• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BL07-5AV0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BL07-5AV0 WinCC flexible 2007

    € 2.995,00

    Reset
    Clear
    SKU: 6AV6381-2BL07-5AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BL07-5AV0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC range.

    WinCC flexible 2007 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels up to Multi Panels and PC-based runtime systems. The software provides tag management, alarm logging, trend displays, recipe management, and report generation capabilities. It supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces, and includes tools for project migration from earlier ProTool and WinCC flexible versions.

    WinCC flexible 2007 is widely used in manufacturing automation, process control, and machine building applications where operator visualization and control are required. It is suitable for industries including automotive, food and beverage, packaging, and general factory automation. The software enables engineers to develop standardized HMI projects that can be deployed across multiple panel types within a single project framework.

    Technical Specifications

    Software Version WinCC flexible 2007
    Software Type Engineering Software / HMI Configuration Tool
    License Type Single-user license
    Compatible HMI Devices SIMATIC Micro Panels, OP/TP series, Multi Panels, MP series, PC-based runtime
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces Supported MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Project Migration ProTool, WinCC flexible 2004/2005/2007
    Languages Supported Up to 32 project languages
    Certifications CE
    Series/Product Family SIMATIC WinCC flexible

    Common Error Codes & System Events

    Error 1920
    Runtime license not found or invalid license key detected during startup.
    Verify that the correct license key is installed using the Automation License Manager. Reinstall or transfer the license if necessary.
    Error 1921
    License has expired or is no longer valid for the installed software version.
    Check the license validity period in the Automation License Manager and renew or upgrade the license as required.
    Error 2503
    Project compilation failed due to inconsistent tag or screen configuration.
    Review the compiler output log, correct any invalid tag references or missing screen objects, and recompile the project.
    Error 2504
    Communication driver not found or not properly installed for the configured PLC connection.
    Reinstall the WinCC flexible software including all communication drivers, and verify the PLC connection settings in the project.
    Error 1722
    Installation error during WinCC flexible setup, typically caused by missing Windows components or conflicts with existing software.
    Ensure all required Windows components (e.g., .NET Framework, DCOM settings) are correctly installed and resolve any conflicting software before reinstalling.
    Runtime Error: Tag Connection Lost
    Runtime loses communication with the configured PLC, resulting in tags showing invalid or substitution values.
    Check physical network connections, verify PLC address settings, and confirm that the communication driver is active and correctly configured in the runtime project.
    Error 1603
    General installation failure during WinCC flexible software setup.
    Check Windows Event Viewer for detailed error information, ensure sufficient disk space and administrator privileges, and retry the installation.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports a wide range of SIMATIC HMI devices including Micro Panels (KTP series), Operator Panels (OP series), Touch Panels (TP series), and Multi Panels (MP series). PC-based runtime systems running WinCC flexible Runtime are also supported.

    Which PLC families can WinCC flexible 2007 communicate with?

    WinCC flexible 2007 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet. Third-party PLC connectivity may also be possible via OPC.

    Is WinCC flexible 2007 compatible with Windows 10?

    WinCC flexible 2007 was designed for Windows XP, Windows Vista, and Windows 7 (32-bit). It is not officially supported on Windows 10; users requiring Windows 10 compatibility should consider migrating to TIA Portal with WinCC.

    Can projects created in WinCC flexible 2007 be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. However, manual adjustments are typically required after migration due to differences in functionality and device support.

    What is the Automation License Manager and is it required for this software?

    The Automation License Manager is Siemens' tool for managing software licenses and is required to activate and run WinCC flexible 2007. The license key supplied with 6AV6381-2BL07-5AV0 must be registered through this tool before the software can be used.

    Troubleshooting

    WinCC flexible 2007 fails to install on the engineering PC

    Check the Windows Event Viewer for installation error codes. Verify that the operating system version is compatible (Windows XP/Vista/7 32-bit) and that all prerequisite components such as .NET Framework are installed.

    Install all required Windows updates and prerequisites, ensure the user account has administrator privileges, disable antivirus software temporarily during installation, and retry the setup.

    Project does not compile and reports tag or screen errors

    Open the compiler output window and review all listed errors. Identify any broken tag references, missing communication drivers, or incorrectly configured screen objects.

    Correct all flagged errors in the project editor, ensure all referenced tags exist and are correctly typed, and recompile the project. Refer to the WinCC flexible online help for guidance on specific error messages.

    Runtime communication with PLC is lost intermittently

    Check the physical Ethernet or PROFIBUS cable connections between the HMI panel and PLC. Verify the PLC IP address or MPI/PROFIBUS address matches the configuration in the WinCC flexible project.

    Secure all cable connections, correct any address mismatches in the project connection settings, and check for network conflicts or duplicate addresses on the bus. Update communication drivers if necessary.

    License error appears when launching WinCC flexible or the runtime

    Open the Automation License Manager and check whether a valid license for WinCC flexible 2007 is present and assigned to the local machine. Look for expired or missing license entries.

    Transfer or reinstall the license using the Automation License Manager. If the license was stored on a USB dongle, ensure the dongle is connected. Contact Siemens support if the license key is corrupted or lost.

    Existing ProTool or older WinCC flexible project does not open correctly after migration

    Attempt to open the project and note any migration warnings or errors reported by the software. Check whether the project was created in a version earlier than WinCC flexible 2004.

    Use the integrated migration wizard to convert the project, address all reported compatibility issues manually, and verify all screens, tags, and alarms after migration. Refer to the WinCC flexible migration documentation for version-specific guidance.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart