• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BL08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BL08-0AX0 WinCC flexible 2008

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6381-2BL08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BL08-0AX0 is a software license for WinCC flexible 2008, Siemens' engineering software platform for configuring and commissioning HMI (Human-Machine Interface) panels and visualization systems. It belongs to the WinCC flexible product family, which is part of the SIMATIC HMI portfolio. This software package provides the engineering environment for creating HMI projects compatible with a wide range of Siemens operator panels, including the TP, OP, MP, and Mobile Panel series.

    WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS, and Ethernet interfaces. It includes a simulation function that allows project testing without physical hardware, and supports multi-language project configuration for international deployments. The 2008 version introduced enhanced usability features and expanded panel compatibility compared to earlier releases.

    WinCC flexible 2008 is used across a broad range of industrial sectors including automotive manufacturing, food and beverage processing, pharmaceutical production, and machine building. It is the standard engineering tool for configuring Siemens SIMATIC HMI panels deployed on production lines, packaging machines, press systems, and process control applications. Its tight integration with the SIMATIC automation environment makes it a practical choice for facilities already using Siemens PLCs and drive systems.

    Technical Specifications

    Software Version WinCC flexible 2008
    Product Family SIMATIC WinCC flexible
    License Type Single-user license
    Compatible PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces Supported MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Supported HMI Panels SIMATIC TP, OP, MP, Mobile Panel series
    Scripting Support VBScript
    Operating System Windows XP, Windows Vista, Windows 7
    Project Simulation Integrated software simulator included
    Language Support Multi-language project configuration
    Alarm Logging Supported
    Recipe Management Supported
    Trend Display Supported

    Common Error Codes & System Events

    Error 1920
    License not found or license server not reachable during software startup.
    Verify that the software license (Automation License Manager) is correctly installed and activated. Check that the USB dongle or license key is present and recognized by the system.
    Error 1722
    Installation error indicating a problem with the Windows Installer package during setup.
    Run the installer as administrator, ensure all prerequisite components (.NET Framework, MSXML) are installed, and disable antivirus software temporarily during installation.
    Compiler Error
    Project compilation fails due to invalid tag references, missing connections, or unsupported functions for the target panel.
    Review the compiler output log, correct all invalid tag assignments, verify the target panel type is correctly configured, and ensure all referenced connections exist.
    Communication Error
    Loss of communication between the HMI panel and the PLC during runtime or download.
    Check physical cable connections, verify PLC address settings match the project configuration, and confirm the correct communication driver is selected in the project.
    Download Error
    Project transfer to the HMI panel fails during the download process.
    Ensure the panel is in transfer mode, verify the correct transfer channel (USB, Ethernet, or MPI) is selected, and check that the panel firmware version is compatible with the WinCC flexible 2008 project version.
    Simulation Abort
    The integrated simulator terminates unexpectedly during project testing.
    Check for unsupported functions or scripts in the project, reduce project complexity if memory limits are exceeded, and ensure the PC meets the minimum system requirements for the software.
    Tag Limit Exceeded
    The number of configured tags in the project exceeds the limit permitted by the installed license edition.
    Upgrade the license to a higher edition that supports more tags, or reduce the number of tags in the project to comply with the current license restrictions.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP177, TP270, TP370, OP170, OP270, MP270, MP370, Mobile Panel 170, and Mobile Panel 270 series, among others.

    Is WinCC flexible 2008 compatible with TIA Portal projects?

    No, WinCC flexible 2008 is not directly compatible with TIA Portal. Siemens provides a migration tool to convert WinCC flexible projects into WinCC (TIA Portal) format, but the two engineering environments are separate.

    What operating systems are supported for installing WinCC flexible 2008?

    WinCC flexible 2008 supports installation on Windows XP (SP2 or later), Windows Vista, and Windows 7. It is not officially supported on Windows 10 or Windows 11.

    Does WinCC flexible 2008 include a simulator for testing projects without hardware?

    Yes, WinCC flexible 2008 includes an integrated simulation function that allows engineers to test and validate HMI projects on a PC without requiring a physical panel or PLC connection.

    What communication protocols can be configured in WinCC flexible 2008?

    WinCC flexible 2008 supports MPI, PROFIBUS DP, and Industrial Ethernet (TCP/IP) communication protocols for connecting HMI panels to SIMATIC PLCs and other compatible controllers.

    Troubleshooting

    Software fails to start after installation and displays a license error

    Open the Automation License Manager to check whether a valid license for WinCC flexible 2008 is installed and active on the machine.

    Install the correct license using the Automation License Manager. If using a USB dongle, ensure it is connected and recognized by Windows before launching the software.

    Project download to HMI panel fails with a connection timeout

    Verify the transfer channel settings in the project match the physical connection method (USB, Ethernet, or MPI/PROFIBUS adapter). Check that the panel is set to transfer mode.

    Set the HMI panel to transfer mode via the Start Center, confirm the correct COM port or IP address is configured in the transfer settings, and retry the download.

    Compiler reports errors on tags that appear correctly configured

    Check whether the target panel type selected in the project matches the actual hardware. Tag limits and supported functions vary between panel types and license editions.

    Verify the correct panel type is selected under project properties, remove any unsupported function blocks, and ensure the number of tags does not exceed the license limit.

    WinCC flexible 2008 installation fails partway through on Windows 7

    Check the installation log for missing prerequisites such as .NET Framework 2.0, MSXML 6.0, or Visual C++ redistributables, which are required by the installer.

    Install all required prerequisites manually before running the WinCC flexible 2008 installer. Run the setup executable with administrator privileges and disable User Account Control (UAC) temporarily if needed.

    Runtime simulation crashes when testing scripts

    Review VBScript code in the project for syntax errors, infinite loops, or calls to unsupported runtime functions that are not available in the simulator environment.

    Correct any script errors identified in the output window, add error handling to VBScript routines, and test scripts incrementally to isolate the cause of the crash.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart