Siemens 6AV6545-5FC10-0CK0 Mobile Panel 177
€ 1.283,00
The Siemens 6AV6545-5FC10-0CK0 is a Mobile Panel 177 belonging to the SIMATIC HMI product family. It is a portable, handheld operator panel designed for flexible machine-level operation and monitoring in industrial environments. This unit provides a 5.7-inch TFT color display and is intended for use with Siemens SIMATIC controllers via PROFIBUS or MPI communication.
The Mobile Panel 177 features a 5.7-inch TFT display with 256-color support and a resolution of 320 x 240 pixels (QVGA). It is equipped with a membrane keypad with function keys, an integrated enabling button (three-position), and an emergency stop button, making it suitable for safety-relevant operator interactions. The panel supports MPI and PROFIBUS DP communication interfaces and is configured using WinCC flexible engineering software. It includes 512 KB user memory and operates from a 24 V DC power supply delivered via the connecting cable.
The Mobile Panel 177 is widely used in machine building, automotive manufacturing, and process industries where operators need to move freely around a machine or production line during setup, commissioning, or maintenance tasks. Its integrated safety features — including the three-position enabling switch and emergency stop — make it suitable for applications requiring safe manual intervention near moving machinery. The rugged housing and portable design allow reliable operation in demanding shop-floor environments.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Colors | 256 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC (via connecting cable) |
| Communication Interface | MPI, PROFIBUS DP |
| User Memory | 512 KB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front) |
| Safety Features | Three-position enabling button, Emergency stop button |
| Engineering Software | WinCC flexible 2005 or higher |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Mobile Panel 177 |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the Mobile Panel and the connected PLC. The panel cannot establish or maintain a connection via MPI or PROFIBUS DP.
Check the cable connection and connector integrity. Verify the MPI/PROFIBUS address settings on both the panel and the PLC. Ensure the baud rate is correctly configured in WinCC flexible. - Event ID: 20000
- Project download error. A fault occurred during the transfer of the project from the engineering PC to the Mobile Panel.
Check the transfer cable and PC interface settings. Ensure WinCC flexible version is compatible with the panel firmware. Retry the download after restarting both the panel and the engineering PC. - Event ID: 40000
- System memory overflow. The panel's user memory has been exceeded by the loaded project.
Reduce the project size by optimizing graphics, removing unused tags, or compressing images. Verify that the project is compiled for the correct panel type and memory configuration. - Event ID: 50000
- Tag update error. One or more process tags cannot be read from or written to the connected controller.
Verify PLC program is running and the relevant data blocks or addresses are accessible. Check tag addressing in WinCC flexible for correctness. Confirm communication is active and not interrupted. - Event ID: 70000
- Enabling button not actuated. The three-position enabling switch is not in the active (middle) position, preventing operation in enabling-required mode.
Ensure the operator is correctly pressing the enabling button to the middle position. If the button is faulty or not responding, inspect the enabling switch mechanism and replace the panel if the switch is defective. - Event ID: 80000
- Emergency stop activated. The integrated emergency stop button on the Mobile Panel has been pressed.
Identify and resolve the cause of the emergency stop activation. Reset the emergency stop button by rotating it to release, then acknowledge the fault on the controller before resuming operation. - Event ID: 30000
- Firmware update error. An error occurred during a firmware update of the Mobile Panel.
Restart the panel and attempt the firmware update again using the correct firmware version for the 6AV6545-5FC10-0CK0. Ensure the ProSave tool or WinCC flexible is used correctly and the panel is not powered off during the update process.
Frequently Asked Questions
What communication interfaces does the Mobile Panel 177 (6AV6545-5FC10-0CK0) support?
The Mobile Panel 177 supports MPI and PROFIBUS DP communication interfaces. It connects to SIMATIC S7 controllers via these protocols through the panel's connecting cable.
Which engineering software is required to configure this Mobile Panel?
The 6AV6545-5FC10-0CK0 is configured using Siemens WinCC flexible 2005 or a later compatible version. Projects are created on a PC and downloaded to the panel via the connecting cable.
Does this Mobile Panel include safety features for use near moving machinery?
Yes, the Mobile Panel 177 includes an integrated three-position enabling button and an emergency stop button. These features allow it to be used in safety-relevant applications where controlled manual intervention near moving parts is required.
What is the display size and resolution of the 6AV6545-5FC10-0CK0?
The panel features a 5.7-inch TFT color display with a resolution of 320 x 240 pixels (QVGA) and supports 256 colors.
What is the operating voltage for this Mobile Panel?
The Mobile Panel 177 operates at 24 V DC, which is supplied through the connecting cable rather than a separate power connector on the panel itself.
Troubleshooting
Display remains blank after connection and power-on
Check that 24 V DC is being correctly supplied through the connecting cable. Measure voltage at the cable connector. Inspect the cable for damage or broken wires.
Replace the connecting cable if voltage is absent or intermittent at the panel end. If voltage is confirmed correct and the display remains blank, the internal power supply or display unit may be faulty and the panel should be sent for repair.
No communication with the PLC via PROFIBUS DP or MPI
Verify the PROFIBUS or MPI address configured in WinCC flexible matches the address set on the panel. Check the cable and connectors for continuity and correct pin assignment. Confirm the PLC is in RUN mode.
Correct any address mismatches in the project configuration and re-download the project. Replace the connecting cable if physical damage is found. Ensure termination resistors are correctly set on the PROFIBUS network.
Enabling button does not respond or is not recognized by the system
Test the three-position enabling switch by observing the panel's response when the button is pressed to the middle position. Check if the connected safety circuit or PLC input registers the enabling signal.
If the enabling switch is mechanically damaged or produces no signal, the Mobile Panel must be repaired or replaced, as the enabling switch is an integrated safety component and cannot be easily serviced in the field.
Emergency stop button cannot be reset after activation
Confirm the emergency stop button has been physically released by rotating it in the direction indicated on the button. Check the safety relay or PLC input connected to the emergency stop circuit for correct wiring.
Rotate and release the emergency stop button fully, then send a reset command from the controller or HMI as required by the machine's safety logic. If the button remains latched or does not release, inspect the button mechanism for mechanical damage and replace the panel if necessary.
Project download fails or transfer is interrupted
Check the transfer cable between the engineering PC and the Mobile Panel. Verify that the panel is set to Transfer mode before initiating the download. Confirm WinCC flexible project is compiled without errors.
Restart both the panel (in Transfer mode) and the engineering PC, then retry the download. Use the correct transfer cable for MPI/PROFIBUS. If the issue persists, update the panel firmware using ProSave and attempt the project download again.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page