
Siemens 6AV6381-2BU07-5AV0 WinCC flexible 2007
€ 2.495,00
The Siemens 6AV6381-2BU07-5AV0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing HMI (Human-Machine Interface) applications used in conjunction with Siemens SIMATIC HMI panels and PC-based systems. It belongs to the broader SIMATIC HMI software portfolio and is designed for use on standard engineering PCs running compatible Windows operating systems.
WinCC flexible 2007 offers a scalable engineering environment supporting the full range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based runtime systems. The software provides tag-based licensing, project migration tools, and a library of pre-built faceplates and objects to accelerate HMI development. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and integrates with SIMATIC S7-200, S7-300, S7-400, and WinAC controllers. The engineering environment includes alarm management, recipe management, trend displays, and multi-language project support.
WinCC flexible 2007 is used across a wide range of industrial automation applications including manufacturing, process control, packaging machinery, and material handling systems. It is particularly suited for machine builders and system integrators who require a standardized HMI engineering platform compatible with the SIMATIC controller ecosystem. The software enables consistent visualization across distributed production lines and standalone machine installations.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| Software Type | HMI Engineering Software |
| License Type | Single-user license |
| Compatible HMI Devices | SIMATIC HMI Micro Panels, OP/TP Panels, Multi Panels, MP Series |
| Compatible Controllers | SIMATIC S7-200, S7-300, S7-400, WinAC |
| Communication Interfaces | PROFIBUS, PROFINET, MPI, Industrial Ethernet |
| Operating System | Windows XP, Windows 2000 (Professional) |
| Project Languages | Up to 32 languages per project |
| Alarm Management | Included |
| Recipe Management | Included |
| Trend Display | Included |
| Series/Product Family | SIMATIC WinCC flexible |
Common Error Codes & System Events
- Event ID: 1000001
- License not found or invalid license key detected during software startup
Verify the license dongle or software license is correctly installed. Use Siemens Automation License Manager (ALM) to check license status and transfer or repair the license as needed. - Event ID: 1000002
- Project compilation error due to incompatible HMI device type selected
Check that the target HMI device configured in the project matches the actual hardware. Update the device type in project properties and recompile. - Event ID: 1000003
- Communication connection to HMI panel failed during download
Verify the communication cable and interface settings. Confirm the correct COM port or Ethernet IP address is configured in the transfer settings. Check that the HMI panel is in transfer mode. - Event ID: 1000004
- Tag limit exceeded for current license tier
Review the number of configured tags in the project. Upgrade the WinCC flexible license to a higher tag count tier or reduce the number of tags used in the project. - Event ID: 1000005
- Runtime error on PC station due to missing or corrupt runtime installation
Reinstall the WinCC flexible Runtime component using the original installation media. Ensure all prerequisites and service packs are applied. - Event ID: 1000006
- Project migration error when opening a project created in an older WinCC flexible version
Use the integrated migration wizard to convert the project. Back up the original project before migration. Check Siemens release notes for known migration limitations between versions. - Event ID: 1000007
- Inconsistent project data detected, possibly due to interrupted save or file corruption
Restore the project from the most recent backup. If no backup is available, use the project consistency check tool within WinCC flexible to identify and resolve inconsistencies.
Frequently Asked Questions
What HMI devices are supported by WinCC flexible 2007?
WinCC flexible 2007 supports the full range of SIMATIC HMI devices including Micro Panels, OP/TP operator panels, Multi Panels, and MP Series panels. It also supports PC-based WinCC flexible Runtime installations.
Which SIMATIC controllers can be integrated with WinCC flexible 2007?
The software supports communication with SIMATIC S7-200, S7-300, S7-400, and WinAC controllers via MPI, PROFIBUS, and Industrial Ethernet/PROFINET interfaces.
What operating systems are compatible with WinCC flexible 2007?
WinCC flexible 2007 is compatible with Windows XP Professional and Windows 2000 Professional. It is not natively supported on Windows 7 or later without compatibility measures.
Is a hardware dongle required to run WinCC flexible 2007?
License management is handled through the Siemens Automation License Manager (ALM). Depending on the license variant, a USB hardware dongle or a software-based license may be required.
Can projects created in WinCC flexible 2007 be migrated to TIA Portal?
Yes, Siemens provides migration tools within TIA Portal to import WinCC flexible projects, though some manual rework may be required depending on the complexity of the project and the target TIA Portal version.
Troubleshooting
Software fails to start and displays a license error
Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC flexible 2007 license is present and not expired or damaged.
Transfer a valid license to the engineering PC using ALM. If the license is shown as defective, contact Siemens support for license recovery. Ensure the USB dongle is connected if a hardware-based license is used.
Project download to HMI panel fails with a connection error
Check the physical connection between the PC and the HMI panel. Verify the transfer settings including interface type, COM port or IP address, and baud rate. Confirm the panel is set to transfer mode.
Correct the interface settings in the WinCC flexible transfer dialog. Replace the communication cable if faulty. For Ethernet transfers, ensure both devices are on the same subnet and no firewall is blocking the connection.
Compiled project reports tag count exceeded warning
Review the total number of external tags configured in the project. Compare against the tag limit of the installed license tier.
Reduce the number of external tags by consolidating or removing unused tags, or upgrade the WinCC flexible license to a higher tag count variant using the Automation License Manager.
Older project cannot be opened and displays a migration error
Determine the original version of WinCC flexible used to create the project. Check if the version is supported for direct migration to WinCC flexible 2007.
Use the WinCC flexible migration wizard to convert the project step by step. Always back up the original project files before attempting migration. Refer to Siemens release notes for version-specific migration paths.
Runtime PC station shows blank screen or HMI application does not start
Check Windows Event Viewer for runtime errors. Verify that the WinCC flexible Runtime component is installed and that the correct project file is configured for autostart.
Reinstall the WinCC flexible Runtime using the original installation media. Verify the startup project path in the runtime settings. Ensure the PC meets the minimum hardware requirements for the runtime application.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page


