• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-3BA41-0BY4 SIMATIC MP 370
    Awaiting product image

    Siemens 6AV6446-3BA41-0BY4 SIMATIC MP 370

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6446-3BA41-0BY4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-3BA41-0BY4 is a Multi Panel (MP 370) belonging to the SIMATIC HMI family, designed for demanding visualization and operator control tasks in industrial automation environments. This panel features a 15-inch TFT display and is part of the SIMATIC MP 370 series, which represents a high-performance class of operator panels capable of running WinCC flexible runtime software. The unit is manufactured by Siemens and combines robust hardware with versatile communication capabilities for use in complex machine and plant visualization applications.

    The MP 370 (6AV6446-3BA41-0BY4) is equipped with a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA), providing clear and detailed process visualization. The panel supports touch screen operation and includes a range of communication interfaces such as PROFIBUS DP, MPI, and Ethernet (TCP/IP), enabling integration with a wide variety of Siemens and third-party controllers. It runs on a Windows CE operating system and supports WinCC flexible runtime, allowing for sophisticated HMI projects with scripting, alarms, trends, and recipe management. The unit operates on a 24 V DC supply and is rated to IP65 at the front panel, ensuring protection against dust and water ingress in industrial environments.

    The SIMATIC MP 370 is widely deployed in machine building, automotive manufacturing, process industries, and plant engineering where large-format, high-resolution visualization is required. Its multi-protocol communication support makes it suitable for integration into existing SIMATIC S7 automation architectures as well as mixed-vendor environments. The panel's robust construction and broad software compatibility make it a reliable choice for central operator stations on complex production lines and process control systems.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Colors 64,000 colors (TFT)
    Touch Technology Resistive touch screen
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 40 W
    Operating System Windows CE
    Communication Interface PROFIBUS DP, MPI, Ethernet (TCP/IP), RS-422/485
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC MP 370

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC or controller. The connection has been interrupted or cannot be established.
    Check the communication cable and connector integrity. Verify the MPI/PROFIBUS address settings on both the panel and the PLC. Ensure the PLC is in RUN mode and the network configuration matches the project settings.
    Event ID: 10001
    Connection to the configured PLC has timed out. The panel cannot reach the controller within the expected time window.
    Verify network cabling and termination resistors on PROFIBUS. Check that the PLC address and baud rate configured in WinCC flexible match the actual hardware settings. Restart both the panel and the PLC if necessary.
    Event ID: 20000
    Project download error. The transfer of the HMI project from the engineering PC to the panel has failed.
    Ensure the panel is in Transfer mode before initiating the download. Check the transfer cable or Ethernet connection. Verify that the WinCC flexible version used for the project is compatible with the panel firmware version.
    Event ID: 40000
    Tag read/write error. The panel is unable to read from or write to a configured PLC tag or variable.
    Check that the PLC data block or memory address referenced in the HMI project exists and is accessible. Verify data type consistency between the HMI tag configuration and the PLC variable. Confirm the PLC program is running correctly.
    Event ID: 70010
    System memory low warning. The available runtime memory on the panel is insufficient for the current project or operation.
    Reduce the number of active screens, alarms, or trend buffers in the WinCC flexible project. Check for memory leaks caused by scripts. Consider archiving or clearing alarm and data logs stored on the panel.
    Event ID: 110000
    Firmware update error. The panel firmware update process has failed or was interrupted.
    Restart the panel and attempt the firmware update again using ProSave or WinCC flexible. Ensure the correct firmware version for the MP 370 is used and that the power supply is stable during the update process.
    Event ID: 50000
    Recipe data error. A recipe transfer or read/write operation has encountered an inconsistency or failure.
    Verify the recipe configuration in WinCC flexible, ensuring that all recipe elements correspond to valid PLC tags. Check available storage space on the panel for recipe data files.

    Frequently Asked Questions

    What communication interfaces are available on the 6AV6446-3BA41-0BY4?

    The SIMATIC MP 370 (6AV6446-3BA41-0BY4) supports MPI, PROFIBUS DP, and Ethernet (TCP/IP) communication interfaces, as well as RS-422/485 serial communication, allowing connection to a wide range of Siemens S7 PLCs and third-party controllers.

    Which software is used to program and configure this HMI panel?

    The panel is configured using Siemens WinCC flexible engineering software. The runtime environment on the panel is WinCC flexible Runtime running on Windows CE.

    What is the display size and resolution of this panel?

    The 6AV6446-3BA41-0BY4 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA) and supports up to 64,000 colors.

    Is this panel compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the SIMATIC MP 370 is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP, and also supports S7 communication over Ethernet when equipped with the appropriate network configuration.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV6446-3BA41-0BY4 is rated IP65, providing complete protection against dust ingress and protection against low-pressure water jets, making it suitable for installation in industrial control cabinets and machine fronts.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector. Check that the voltage is within the specified tolerance. Inspect the internal fuse if accessible. Observe whether any LED indicators on the rear of the panel illuminate.

    Ensure the 24 V DC supply is stable and within tolerance. If the supply is correct and the display remains blank, the backlight inverter or the display unit itself may be faulty and require replacement. A qualified repair technician should inspect the internal power circuitry.

    Panel cannot establish communication with the PLC

    Verify the MPI or PROFIBUS address configured on the panel matches the project settings and the PLC configuration. Check the physical cable connections and ensure the correct cable type is used. Confirm that termination resistors are correctly placed on the PROFIBUS network.

    Correct any address mismatches in the WinCC flexible project and re-download the project to the panel. Replace faulty cables or connectors. Ensure only the two physical ends of the PROFIBUS segment have termination resistors enabled.

    Touch screen does not respond or responds inaccurately

    Check whether the touch screen responds at all by observing if any touch input registers. Determine if the issue is a complete failure or a calibration offset. Access the Windows CE control panel to check touch screen calibration settings.

    Recalibrate the touch screen through the Windows CE system settings or the SIMATIC HMI panel startup menu. If calibration does not resolve the issue, the touch screen overlay may be damaged or the touch controller hardware may require replacement.

    WinCC flexible project fails to transfer to the panel

    Confirm the panel is set to Transfer mode before initiating the download from the engineering PC. Check the transfer connection (Ethernet or serial cable). Verify that the WinCC flexible version on the PC is compatible with the panel firmware version.

    Switch the panel to Transfer mode via the Start Center menu. Use ProSave to update the panel firmware if a version mismatch is detected. Ensure the Ethernet or serial connection is stable and that any firewall software on the PC is not blocking the transfer.

    Panel reboots unexpectedly or freezes during operation

    Check the 24 V DC supply for voltage dips or instability, which can cause unexpected resets. Review the alarm and system event logs on the panel for any recorded fault events prior to the reboot. Assess whether the issue occurs on specific screens or operations, which may indicate a software fault.

    Stabilize the power supply and ensure adequate current capacity for the panel. If the issue is software-related, review and optimize the WinCC flexible project for excessive script execution or memory usage. Perform a firmware update if the panel firmware is outdated, using the ProSave utility.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart