Siemens 6AV6381-2CB07-5AX0 WinCC flexible 2007
€ 1.667,00
The Siemens 6AV6381-2CB07-5AX0 is a software license for WinCC flexible 2007 Compact, part of Siemens' WinCC flexible engineering software family. This product provides the engineering environment used to configure and program Siemens HMI panels, including the OP, TP, MP, and Mobile Panel series. It is designed for use on a standard engineering PC running a compatible Windows operating system.
WinCC flexible 2007 Compact supports configuration of smaller HMI devices and offers a project-oriented workflow with a structured tag management system, alarm logging, recipe management, and screen editor. The software communicates with Siemens SIMATIC S7 PLCs via standard interfaces and supports integration within the SIMATIC automation environment. It includes a runtime simulation function that allows testing of HMI projects directly on the engineering PC without requiring connected hardware.
This software is used across a wide range of industrial automation applications where Siemens HMI panels are deployed, including machine tool control, packaging machinery, conveyor systems, and process automation. It is particularly suited for small to mid-scale HMI projects where a compact engineering tool is sufficient. System integrators, OEMs, and maintenance engineers use this software to develop, modify, and maintain HMI visualization projects.
Technical Specifications
| Software Version | WinCC flexible 2007 Compact |
|---|---|
| License Type | Single-user license |
| Host Operating System | Windows XP / Windows Vista (32-bit) |
| Series/Product Family | WinCC flexible |
| Supported HMI Devices | Micro Panels, OP 73, TP 177, OP 177, and compatible compact HMI panels |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Communication Interface | MPI, PROFIBUS DP, Ethernet (via supported HMI hardware) |
| Tag Limit | Up to 128 process tags (Compact edition) |
| Runtime Simulation | Included |
| Alarm Management | Supported |
| Recipe Management | Supported |
| Certifications | CE |
Common Error Codes and Software Events
- License Error 1
- No valid license found for WinCC flexible 2007 Compact on the engineering PC
Verify that the USB license dongle or software license is correctly installed. Use Siemens Automation License Manager (ALM) to check license status and transfer if necessary. - License Error 2
- License has expired or is invalid
Check the license validity period in the Automation License Manager. Renew or reactivate the license through Siemens licensing portal. - Compiler Error
- Project compilation fails due to inconsistent tag references or missing device configuration
Review the project for unresolved tag references, missing PLC connections, or unsupported device types. Correct all reported inconsistencies before recompiling. - Transfer Error
- Project transfer to HMI panel fails
Check the communication cable connection and interface settings. Verify that the HMI panel is in transfer mode and that the correct communication channel is selected in the project settings. - Simulation Runtime Error
- Runtime simulation crashes or fails to start on the engineering PC
Ensure the PC meets minimum system requirements. Check that no conflicting software or firewall rules are blocking the simulation runtime process. - Device Mismatch Warning
- Configured HMI device type does not match the connected physical panel
Open the project properties and verify that the selected HMI device type matches the physical panel model and firmware version. Update the device configuration if necessary. - Database Consistency Error
- Project database is corrupted or inconsistent, preventing the project from opening
Use the WinCC flexible project repair function if available. Restore from a recent backup or reimport project components to rebuild the database.
Frequently Asked Questions
What HMI panels are supported by WinCC flexible 2007 Compact?
WinCC flexible 2007 Compact supports Siemens Micro Panels, OP 73, TP 177, OP 177, and other compact HMI devices within the SIMATIC HMI family. It does not support the full range of Multi Panels or PC-based runtime systems, which require the Standard or Advanced editions.
Is a hardware dongle required to run this software?
Siemens WinCC flexible 2007 licenses are typically managed via the Siemens Automation License Manager (ALM). Depending on the license type, a USB dongle or a software-based license key may be required.
Can WinCC flexible 2007 projects be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. Some manual rework may be required depending on the complexity of the project and the target HMI device.
What is the maximum number of process tags supported in the Compact edition?
The Compact edition of WinCC flexible 2007 supports up to 128 process tags, which is suitable for smaller HMI applications with limited I/O requirements.
Which Windows operating systems are compatible with WinCC flexible 2007?
WinCC flexible 2007 is compatible with Windows XP Professional and Windows Vista (32-bit editions). It is not officially supported on Windows 7 or later without additional compatibility measures.
Troubleshooting
Software fails to install on the engineering PC
Check the Windows version and ensure it meets the minimum requirements. Review the installation log for specific error messages related to missing prerequisites or permission issues.
Install all required Microsoft prerequisites such as .NET Framework and MSXML. Run the installer with administrator privileges. Ensure no previous conflicting versions of WinCC flexible are partially installed.
Automation License Manager does not detect the license
Open the Automation License Manager and check whether the license appears under the correct drive or dongle. Verify that the USB dongle is recognized by the operating system.
Reinstall the Automation License Manager. Try a different USB port for the dongle. If using a software license, perform a license repair or transfer using the ALM tool.
Project cannot be transferred to the HMI panel
Verify the communication settings in the project match the physical connection type (USB, Ethernet, or serial). Confirm the HMI panel is in transfer mode by checking its startup screen.
Correct the transfer channel settings in WinCC flexible. Replace the communication cable if damaged. Ensure the HMI panel firmware version is compatible with the project configuration.
Simulation does not reflect the latest project changes
Check whether the project was saved and compiled successfully before starting the simulation. Look for compilation warnings or errors in the output window.
Save and recompile the project fully before launching the simulation. Clear any cached simulation data and restart the simulation runtime.
Screen objects or tags appear missing after opening an existing project
The project may have been created with a different version of WinCC flexible or with a device type that is not supported by the Compact edition.
Verify the project was originally created with a compatible edition and device type. If upgrading from an older version, run the project migration wizard and review all reported conversion issues.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page