• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-7BA40-1BY4 SIMATIC MP 370
    Awaiting product image

    Siemens 6AV6446-7BA40-1BY4 SIMATIC MP 370

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6446-7BA40-1BY4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-7BA40-1BY4 is a Multi Panel (MP 370) belonging to the SIMATIC HMI family, designed for high-performance human-machine interface applications in industrial automation environments. This panel features a 15-inch TFT display and is part of Siemens' advanced operator panel series, offering robust visualization and control capabilities. It is engineered to operate reliably in demanding industrial conditions and integrates seamlessly with Siemens SIMATIC controller platforms.

    The MP 370 panel is equipped with a high-resolution 15-inch TFT color display with a resolution of 1024 x 768 pixels, supporting 64,000 colors for clear process visualization. It features both touch screen and key-based operation, providing flexible operator interaction. The unit supports multiple communication interfaces including MPI, PROFIBUS DP, and Ethernet (TCP/IP), enabling integration into a wide range of automation network architectures. Configured using Siemens WinCC flexible engineering software, the panel offers substantial project memory and supports a variety of scripting and alarm management functions.

    The SIMATIC MP 370 is widely deployed in manufacturing, process automation, energy management, and machine building industries where large-format, high-resolution visualization is required. Its combination of touch and key operation makes it suitable for complex control panels in automotive production lines, chemical processing plants, and packaging machinery. The panel's robust construction and broad communication capability make it a reliable choice for both standalone HMI applications and networked SCADA-level visualization tasks.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Touch Technology Resistive touchscreen with function keys
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 60 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (TCP/IP), RS-422/485
    Memory 12 MB project memory (Flash)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front), IP20 (rear)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI Multi Panel MP 370

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC controller. Connection to the configured PLC address cannot be established.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings in WinCC flexible match the hardware configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Connection to PLC lost during runtime operation.
    Inspect communication cables for damage or loose connectors. Check network topology and bus termination. Restart the HMI panel and verify PLC is operational.
    Event ID: 20000
    Project download error. Transfer of project data from engineering PC to the panel failed.
    Verify the transfer cable or Ethernet connection between the PC and panel. Ensure the panel is in Transfer mode. Check that WinCC flexible version is compatible with the panel firmware version.
    Event ID: 40000
    System memory low. Available project or runtime memory is critically low.
    Delete unused project data, archived logs, or recipe files from the panel memory. Consider optimizing the project size in WinCC flexible and re-downloading.
    Event ID: 50000
    Panel firmware version mismatch detected. The loaded project was created with an incompatible version of WinCC flexible.
    Update the panel firmware to match the WinCC flexible version used to create the project, or recompile and download the project using a compatible software version.
    Event ID: 70000
    Touchscreen calibration error. Touch input is not registering correctly or is misaligned.
    Perform a touchscreen recalibration via the panel's Start Center or Control Panel settings. If calibration fails repeatedly, the touchscreen hardware may require replacement.
    Event ID: 80000
    Internal temperature warning. The panel's internal operating temperature has exceeded the recommended threshold.
    Check that the installation environment does not exceed 50 °C. Ensure adequate ventilation around the panel. Clean any dust from ventilation openings and verify the installation orientation.

    Frequently Asked Questions

    What communication interfaces does the SIMATIC MP 370 (6AV6446-7BA40-1BY4) support?

    The MP 370 supports MPI, PROFIBUS DP, Ethernet (TCP/IP), and RS-422/485 serial interfaces, allowing connection to a wide range of Siemens and third-party controllers.

    Which engineering software is used to configure and program this panel?

    The panel is configured using Siemens WinCC flexible, which provides project creation, tag management, alarm configuration, and project download functionality for the MP 370 series.

    Is the MP 370 compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the MP 370 is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP, and can also communicate with S7 controllers over Ethernet using TCP/IP.

    What is the operating voltage for this HMI panel?

    The panel operates on 24 V DC, which is the standard supply voltage for SIMATIC HMI panels in industrial control cabinet installations.

    What is the front panel protection rating of the MP 370?

    The front of the panel is rated IP65, making it protected against dust ingress and low-pressure water jets, suitable for installation in industrial control panels.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel's power connector. Check for blown internal fuses or a faulty power supply unit. Verify the power cable is correctly wired and making good contact.

    Correct any wiring errors and ensure the supply voltage is within the 24 V DC tolerance range. Replace any blown fuses. If the power supply module is faulty, the panel will require internal repair or replacement of the power supply board.

    Panel fails to communicate with the PLC via PROFIBUS DP

    Check the PROFIBUS cable for correct termination at both ends of the bus segment. Verify the panel's PROFIBUS address in WinCC flexible matches the hardware configuration. Use a PROFIBUS diagnostic tool to check bus integrity.

    Correct bus termination by enabling termination resistors only at the physical ends of the PROFIBUS segment. Correct the address settings in the WinCC flexible project and re-download. Replace damaged PROFIBUS cables or connectors as needed.

    Touchscreen does not respond or responds inaccurately to touch input

    Attempt a touchscreen recalibration from the panel's Start Center or Control Panel. Check for physical damage, contamination, or excessive pressure marks on the touchscreen surface.

    Perform a full touchscreen recalibration. Clean the screen surface with a soft, dry cloth. If calibration fails or the screen remains unresponsive, the touchscreen assembly may need to be replaced.

    Project download from WinCC flexible fails or times out

    Verify the Ethernet or MPI/PC adapter cable connection between the engineering PC and the panel. Confirm the panel is set to Transfer mode via the Start Center. Check firewall or antivirus software on the PC that may be blocking the transfer.

    Switch the panel to Transfer mode manually. Disable any PC firewall rules blocking the WinCC flexible transfer port. Use a known-good cable and verify the correct communication channel is selected in WinCC flexible's transfer settings.

    Panel repeatedly reboots or freezes during runtime

    Check the 24 V DC supply for voltage dips or instability under load. Review the panel's system log for recurring event IDs. Inspect the project for memory overload or script errors that may cause runtime crashes.

    Stabilize the power supply by using a dedicated 24 V DC source with adequate current capacity. Optimize the WinCC flexible project to reduce memory usage. Update the panel firmware to the latest compatible version to resolve known runtime stability issues.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart