• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6646-1BD15-0AA0 SIMATIC KTP1500 Basic
    Awaiting product image

    Siemens 6AV6646-1BD15-0AA0 SIMATIC KTP1500 Basic

    € 872,00

    Reset
    Clear
    SKU: 6AV6646-1BD15-0AA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6646-1BD15-0AA0 is a SIMATIC KTP1500 Basic Panel, part of the Siemens SIMATIC HMI Basic Panel series. It is a 15-inch key and touch combination operator panel designed for machine-level visualization and operator control tasks. This panel is engineered for straightforward HMI applications requiring a large, clear display with reliable touch and key input.

    The KTP1500 Basic features a 15.6-inch widescreen TFT display with a resolution of 1366 x 768 pixels and 65,536 colors, providing sharp and detailed process visualization. It supports PROFINET communication as its primary interface, enabling seamless integration with Siemens S7-1200 and S7-1500 PLC families. The panel is configured using WinCC Basic (TIA Portal) engineering software and offers 12 configurable function keys for direct operator input. It operates on 24 V DC supply voltage and is rated IP65 on the front face for protection against dust and water ingress.

    The SIMATIC KTP1500 Basic is widely used in machine building, packaging machinery, conveyor systems, and general industrial automation applications. Its large display area makes it particularly suitable for applications requiring simultaneous visualization of multiple process parameters or graphical overviews. The combination of touch and physical function keys provides operators with flexible and reliable control options in demanding production environments.

    Technical Specifications

    Display Size 15.6 inch
    Display Resolution 1366 x 768 pixels
    Display Colors 65,536 (16-bit)
    Display Type TFT widescreen
    Touch Technology Resistive touch screen with 8 function keys
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 30 W
    Communication Interface PROFINET (1x RJ45)
    Configuration Software WinCC Basic V13 or higher (TIA Portal)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI Basic Panel

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected on startup; the project loaded on the panel does not match the connected PLC or is corrupted.
    Re-download the project from TIA Portal to the panel. Verify PLC type and firmware compatibility.
    Event ID: 10001
    Communication connection to the PLC has been lost or cannot be established.
    Check PROFINET cable and connections. Verify IP address configuration on both panel and PLC. Ensure PLC is in RUN mode.
    Event ID: 20000
    System memory low warning; available runtime memory is critically low.
    Reduce the number of active screens or objects. Optimize the project configuration in TIA Portal and reload.
    Event ID: 40000
    Backup/restore error; a backup or restore operation failed to complete successfully.
    Check the integrity of the backup file. Ensure sufficient storage is available and retry the operation.
    Event ID: 50000
    Firmware update error; the firmware update process was interrupted or failed.
    Retry the firmware update using the correct firmware version via TIA Portal or the Automation Tool. Do not power off during update.
    Event ID: 60000
    Tag address invalid; a configured tag address cannot be found or is out of range in the connected PLC.
    Verify tag addresses in the TIA Portal project. Ensure PLC program matches the HMI tag configuration and re-download.
    Event ID: 70000
    Screen object error; one or more screen objects failed to render due to missing or invalid references.
    Check the project in TIA Portal for missing images, scripts, or broken object references. Recompile and re-download the project.

    Frequently Asked Questions

    Which PLCs are compatible with the KTP1500 Basic (6AV6646-1BD15-0AA0)?

    The KTP1500 Basic is primarily designed for use with Siemens S7-1200 and S7-1500 PLCs via PROFINET. It can also communicate with S7-300 and S7-400 PLCs using appropriate configuration in TIA Portal.

    What software is required to configure the KTP1500 Basic?

    The panel is configured using Siemens WinCC Basic, which is included in the TIA Portal engineering framework. A minimum of TIA Portal V13 is required, with later versions recommended for full feature support.

    What is the supply voltage for the 6AV6646-1BD15-0AA0?

    The panel requires a 24 V DC power supply. Ensure the supply is within the permissible tolerance range, typically 19.2 V DC to 28.8 V DC.

    Does the KTP1500 Basic support USB connectivity?

    Yes, the KTP1500 Basic includes a USB interface that can be used for project transfer, firmware updates, and connecting USB peripherals such as barcode scanners or keyboards.

    What is the front panel protection rating of the KTP1500 Basic?

    The front face of the KTP1500 Basic is rated IP65, making it resistant to dust and low-pressure water jets. The rear of the unit is rated IP20.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply terminals. Measure voltage at the panel connector to confirm supply is within range. Inspect for any blown internal fuse.

    Ensure the power supply provides stable 24 V DC within the 19.2–28.8 V DC tolerance. If voltage is correct and display remains blank, the panel may require repair or replacement of the internal display backlight or power board.

    Panel cannot establish communication with the PLC

    Verify the PROFINET cable is securely connected to the RJ45 port. Check IP address settings on both the panel and the PLC using TIA Portal. Confirm the PLC is in RUN mode and the network configuration matches.

    Assign correct and unique IP addresses to both devices within the same subnet. Re-download the project from TIA Portal. Replace the Ethernet cable if physical damage is suspected.

    Touchscreen does not respond or responds inaccurately

    Check for physical damage or contamination on the touch surface. Determine if the issue is consistent across the entire screen or localized to specific areas.

    Clean the screen surface with a soft, dry cloth. If inaccuracy persists, perform a touch calibration via the panel's Start Center. If the touch layer is damaged, the panel front assembly may need replacement.

    Project fails to load or panel displays configuration error on startup

    Confirm the project was compiled without errors in TIA Portal before transfer. Check that the firmware version on the panel is compatible with the TIA Portal version used to create the project.

    Update the panel firmware to the version required by the TIA Portal project. Recompile the project and re-download it to the panel via PROFINET or USB.

    Function keys do not respond when pressed

    Check the project configuration in TIA Portal to confirm function key events are correctly assigned. Test whether the issue occurs with all keys or specific ones.

    Verify function key assignments in the TIA Portal project and re-download. If specific keys are physically unresponsive, the keypad membrane may be worn or damaged and require hardware replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart