• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BC08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BC08-0AX0 WinCC flexible 2008

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6381-2BC08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BC08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible SCADA and HMI engineering software family. This product provides the engineering environment used to configure, program, and commission Siemens HMI panels such as the TP, OP, MP, and Mobile Panel series. It is designed to run on a standard engineering PC and integrates tightly with the Siemens SIMATIC automation ecosystem.

    WinCC flexible 2008 offers a comprehensive set of tools for creating HMI visualization projects, including tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It includes a simulation function that allows projects to be tested on the engineering PC without requiring physical hardware, and supports multi-language project engineering for international deployments.

    This software is used across a wide range of industrial automation applications including machine tool control, packaging machinery, process plants, and conveyor systems. It is particularly suited for OEMs and system integrators who need to develop and maintain HMI projects for Siemens panel hardware. The 2008 version represents a mature release of the WinCC flexible platform before the transition to the TIA Portal engineering framework.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user engineering license
    Compatible HMI Hardware SIMATIC HMI TP, OP, MP, Mobile Panel series
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces Supported MPI, PROFIBUS DP, Industrial Ethernet
    Scripting Support VBScript
    Simulation Integrated PC-based project simulation
    Operating System Windows XP, Windows Vista, Windows 7
    Series/Product Family WinCC flexible
    Language Support Multi-language project engineering
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000000
    Runtime communication error between HMI panel and PLC. The configured connection to the controller cannot be established.
    Check physical communication cable and interface settings. Verify PLC address, baud rate, and network parameters match the project configuration.
    Event ID: 1000002
    Tag read/write error. A configured tag could not be read from or written to the PLC.
    Verify the tag address exists in the PLC program and that the data type matches the HMI tag configuration. Check PLC is in RUN mode.
    Event ID: 1000003
    Connection timeout. Communication to the PLC was lost during runtime.
    Check network cabling and switch/hub integrity. Verify PLC is powered and operational. Review connection timeout parameters in the project settings.
    Event ID: 1000010
    License not found. The software could not detect a valid license for the installed WinCC flexible version.
    Insert the correct license key or USB dongle. Use the Siemens Automation License Manager (ALM) to verify and transfer the license.
    Event ID: 1000020
    Project transfer error. Download of the HMI project to the target panel failed.
    Check the transfer cable or Ethernet connection between the engineering PC and the HMI panel. Ensure the panel is in transfer mode and the correct transfer channel is selected.
    Event ID: 1000030
    Compilation error. The project could not be compiled due to configuration inconsistencies.
    Review the compiler output log for specific errors. Correct invalid tag references, missing screen objects, or unsupported functions for the target HMI device.
    Event ID: 1000040
    Incompatible project version. The project was created with a different version of WinCC flexible and cannot be opened directly.
    Use the WinCC flexible migration tool to convert the project to the current version. Back up the original project before migration.

    Frequently Asked Questions

    Which Siemens HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. It does not support the newer Comfort Panel series, which requires TIA Portal.

    Is WinCC flexible 2008 compatible with Windows 10?

    WinCC flexible 2008 was designed for Windows XP, Vista, and Windows 7. It is not officially supported on Windows 10, and installation on Windows 10 may result in compatibility issues or require additional configuration.

    Can WinCC flexible 2008 communicate with S7-1500 PLCs?

    No, WinCC flexible 2008 does not natively support the S7-1500 series. Communication with S7-1500 controllers requires TIA Portal with WinCC (TIA Portal).

    Does this license include runtime software for the HMI panel?

    The engineering license (6AV6381-2BC08-0AX0) covers project creation and download. Runtime software is embedded in the HMI panel firmware and does not require a separate runtime license for the panel itself.

    What is the difference between WinCC flexible 2008 and TIA Portal WinCC?

    WinCC flexible 2008 is the standalone legacy engineering tool for older SIMATIC HMI panels, while TIA Portal WinCC is the successor integrated within the TIA Portal framework and supports newer hardware including Comfort Panels and S7-1500 PLCs.

    Troubleshooting

    Software installation fails or aborts during setup

    Check Windows version compatibility and whether prerequisite components such as Microsoft .NET Framework and SQL Server are installed. Review the installation log file for specific error messages.

    Install all required prerequisites listed in the WinCC flexible 2008 readme. Run the installer as Administrator and disable antivirus software temporarily during installation. Ensure the operating system is Windows XP SP3 or Windows 7 SP1.

    License error displayed when launching WinCC flexible 2008

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2008 is listed and active.

    Transfer the correct license using ALM from the license storage medium (USB dongle or license disk). Ensure the license matches the installed software edition (e.g., Standard, Advanced, or Compact).

    Project cannot be transferred to the HMI panel

    Verify the transfer channel settings in the project match the physical connection being used (USB, Ethernet, or serial). Check that the HMI panel is set to transfer mode.

    Set the HMI panel to transfer mode via the Start Center or Control Panel on the device. Confirm IP address or COM port settings are correctly configured in the WinCC flexible transfer dialog.

    Compilation errors when building the project

    Review the output window for specific error messages referencing screen objects, tags, or scripts. Identify whether errors relate to unsupported functions for the selected target device.

    Correct all flagged configuration errors in the output log. Ensure the target device type selected in the project matches the physical HMI hardware. Remove or replace any functions not supported by the target panel.

    Existing project cannot be opened after software update

    WinCC flexible may prompt that the project was created with an older version and requires migration. Check the project version against the installed software version.

    Use the integrated migration wizard in WinCC flexible 2008 to upgrade the project file. Always create a backup copy of the original project before performing migration.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart