• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-1BA40-0BA4 SIMATIC MP 370
    Awaiting product image

    Siemens 6AV6446-1BA40-0BA4 SIMATIC MP 370

    € 2.995,00

    Reset
    Clear
    SKU: 6AV6446-1BA40-0BA4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-1BA40-0BA4 is a Multi Panel (MP 370) belonging to the SIMATIC HMI Multi Panel series, manufactured by Siemens. It is a high-performance operator panel designed for demanding visualization and control tasks in industrial automation environments. The MP 370 features a 12-inch TFT display and runs on the Windows CE operating system, providing a robust platform for human-machine interface applications.

    The 6AV6446-1BA40-0BA4 variant is equipped with a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It includes multiple communication interfaces such as MPI, PROFIBUS DP, and Ethernet (TCP/IP), enabling flexible integration into various network architectures. The panel features 12 MB of user memory for project data, a CompactFlash card slot for data storage and project transfer, and a USB interface for peripheral connectivity. It operates on 24 V DC supply voltage and is built to meet the rigorous demands of industrial environments.

    The SIMATIC MP 370 is widely used in manufacturing, process automation, and machine building industries where complex visualization tasks and high graphical performance are required. It is suitable for applications in automotive production lines, chemical processing plants, food and beverage manufacturing, and packaging machinery. Its compatibility with Siemens SIMATIC S7 PLCs and WinCC flexible configuration software makes it a natural choice for Siemens-based automation systems requiring a capable and reliable operator interface.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 256 colors
    Touch Technology Resistive touch screen
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 40 W
    User Memory 12 MB
    Operating System Windows CE
    Communication Interface MPI, PROFIBUS DP, Ethernet (TCP/IP), USB
    Storage Slot CompactFlash card slot
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been interrupted.
    Check MPI/PROFIBUS or Ethernet cable connections and termination resistors. Verify PLC address settings and communication parameters in WinCC flexible project match the hardware configuration.
    Event ID: 10001
    Connection to PLC timed out. The HMI panel did not receive a response from the controller within the expected time frame.
    Check network cabling and connector integrity. Verify PLC is in RUN mode and communication parameters (baud rate, station address) are correctly configured on both devices.
    Event ID: 20000
    Tag read error. The HMI panel was unable to read the value of a configured tag from the PLC.
    Verify the tag address in the WinCC flexible project matches the actual data block or memory area in the PLC program. Check PLC program is running and the address exists.
    Event ID: 40000
    Project download error. Transfer of the HMI project from the configuration PC to the panel failed.
    Check USB or Ethernet transfer cable connection. Ensure the panel is in Transfer mode and the correct transfer channel is selected in WinCC flexible Transfer settings.
    Event ID: 50000
    System memory low. Available memory on the HMI panel is insufficient to load or run the current project.
    Reduce project size by optimizing graphics and scripts. Delete unnecessary data from the CompactFlash card. Consider archiving historical data to free up memory.
    Event ID: 60000
    CompactFlash card error. The panel cannot read from or write to the inserted CompactFlash card.
    Remove and reinsert the CompactFlash card. Check the card for damage or corruption. Replace the CompactFlash card if the error persists. Ensure the card is formatted correctly (FAT16/FAT32).
    Event ID: 70000
    Backup battery low or missing. The internal backup battery voltage has dropped below the minimum threshold.
    Replace the internal backup battery with the correct Siemens replacement battery. Refer to the MP 370 operating instructions for battery replacement procedure to avoid data loss.

    Frequently Asked Questions

    What configuration software is used to program the SIMATIC MP 370 (6AV6446-1BA40-0BA4)?

    The MP 370 is configured using Siemens WinCC flexible software. The project is then transferred to the panel via USB, Ethernet, or MPI/PROFIBUS connection.

    Which communication interfaces are available on the 6AV6446-1BA40-0BA4?

    This panel provides MPI, PROFIBUS DP, and Ethernet (TCP/IP) interfaces for PLC communication, as well as USB ports for peripheral devices and project transfer. A serial RS-232/RS-422/RS-485 interface is also available.

    Is the MP 370 compatible with Siemens S7-300 and S7-400 PLCs?

    Yes, the SIMATIC MP 370 is fully compatible with Siemens S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with S7-200 PLCs and third-party controllers via the available serial interfaces.

    What is the display type and resolution of the 6AV6446-1BA40-0BA4?

    The panel features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and supports resistive touch screen input.

    What is the supply voltage requirement for the MP 370?

    The SIMATIC MP 370 requires a 24 V DC supply voltage. Ensure the power supply can deliver sufficient current to meet the panel's maximum power consumption of 40 W.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC supply voltage is present at the power connector. Measure voltage at the panel terminals to confirm adequate supply. Inspect the internal fuse if accessible.

    Verify and correct the power supply voltage and connections. If supply voltage is confirmed correct and the display remains blank, the internal power supply board or backlight inverter may require replacement or repair.

    Touch screen does not respond or responds inaccurately

    Attempt to recalibrate the touch screen via the panel's Start Center or Control Panel settings. Check for physical damage or contamination on the touch surface.

    Perform a touch screen calibration through the Windows CE Control Panel. Clean the touch surface with a soft, dry cloth. If calibration fails or the touch screen remains unresponsive, the touch screen overlay or controller board may need replacement.

    HMI panel cannot establish communication with the PLC

    Verify cable connections on MPI, PROFIBUS, or Ethernet interface. Check that the station address and baud rate configured in the WinCC flexible project match the PLC and network settings.

    Correct any mismatched communication parameters in the WinCC flexible project and re-download to the panel. Replace the communication cable if damaged. Ensure PROFIBUS termination resistors are correctly placed at both ends of the bus.

    Project transfer from PC to panel fails

    Confirm the panel is set to Transfer mode via the Start Center. Check the transfer channel settings in WinCC flexible match the physical connection being used (USB, Ethernet, or MPI).

    Switch the panel to Transfer mode and retry the download. If using Ethernet, verify IP address settings on both PC and panel. Try an alternative transfer cable or interface if the issue persists.

    Panel reboots unexpectedly or freezes during operation

    Check the supply voltage for fluctuations or drops below 24 V DC. Review the project for memory-intensive scripts or excessive tag polling rates that may overload the panel CPU.

    Stabilize the power supply and ensure adequate current capacity. Optimize the WinCC flexible project by reducing update cycles and script complexity. If reboots continue, check for hardware faults and consider a firmware update or panel repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart