backlight may be faulty and the unit should be inspected for repair or replacement.

    Panel cannot establish communication with the PLC

    Check the PROFINET cable connection and verify the IP address settings on both the HMI panel and the PLC. Use a network scanner or TIA Portal to confirm both devices are visible on the network.

    Correct IP address conflicts or subnet mismatches in the project configuration. Replace the PROFINET cable if damaged. Ensure the PLC is in RUN mode and the PROFINET interface is enabled.

    Touch screen does not respond to input or responds inaccurately

    Check for physical damage or contamination on the touch screen surface. Attempt to recalibrate the touch screen through the panel's Start Center or control panel settings.

    Clean the touch screen surface with a soft, dry cloth. Perform a touch screen recalibration via the operating system settings. If the problem persists, the touch screen digitizer may require replacement.

    Project download from TIA Portal fails or times out

    Verify the PROFINET connection between the engineering PC and the HMI panel. Check that the panel is in transfer mode and that firewall or antivirus software is not blocking the TIA Portal communication.

    Set the panel to transfer mode via the Start Center. Disable any firewall rules blocking TIA Portal on the engineering PC. Ensure the correct network adapter is selected in TIA Portal's device settings.

    Panel repeatedly restarts or shows a loading screen loop

    This may indicate a corrupted project file or a firmware mismatch. Connect to the panel using ProSave to check firmware version and attempt to restore or re-download the project.

    Use ProSave to perform a firmware update or restore the panel to factory defaults. Re-download a verified project from TIA Portal. If the issue persists, the panel's internal flash memory may be faulty.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart