• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BT08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BT08-0AX0 WinCC flexible 2008

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6381-2BT08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BT08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens operator panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is designed for use with the full range of Siemens HMI hardware platforms.

    WinCC flexible 2008 offers a comprehensive set of engineering tools for creating HMI visualizations, including drag-and-drop screen design, tag management, alarm handling, recipe management, and trend displays. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It includes a library of pre-built faceplates and symbols, supports multi-language project management, and provides simulation capabilities for offline testing of HMI applications without physical hardware.

    WinCC flexible 2008 is widely used in manufacturing automation, process control, and machine building industries where Siemens HMI panels such as the TP, OP, MP, and Mobile Panel series are deployed. It is suitable for applications ranging from small standalone machines to distributed production lines requiring centralized visualization. The software is particularly common in automotive, food and beverage, pharmaceutical, and general industrial manufacturing environments.

    Technical Specifications

    Software Version WinCC flexible 2008
    Software Type Engineering Software / HMI Configuration Tool
    Compatible HMI Hardware SIMATIC HMI TP, OP, MP, Mobile Panel series
    Compatible PLCs SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7
    License Type Single-user license
    Series/Product Family SIMATIC WinCC flexible
    Language Support Multi-language project management
    Simulation Integrated offline simulation supported
    Certifications CE

    Common Error Codes and System Events

    Event ID: 1000001
    Communication error between engineering station and HMI device during project download
    Check the communication cable and interface settings. Verify the correct communication driver is selected and the PLC/HMI address configuration matches the physical setup.
    Event ID: 1000002
    License not found or license key invalid during software startup
    Verify the license dongle is connected or the software license is correctly installed using the Siemens Automation License Manager (ALM). Re-install the license if necessary.
    Event ID: 1000010
    Project compilation error due to inconsistent tag configuration
    Open the project in WinCC flexible, navigate to the tag editor, and resolve any highlighted inconsistencies such as duplicate tag names or invalid data types.
    Event ID: 1000020
    Runtime transfer failed – target HMI device not reachable
    Check network or serial connection to the HMI panel. Confirm the HMI device is in transfer mode and the correct transfer channel is configured in the project settings.
    Event ID: 1000030
    Insufficient memory on target HMI device for project download
    Reduce the project size by removing unused screens, tags, or graphics. Check the memory requirements against the target device specifications.
    Event ID: 1000040
    Version incompatibility between WinCC flexible engineering software and target HMI device firmware
    Update the HMI device firmware to a version compatible with WinCC flexible 2008, or use the migration wizard to adapt the project to the correct device version.
    Event ID: 1000050
    Alarm log or data log configuration error in project
    Review the alarm and data log settings in the project. Ensure storage locations are correctly defined and the target device supports the configured log size.

    Frequently Asked Questions

    Which Siemens PLC families are compatible with WinCC flexible 2008?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet. It also supports third-party controllers via OPC and other standard drivers.

    Which operating systems are supported by WinCC flexible 2008?

    WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7. It is not natively supported on Windows 10 or later without compatibility measures.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible projects to be imported and converted for use with WinCC in TIA Portal, though some manual rework may be required.

    Does WinCC flexible 2008 support offline simulation without physical HMI hardware?

    Yes, WinCC flexible 2008 includes an integrated simulator that allows HMI projects to be tested on a PC without requiring a physical HMI panel to be connected.

    What is the difference between WinCC flexible Runtime and the engineering software?

    The engineering software (6AV6381-2BT08-0AX0) is used to create and configure HMI projects on a PC. The Runtime software is a separate license required to run the HMI application on a PC-based system, while dedicated HMI panels include their own runtime environment.

    Troubleshooting

    Software fails to start and displays a license error message

    Check whether the Siemens Automation License Manager (ALM) detects a valid license. Verify if a hardware dongle is required and whether it is connected to the PC.

    Install or re-activate the license using the Siemens Automation License Manager. If a USB dongle is used, ensure it is firmly connected and recognized by the operating system before launching the software.

    Project download to HMI panel fails with a communication error

    Verify the physical connection between the PC and the HMI panel (USB, Ethernet, or MPI/PROFIBUS cable). Check that the HMI panel is set to transfer mode and the correct communication channel is selected in the project transfer settings.

    Correct the communication settings in WinCC flexible to match the physical interface. Restart the HMI panel in transfer mode and retry the download. Replace the communication cable if a hardware fault is suspected.

    Compiled project reports tag or screen errors and will not compile successfully

    Open the project validation report in WinCC flexible to identify the specific errors. Common causes include duplicate tag names, references to deleted objects, or data type mismatches between PLC and HMI tags.

    Resolve each reported error in the tag editor or screen editor. Ensure all PLC tags referenced in the HMI project match the actual PLC data block structure, then recompile the project.

    WinCC flexible 2008 installation fails or crashes on Windows 7

    Check the Windows Event Viewer for installation error codes. Verify that all prerequisites such as .NET Framework and SIMATIC automation software components are installed and that the user account has administrator privileges.

    Run the installer as administrator and ensure all required Microsoft redistributable packages are installed. Disable antivirus software temporarily during installation and follow the Siemens installation guide for WinCC flexible 2008.

    HMI runtime on panel shows communication fault alarms after project transfer

    Check the PLC connection settings in the WinCC flexible project, including the PLC IP address or MPI address, rack, and slot number. Verify the PLC is powered and running, and that the network cable or bus connection is intact.

    Correct the PLC connection parameters in the WinCC flexible project and re-transfer to the HMI panel. Confirm the PLC program is in RUN mode and that no firewall or network switch is blocking communication on the configured port.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart