Siemens 6AV6647-0AK11-3AX1 KTP600 Basic
€ 378,00
The Siemens 6AV6647-0AK11-3AX1 is a KTP600 Basic Color PN panel belonging to the SIMATIC HMI Basic Panel series. It features a 5.7-inch TFT color display and is designed for straightforward machine-level visualization tasks. This panel is part of Siemens' entry-level HMI lineup, offering a compact and cost-effective solution for basic operator interface requirements.
The KTP600 Basic Color PN is equipped with a PROFINET interface for integration into modern Ethernet-based automation networks, enabling communication with SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs. The panel combines a resistive touch screen with 6 configurable function keys, providing flexible operator input options. It supports 256 colors on its TFT display at a resolution of 320 x 240 pixels and is configured using the WinCC flexible Compact or TIA Portal WinCC Basic engineering software.
The KTP600 Basic Color PN is widely deployed in manufacturing, packaging, and process automation applications where a compact, network-connected HMI is required at the machine level. Its PROFINET connectivity makes it suitable for integration into distributed I/O architectures and modern production lines. The panel's small footprint and panel-mount design allow installation in standard control cabinets and machine enclosures across industries such as food and beverage, automotive, and general machinery.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Colors | 256 colors |
| Display Type | TFT LCD |
| Touch Technology | Resistive touch screen |
| Function Keys | 6 configurable function keys |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 6 W (typical) |
| Communication Interface | PROFINET (RJ45, 10/100 Mbit/s) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Dimensions (W x H x D) | 196 x 141 x 45 mm |
| Panel Cutout | 186 x 131 mm |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI Basic Panel |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error: The project loaded on the panel is incompatible or corrupt.
Re-download the project from TIA Portal or WinCC flexible. Verify the project was compiled without errors before transfer. - Event ID: 20000
- Communication error: Connection to the configured PLC cannot be established.
Check PROFINET cable and RJ45 connector integrity. Verify IP address settings on both the panel and the PLC. Ensure the PLC is in RUN mode. - Event ID: 40000
- Tag read/write error: A process tag could not be read from or written to the PLC.
Verify the tag address in the project configuration matches the actual PLC data block or memory area. Check PLC program for address conflicts. - Event ID: 50000
- System memory low: Available memory on the HMI device is insufficient to load all configured objects.
Reduce the number of images, variables, or alarms in the project. Archive or delete unused data logs and alarm logs stored on the device. - Event ID: 60000
- Backup/restore error: A backup or restore operation failed to complete successfully.
Check the USB storage medium for sufficient free space and correct formatting (FAT32). Retry the operation or use a different USB device. - Event ID: 70000
- Operating system error: An internal OS fault has been detected on the HMI panel.
Perform a controlled restart of the panel. If the fault persists, perform a factory reset via the Start Center and reload the project. - Event ID: 30000
- License error: A required software option or runtime license is missing or invalid.
Verify that the correct WinCC runtime license is installed on the device. Transfer the appropriate license using the Automation License Manager.
Frequently Asked Questions
Which engineering software is used to configure the KTP600 Basic Color PN?
The KTP600 Basic Color PN (6AV6647-0AK11-3AX1) can be configured using Siemens TIA Portal with WinCC Basic or the legacy WinCC flexible Compact software. TIA Portal is the recommended tool for new projects.
Which PLCs are compatible with this HMI panel?
The panel supports PROFINET communication and is compatible with SIMATIC S7-1200, S7-1500, S7-300, and S7-400 PLCs. Compatibility with third-party controllers via PROFINET is limited and should be verified against the device documentation.
What is the supply voltage for the 6AV6647-0AK11-3AX1?
The panel requires a 24 V DC supply voltage. The permissible voltage range is typically 19.2 V DC to 28.8 V DC.
Does this panel support data logging or alarm logging?
Yes, the KTP600 Basic supports alarm logging and data logging functions, with logs stored in internal memory. The capacity is limited compared to higher-tier SIMATIC panels, so log sizes should be managed within the project configuration.
What is the IP protection rating of the KTP600 Basic Color PN?
The front face of the panel is rated IP65, making it suitable for installation in environments where dust and water jets may be present. The rear of the panel is rated IP20.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel's power connector. Check that the voltage is within the 19.2–28.8 V DC range. Inspect the power supply unit and wiring for faults.
Correct any supply voltage issues. If the supply voltage is correct and the display remains blank, the internal backlight or power supply board may be faulty and the unit should be sent for repair or replacement.
Panel cannot establish communication with the PLC via PROFINET
Verify the IP address configuration on both the HMI panel (via Start Center > Settings > Network) and the PLC. Check the RJ45 cable and switch/hub connections. Use a network scanner to confirm the panel is visible on the network.
Assign correct and unique IP addresses to both devices within the same subnet. Replace the Ethernet cable if damaged. Ensure the PROFINET device name configured in the project matches the name assigned to the panel.
Touchscreen does not respond or responds inaccurately to touch input
Check whether the function keys still respond, which would indicate the touch layer is the issue rather than the entire panel. Inspect the display surface for damage, contamination, or excessive pressure points.
Perform a touchscreen calibration via the Start Center on the panel. Clean the display surface with a soft, dry cloth. If calibration does not resolve the issue, the touch foil or controller board may require replacement.
Project download from TIA Portal fails or times out
Verify the PC and HMI panel are on the same network subnet and that no firewall is blocking the connection. Confirm the panel is in Transfer mode (accessible via Start Center > Transfer).
Set the panel to Transfer mode before initiating the download. Disable any PC firewall temporarily during transfer. Ensure the TIA Portal project is compiled without errors before attempting the download.
Panel displays 'No project' or reverts to Start Center after restart
This indicates the project was not successfully stored in the panel's internal flash memory, or the project was deleted. Check if the project download completed without errors.
Re-download the project from TIA Portal or WinCC flexible, ensuring the transfer completes fully before powering off the panel. Verify that sufficient internal memory is available on the device before transfer.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page