• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-1AA40-0BA5 SIMATIC MP 370
    Awaiting product image

    Siemens 6AV6446-1AA40-0BA5 SIMATIC MP 370

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6446-1AA40-0BA5 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-1AA40-0BA5 is a Multi Panel (MP 370) belonging to the SIMATIC HMI family, designed for demanding visualization and operator control tasks in industrial automation environments. This panel features a 12-inch TFT display and is part of the SIMATIC MP 370 series, which provides high-performance human-machine interface functionality for process and machine visualization. It is manufactured by Siemens and operates within the broader SIMATIC HMI product line.

    The MP 370 panel is equipped with a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), supporting 256 colors. It features a touch screen interface and can be configured with an MPI/PROFIBUS DP interface for direct connection to SIMATIC S7 PLCs, as well as Ethernet connectivity for network integration. The panel runs on WinCC flexible runtime software, supports multiple communication drivers, and provides a robust industrial-grade enclosure rated to IP65 on the front face. Internal memory supports project storage and runtime data logging.

    The SIMATIC MP 370 is widely used in machine building, automotive manufacturing, food and beverage processing, and chemical plant automation. Its large display area and touch operation make it suitable for complex process visualization, recipe management, alarm logging, and trend display applications. The panel is particularly well suited for installations requiring a robust, panel-mount HMI with direct PLC connectivity and network communication capabilities.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color
    Display Colors 256 colors
    Touch Technology Resistive touch screen
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 30 W
    Communication Interface MPI/PROFIBUS DP, Ethernet (RJ45)
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Series/Product Family SIMATIC MP 370
    Certifications CE, UL, cUL

    Common Error Codes & System Events

    Event ID: 1000001
    System startup completed successfully. The HMI runtime has initialized without errors.
    No action required. This is an informational event confirming normal startup.
    Event ID: 1000002
    Connection to PLC lost. The HMI panel cannot establish or maintain communication with the configured PLC.
    Check MPI/PROFIBUS DP or Ethernet cable connections. Verify PLC address settings and communication parameters in WinCC flexible. Ensure the PLC is powered and in RUN mode.
    Event ID: 1000003
    Tag read error. A configured tag could not be read from the PLC within the timeout period.
    Verify the tag address exists in the PLC program. Check communication connection and PLC data block configuration. Reload the project if necessary.
    Event ID: 1000004
    Project download error. A project transfer to the panel was interrupted or failed.
    Check the transfer cable or network connection. Ensure WinCC flexible is configured with the correct panel type and transfer settings. Retry the download.
    Event ID: 1000005
    Insufficient memory. The panel does not have enough free memory to load or run the current project.
    Delete unused projects or data logs from the panel memory. Optimize the project size in WinCC flexible and reduce the number of stored alarms or recipe records.
    Event ID: 1000006
    Alarm buffer overflow. The alarm log has reached its maximum capacity.
    Acknowledge and clear pending alarms. Archive or export the alarm log and clear the buffer via the panel's system settings.
    Event ID: 1000007
    Screen saver activated. The display has entered screen saver mode due to inactivity.
    Touch the screen or press any key to deactivate the screen saver. Adjust the screen saver timeout in the panel's system settings if required.
    Event ID: 1000008
    Backup battery low. The internal backup battery voltage is below the minimum threshold.
    Replace the internal backup battery as soon as possible to prevent loss of time, date, and retained data. Use the Siemens-specified replacement battery type.

    Frequently Asked Questions

    What PLC systems is the SIMATIC MP 370 compatible with?

    The MP 370 is primarily designed for use with Siemens SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. It also supports communication with S5 PLCs and third-party controllers through additional communication drivers available in WinCC flexible.

    What software is used to configure the MP 370 panel?

    The MP 370 is configured using Siemens WinCC flexible engineering software. Projects are created on a PC and transferred to the panel via MPI, PROFIBUS DP, or Ethernet.

    What is the supply voltage for the 6AV6446-1AA40-0BA5?

    The panel operates on 24 V DC supply voltage, which is the standard supply for SIMATIC HMI panels in this series.

    What is the front panel protection rating of the MP 370?

    The front face of the MP 370 panel is rated IP65, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel-mount installations.

    Can the MP 370 be used for data logging and recipe management?

    Yes, the MP 370 supports data logging, recipe management, alarm logging, and trend display functions through the WinCC flexible runtime environment.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC supply voltage is present at the power connector. Verify polarity and measure voltage with a multimeter. Check internal fuse if accessible.

    Ensure the 24 V DC supply is within tolerance. Replace the supply fuse if blown. If the supply is correct and the display remains blank, the internal power supply or backlight inverter may require replacement.

    Touch screen does not respond or responds inaccurately

    Determine whether the issue is a complete lack of response or positional inaccuracy. Check for physical damage or contamination on the touch surface.

    Recalibrate the touch screen via the panel's Start Center or system settings. Clean the touch surface with a soft, dry cloth. If calibration does not resolve the issue, the touch screen overlay may need replacement.

    Communication loss with PLC (connection drops intermittently)

    Check MPI or PROFIBUS DP cable connections and termination resistors at both ends of the bus. Verify bus address settings and baud rate configuration on both the panel and PLC.

    Replace or reseat communication cables. Ensure correct bus termination is applied. Verify that the panel's MPI/PROFIBUS address does not conflict with other devices on the network. Update communication parameters in WinCC flexible if necessary.

    Project transfer fails during download from PC

    Verify the transfer cable type and connection. Check that the panel is in Transfer mode via the Start Center. Confirm that WinCC flexible is configured for the correct panel type and interface.

    Switch the panel to Transfer mode manually from the Start Center. Use the correct MPI or Ethernet transfer settings in WinCC flexible. Try a different cable or network path. Ensure the PC firewall is not blocking the transfer.

    Panel displays 'Offline' or cannot find configured tags

    The runtime project may not be loaded, or the PLC connection configuration may be incorrect. Check the connection settings in WinCC flexible for correct PLC address and communication interface.

    Reload the project to the panel. Verify PLC address, slot number, and rack number in the WinCC flexible connection settings. Confirm the PLC is powered and in RUN mode with the correct program loaded.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart