Siemens 6AV6381-2BT08-0AH0 WinCC flexible 2008
The Siemens 6AV6381-2BT08-0AH0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for a wide range of operator panels.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It provides a library of pre-built faceplates and graphic objects, multi-language project support, and integration with the broader Siemens TIA (Totally Integrated Automation) ecosystem. The 2008 version introduced enhanced performance, improved usability, and extended panel compatibility.
WinCC flexible 2008 is widely used in manufacturing, process automation, water treatment, food and beverage, and machine building industries. It is suitable for configuring operator panels ranging from Micro Panels and Mobile Panels to Multi Panels and PC-based runtime systems. The software is particularly valued in applications requiring structured HMI project management, centralized engineering, and seamless integration with Siemens SIMATIC controllers.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Full software license |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Scripting Support | VBScript |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Project Languages | Multi-language support |
| Series/Product Family | SIMATIC WinCC flexible |
| Certifications | CE |
| Integration | TIA Portal compatible (migration support) |
| Panel Compatibility | Micro Panels, Mobile Panels, Multi Panels, PC Runtime |
| Alarm Logging | Supported |
| Recipe Management | Supported |
| Trend Display | Supported |
Common Error Codes & System Events
- Event ID: 1000000
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly.
Check that the correct runtime license is installed and that the project file is not corrupted. Reinstall the runtime if necessary. - Event ID: 1000003
- Communication error — No connection established to the configured PLC.
Verify PLC address settings, check physical communication cable or network connection, and confirm PLC is powered and in RUN mode. - Event ID: 1000010
- Tag read/write error — A configured tag could not be read from or written to the controller.
Check tag address configuration in the project, verify PLC data block or memory area exists, and confirm communication is active. - Event ID: 1000020
- License not found — No valid WinCC flexible license detected on the system.
Use Siemens Automation License Manager (ALM) to verify and transfer the correct license to the engineering PC or runtime device. - Event ID: 1000050
- Project load error — The HMI project could not be loaded by the runtime.
Recompile and retransfer the project from the engineering station. Check for project version compatibility between engineering software and runtime. - Event ID: 1000100
- Alarm buffer overflow — The alarm buffer has reached its maximum capacity.
Acknowledge and clear pending alarms. Review alarm configuration to reduce unnecessary alarm generation or increase buffer size in project settings. - Event ID: 1000200
- Recipe data error — Recipe record could not be read or written correctly.
Check recipe configuration, verify that the associated data records are not corrupted, and confirm sufficient storage space is available on the target device.
Frequently Asked Questions
Which SIMATIC panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports a wide range of Siemens SIMATIC HMI panels including Micro Panels (KTP series), Mobile Panels, Comfort Panels, Multi Panels, and PC-based runtime systems running Windows.
Is WinCC flexible 2008 compatible with the TIA Portal?
WinCC flexible 2008 projects can be migrated to the TIA Portal using Siemens' migration tools, but the software itself is a standalone engineering environment separate from TIA Portal.
What operating systems are supported for the engineering station?
WinCC flexible 2008 supports Windows XP, Windows Vista, and Windows 7 (32-bit editions). It is not natively supported on Windows 10 or later without compatibility measures.
Does WinCC flexible 2008 require a separate runtime license?
Yes, a separate WinCC flexible Runtime license is required to run HMI projects on a PC-based system. Panel-based devices include the runtime license with the hardware.
What communication protocols does WinCC flexible 2008 support?
The software supports MPI, PROFIBUS DP, and Industrial Ethernet (TCP/IP) for communication with SIMATIC S7 PLCs, as well as OPC DA for third-party controller integration.
Troubleshooting
WinCC flexible Runtime does not start after project transfer
Check the Automation License Manager (ALM) to confirm a valid runtime license is present. Review Windows Event Viewer for startup error codes.
Transfer a valid WinCC flexible Runtime license using ALM. If the license is present, recompile the project in the engineering software and retransfer to the target device.
No communication between HMI project and SIMATIC PLC
Verify the PLC address and communication driver settings in the project. Check physical connections (MPI cable, PROFIBUS cable, or Ethernet cable) and confirm the PLC is powered and in RUN mode.
Correct the PLC address in the WinCC flexible connection settings, replace or reseat the communication cable, and ensure the correct communication driver is installed on the engineering PC or panel.
Project compilation fails with errors in WinCC flexible 2008
Review the compiler output log for specific error messages. Common causes include missing tag references, invalid script syntax, or incompatible panel type selection.
Correct all flagged errors in the project editor — check tag names, VBScript syntax, and ensure the selected target panel type matches the physical device. Recompile after each correction.
Alarms are not displayed correctly at runtime
Check alarm configuration in the engineering project, including trigger tags, alarm classes, and display settings. Verify that the PLC tags linked to alarm triggers are communicating correctly.
Recheck alarm tag addresses and ensure the alarm view object on the HMI screen is correctly configured. Retransfer the project after making corrections.
WinCC flexible 2008 installation fails on the engineering PC
Check Windows compatibility (32-bit OS required for full functionality), available disk space, and whether a previous version of WinCC flexible is partially installed.
Uninstall any previous WinCC flexible versions cleanly using the Siemens uninstall tool, ensure at least 4 GB of free disk space, and run the installer with administrator privileges on a supported 32-bit Windows OS.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page