Siemens 6AV6470-1XA20 SIMATIC ProTool/Pro
€ 583,00
The Siemens 6AV6470-1XA20 is a software package belonging to the SIMATIC ProTool/Pro product family, developed by Siemens for configuring and programming HMI (Human-Machine Interface) panels and operator devices. This software is part of the SIMATIC HMI engineering toolset and is used to create visualization projects for operator panels such as the OP, TP, and MP series devices. It serves as a project engineering tool that enables users to design screens, configure tags, and define communication links between HMI devices and PLCs.
ProTool/Pro provides a Windows-based engineering environment supporting the configuration of text-based and graphical operator panels within the SIMATIC HMI portfolio. The software supports communication with SIMATIC S5, S7, and third-party controllers via standard interfaces such as MPI, PROFIBUS DP, and serial connections. It includes libraries of standard objects, alarm management tools, recipe management, and trend display configuration capabilities. The software generates project data that is downloaded directly to compatible HMI hardware targets.
The 6AV6470-1XA20 software is widely used in manufacturing, process automation, and machine building environments where SIMATIC operator panels are deployed for local machine control and monitoring. It is particularly suited for retrofitting or maintaining existing installations that use legacy SIMATIC HMI hardware such as the OP7, OP17, OP27, OP37, and TP series panels. Engineers and system integrators working with established SIMATIC infrastructures rely on this tool to maintain and extend existing HMI projects without migrating to newer platforms.
Technical Specifications
| Software Type | HMI Engineering / Configuration Software |
|---|---|
| Product Family | SIMATIC ProTool/Pro |
| Target HMI Devices | SIMATIC OP, TP, MP series operator panels |
| Supported Controllers | SIMATIC S5, S7, third-party PLCs |
| Communication Interfaces | MPI, PROFIBUS DP, Serial (RS-232/RS-422/RS-485) |
| Operating System | Windows (32-bit) |
| License Type | Single-user software license |
| Project Transfer | Serial, MPI, PROFIBUS DP |
| Alarm Management | Supported |
| Recipe Management | Supported |
| Trend Display Configuration | Supported |
| Certifications | CE |
Common Error Codes and Software Events
- Configuration Error
- Project configuration contains invalid or missing tag assignments, preventing successful compilation.
Review all tag links in the project editor, correct missing PLC variable references, and recompile the project. - Communication Error
- ProTool/Pro cannot establish a connection to the target HMI device during project download.
Verify the correct communication interface is selected, check cable connections, and confirm the HMI device is powered and in transfer mode. - Transfer Error
- Project download to the HMI panel was interrupted or failed to complete.
Check the transfer cable integrity, ensure the correct COM port or MPI address is configured, and retry the download. - Incompatible Device Error
- The selected target HMI device type in the project does not match the connected physical device.
Verify the device type setting in the project properties matches the actual hardware model and firmware version. - License Error
- Software license not found or has expired, preventing the application from launching or saving projects.
Check the license dongle is connected (if applicable), verify the license installation using the Siemens license manager, and reinstall if necessary. - Compilation Error
- Project compilation fails due to syntax errors, unsupported functions, or resource limits exceeded on the target device.
Review the compiler output log, resolve flagged errors in screen objects or tag configurations, and ensure project resource usage is within the target device limits. - Version Mismatch Warning
- The project file was created with a different version of ProTool/Pro than the currently installed version.
Upgrade the project using the migration function within ProTool/Pro or install the matching software version to ensure compatibility.
Frequently Asked Questions
Which HMI devices are compatible with the Siemens 6AV6470-1XA20 ProTool/Pro software?
ProTool/Pro supports SIMATIC operator panels including the OP7, OP17, OP27, OP37, TP27, TP37, and related MP series devices. Compatibility depends on the specific software version installed.
What communication protocols does ProTool/Pro support for PLC connectivity?
The software supports MPI, PROFIBUS DP, and serial interfaces (RS-232, RS-422, RS-485) for communication with SIMATIC S5, S7, and compatible third-party controllers.
Can ProTool/Pro projects be migrated to WinCC flexible or TIA Portal?
Siemens provides migration tools within WinCC flexible and TIA Portal that can import ProTool/Pro projects, though some manual rework may be required depending on the complexity of the original project.
Is a hardware dongle required to run ProTool/Pro?
Depending on the license variant, ProTool/Pro may require a hardware license dongle (SIMATIC Automation License Manager key). Check the specific license type supplied with the 6AV6470-1XA20 package.
On which operating systems can ProTool/Pro be installed?
ProTool/Pro is designed for 32-bit Windows operating systems. It is not natively compatible with 64-bit versions of Windows, and a virtual machine or compatibility layer may be required for modern systems.
Troubleshooting
ProTool/Pro fails to install on a modern Windows PC
The software is designed for 32-bit Windows environments and may not install correctly on 64-bit Windows 7, 8, or 10 systems due to compatibility restrictions.
Install ProTool/Pro on a dedicated 32-bit Windows XP or Windows 2000 machine, or use a virtual machine running a compatible 32-bit Windows OS to host the software.
Project download to HMI panel fails with a communication error
Check the physical connection between the PC and the HMI panel. Verify the correct serial COM port or MPI adapter is selected in the transfer settings and that the HMI is set to transfer mode.
Ensure the correct PC/PPI or MPI adapter is used, confirm the baud rate and address settings match on both sides, and restart the HMI in transfer mode before retrying the download.
Software reports a license error on startup
The license dongle may not be connected, the license may not be correctly installed, or the Siemens Automation License Manager may not recognize the license.
Connect the hardware license dongle if required, open the Siemens Automation License Manager to verify license status, and reinstall the license if it is not detected.
Compiled project exceeds target device memory limits
The project contains too many screens, tags, or graphical objects for the selected HMI target device, causing the compiler to report resource overflow errors.
Reduce the number of screens, optimize graphics by using fewer bitmap images, consolidate tags, and verify that the project is configured for the correct target device with its actual memory capacity.
Existing ProTool/Pro project file cannot be opened after software reinstallation
The project file version may not match the installed ProTool/Pro version, or project files may have become corrupted.
Use the project migration function if available, restore the project from a backup, or install the matching ProTool/Pro version that was originally used to create the project.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page