• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BC08-0AH0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BC08-0AH0 WinCC flexible 2008

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6381-2BC08-0AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BC08-0AH0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is designed for use with the full range of Siemens operator panels and touch displays.

    WinCC flexible 2008 offers a comprehensive set of engineering tools for creating HMI projects, including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It includes multi-language project support, library management, and integration with STEP 7 for seamless project data exchange. The software runs on standard Windows-based engineering PCs and supports migration of projects from earlier WinCC flexible versions.

    WinCC flexible 2008 is widely used in manufacturing, process automation, and machine building industries where SIMATIC HMI panels such as the TP, OP, MP, and Mobile Panel series are deployed. It is suitable for applications ranging from small standalone machines to distributed production lines requiring centralized visualization and control. The software is particularly valued in environments already standardized on Siemens SIMATIC automation infrastructure.

    Technical Specifications

    Software Version WinCC flexible 2008
    Product Family SIMATIC WinCC flexible
    License Type Single-user engineering license
    Supported PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Integration STEP 7 integration supported
    Project Migration Migration from WinCC flexible 2004, 2005, 2007
    Language Support Multi-language project engineering
    Alarm Logging Supported
    Recipe Management Supported
    Trend Display Supported
    Certifications CE
    Delivery Format DVD with license key

    Common Error Codes and System Events

    Configuration Error: Tag Limit Exceeded
    The number of configured tags in the project exceeds the licensed tag count for the installed edition.
    Reduce the number of tags in the project or upgrade to a higher WinCC flexible edition with a larger tag count.
    Runtime License Not Found
    The WinCC flexible Runtime license is missing or not activated on the target device.
    Transfer the correct runtime license to the target HMI panel using the Automation License Manager.
    Communication Error: Connection to PLC Failed
    The HMI project cannot establish a connection to the configured SIMATIC PLC.
    Verify network settings, MPI/PROFIBUS address configuration, and physical cable connections. Check PLC communication parameters in the project.
    Project Compilation Error
    The project contains configuration errors that prevent successful compilation.
    Review the output window for specific error messages, correct tag references, screen objects, or script errors, then recompile.
    Transfer Error: Target Device Not Reachable
    The engineering PC cannot reach the target HMI panel during project transfer.
    Check the transfer cable or Ethernet connection, ensure the HMI panel is in transfer mode, and verify IP address or MPI address settings.
    Automation License Manager: License Invalid
    The software license detected by the Automation License Manager is invalid, expired, or bound to a different hardware dongle.
    Check the USB dongle or software license key, re-activate the license via the Automation License Manager, or contact Siemens support for license recovery.
    Version Mismatch Warning
    The project was created with a different version of WinCC flexible and may contain incompatible elements.
    Perform a project migration using the built-in migration wizard and review any elements flagged as incompatible after migration.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP, OP, MP, and Mobile Panel series, as well as PC-based runtime systems running WinCC flexible Runtime.

    Is WinCC flexible 2008 compatible with TIA Portal projects?

    No, WinCC flexible 2008 is not directly compatible with TIA Portal. Projects created in WinCC flexible 2008 can be migrated to TIA Portal using the TIA Portal migration tool, but the two environments are separate.

    What PLCs can be connected using WinCC flexible 2008?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces.

    Can WinCC flexible 2008 run on Windows 10?

    WinCC flexible 2008 was designed for Windows XP, Vista, and Windows 7 (32-bit). It is not officially supported on Windows 10, and compatibility issues are likely without virtualization.

    Does this license include the WinCC flexible Runtime?

    The engineering software license (6AV6381-2BC08-0AH0) covers the configuration environment. Runtime licenses for target HMI panels are separate and must be ordered or transferred individually depending on the panel type.

    Troubleshooting

    Project transfer to HMI panel fails repeatedly

    Check whether the HMI panel is in transfer mode and verify the communication channel settings (Ethernet IP address or MPI/PROFIBUS address) in both the panel loader and the project transfer settings.

    Set the HMI panel to transfer mode via the Start Center or loader menu, confirm matching IP or bus addresses, and retry the transfer. If using Ethernet, ensure no firewall is blocking the connection on the engineering PC.

    WinCC flexible 2008 fails to install or throws a license error on startup

    Check the Automation License Manager to verify that the license is present, valid, and not bound to a missing hardware dongle. Confirm the installation media matches the licensed edition.

    Re-insert the USB license dongle if applicable, or use the Automation License Manager to repair or reactivate the software license. Reinstall the software if the installation is corrupted.

    PLC communication is not established at runtime on the HMI panel

    Verify the communication driver settings in the WinCC flexible project, including PLC type, interface type, and address parameters. Check physical wiring and confirm the PLC is in RUN mode.

    Correct the communication parameters in the project, recompile, and retransfer to the panel. Replace or reseat communication cables and confirm correct termination resistors are in place on PROFIBUS networks.

    Alarm messages are not displayed on the HMI panel

    Check that alarm tags are correctly configured and linked to the appropriate PLC bit addresses. Verify that the alarm view object is placed on the correct screen and that the alarm class is enabled.

    Review alarm configuration in the WinCC flexible project, ensure correct tag connections, recompile the project, and retransfer to the panel. Confirm the PLC program is setting the expected alarm bits.

    Project migration from an older WinCC flexible version results in missing or broken screen elements

    Run the migration wizard and review the migration log for specific elements that could not be converted. Some objects from older versions may not have direct equivalents in WinCC flexible 2008.

    Manually recreate or reconfigure the flagged screen elements after migration. Refer to the WinCC flexible 2008 migration documentation for guidance on replacing deprecated objects.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart