• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-3AA40-3BY3 SIMATIC MP 370
    Awaiting product image

    Siemens 6AV6446-3AA40-3BY3 SIMATIC MP 370

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6446-3AA40-3BY3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-3AA40-3BY3 is a Multi Panel (MP 370) belonging to the SIMATIC HMI family, designed for demanding visualization and operator control tasks in industrial automation environments. This unit features a 15-inch TFT color display and is part of the MP 370 series, which represents a high-performance class of Siemens panel PCs and multi panels intended for complex process visualization. It operates within the SIMATIC HMI product range and is fully integrated into the Siemens TIA and STEP 7 engineering environments.

    The MP 370 Touch (6AV6446-3AA40-3BY3) is equipped with a resistive touchscreen interface on its 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and 64,000 colors. It supports multiple communication interfaces including MPI, PROFIBUS DP, and Ethernet (TCP/IP), enabling flexible integration into existing Siemens and third-party control architectures. The panel runs on Windows CE and is configurable using WinCC flexible engineering software. It provides onerous memory capacity for project data and supports USB and CF card interfaces for data transfer and project storage.

    The SIMATIC MP 370 is widely deployed in manufacturing, process automation, and machine building industries where large-format visualization and robust operator interaction are required. Its 15-inch display makes it suitable for control cabinets and operator stations in applications such as packaging machinery, automotive assembly lines, water treatment plants, and chemical processing facilities. The panel's compatibility with SIMATIC S7 PLCs and its support for PROFIBUS DP makes it a natural fit for Siemens-centric automation architectures.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Colors 64,000 colors
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 35 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (TCP/IP), USB
    Memory 12 MB project memory (Flash)
    Operating System Windows CE
    Engineering Software WinCC flexible
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Connection to PLC lost or communication timeout on configured connection.
    Check MPI/PROFIBUS/Ethernet cabling and termination resistors. Verify PLC is powered and running. Check connection parameters in WinCC flexible project.
    Event ID: 10001
    Connection to PLC established after a previous loss of communication.
    Informational event. No corrective action required. Monitor for recurring disconnections that may indicate network instability.
    Event ID: 20000
    Tag read/write error — the panel cannot read or write a configured tag from/to the PLC.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory area. Check PLC program for address conflicts.
    Event ID: 40000
    Project download error — project transfer to the panel failed or was interrupted.
    Check the transfer cable or Ethernet connection between the engineering PC and the panel. Ensure the panel is in Transfer mode and that WinCC flexible version is compatible.
    Event ID: 50000
    Insufficient memory — project memory on the panel is full or nearly exhausted.
    Reduce project size by optimizing graphics, removing unused tags, or compressing images. Consider archiving historical data to an external CF card.
    Event ID: 60000
    CF card not detected or read/write error on the CompactFlash card.
    Remove and reinsert the CF card. Check card for damage or corruption. Replace with a compatible CF card if errors persist.
    Event ID: 70000
    System runtime error — WinCC flexible Runtime has encountered an internal fault.
    Restart the panel. If the error recurs, reload the project via WinCC flexible. Check for firmware compatibility between the panel and the project version.

    Frequently Asked Questions

    What display size and resolution does the 6AV6446-3AA40-3BY3 have?

    The 6AV6446-3AA40-3BY3 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA) and supports 64,000 colors.

    Which communication interfaces are available on this MP 370 panel?

    The panel supports MPI, PROFIBUS DP, and Ethernet (TCP/IP) for PLC connectivity, as well as USB ports for peripherals and data transfer. A CompactFlash card slot is also provided for storage.

    Which engineering software is used to configure the SIMATIC MP 370?

    The MP 370 is configured using Siemens WinCC flexible engineering software. It is not compatible with the newer TIA Portal WinCC Advanced without a migration step.

    Is the 6AV6446-3AA40-3BY3 compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the MP 370 is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP, and can also communicate with S7 controllers over Ethernet using the appropriate driver.

    What is the front panel protection rating of this unit?

    The front panel of the MP 370 carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check that the voltage is within the specified range and that polarity is correct. Inspect the internal fuse if accessible.

    Correct any supply voltage issues. If the supply is confirmed good and the display remains blank, the backlight inverter or the display itself may have failed and the unit should be sent for repair or the backlight replaced.

    Touchscreen does not respond or responds inaccurately

    Attempt to recalibrate the touchscreen via the Windows CE Control Panel or the SIMATIC HMI startup menu. Check for physical damage, scratches, or contamination on the touch surface.

    Perform a touchscreen recalibration. Clean the screen surface with a soft, dry cloth. If calibration does not resolve the issue, the resistive touch overlay may be worn or damaged and requires replacement.

    Panel fails to establish communication with the PLC

    Verify the MPI or PROFIBUS address configured in the WinCC flexible project matches the address set on the panel and the PLC. Check cable integrity and bus termination at both ends of the network.

    Correct address mismatches in the project configuration and reload the project to the panel. Replace damaged cables and ensure proper bus termination resistors are installed at the physical ends of the PROFIBUS or MPI segment.

    Project transfer from engineering PC to panel fails

    Confirm the panel is set to Transfer mode (accessible via the Start Center on the panel). Check that the IP address or MPI address used in WinCC flexible matches the panel settings. Verify the Ethernet or MPI cable is functional.

    Set the panel to Transfer mode before initiating the download. Correct any address mismatches. Try a different cable or transfer method (e.g., switch from MPI to Ethernet transfer). Ensure the WinCC flexible version matches the panel firmware version.

    Panel displays a white or distorted screen after startup

    This may indicate a corrupted project file or a firmware issue. Attempt to restart the panel and observe whether the issue occurs before or after the WinCC flexible Runtime loads.

    Reload the project from the engineering PC using WinCC flexible. If the issue persists before Runtime loads, perform a panel reset to factory defaults via the SIMATIC HMI startup menu and re-transfer the project. A firmware update may also be required.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart