
Siemens 6AV6381-2AB07-5AX3 WinCC flexible 2007
€ 840,00
The Siemens 6AV6381-2AB07-5AX3 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is used to create visualization projects for industrial automation systems.
WinCC flexible 2007 offers a comprehensive engineering environment with support for a wide range of Siemens HMI hardware, including the OP, TP, MP, and Mobile Panel series. The software supports multiple communication drivers enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and other controllers via MPI, PROFIBUS DP, and Industrial Ethernet. It includes features such as recipe management, trend displays, alarm logging, user administration, and multi-language project support, making it a capable platform for complex visualization tasks.
This software is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is particularly suited for OEMs and system integrators who need to develop standardized HMI solutions across multiple panel types from a single engineering tool. Industries such as automotive, food and beverage, chemical processing, and packaging machinery commonly deploy WinCC flexible 2007 for operator interface development.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| License Type | Single-user engineering license |
| Compatible HMI Hardware | SIMATIC OP, TP, MP, Mobile Panel series |
| Controller Compatibility | SIMATIC S7-200, S7-300, S7-400, WinAC |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Project Languages | Up to 32 languages per project |
| Series/Product Family | SIMATIC WinCC flexible |
| Alarm Management | Supported (discrete and analog alarms) |
| Recipe Management | Supported |
| Trend Display | Supported |
| User Administration | Supported |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000001
- Communication error between engineering station and HMI panel during project download.
Check the communication cable and interface settings. Verify the correct communication driver is selected and that the panel IP address or MPI address matches the project configuration. - Event ID: 1000002
- License not found or license key invalid for WinCC flexible engineering software.
Verify the license dongle (USB or software license) is correctly installed. Use the Siemens Automation License Manager (ALM) to check license status and re-activate if necessary. - Event ID: 1000010
- Project compilation error due to inconsistent configuration or missing tag references.
Review the compiler output log in the engineering software. Correct all referenced errors such as missing tags, invalid screen references, or unsupported functions for the target panel type. - Event ID: 1000020
- Runtime error on HMI panel: connection to PLC lost during operation.
Check the physical communication link between the panel and PLC. Verify PLC is powered and running. Check network or bus configuration parameters in the project. - Event ID: 1000030
- Insufficient memory on target HMI device for the compiled project.
Reduce project size by removing unused screens, images, or scripts. Check the memory requirements of the target panel and optimize the project accordingly. - Event ID: 1000040
- Version conflict: project was created with a different version of WinCC flexible than the installed runtime.
Ensure the engineering software version matches the runtime version on the HMI panel. Upgrade or downgrade the panel runtime firmware as required, or recompile the project with the correct software version. - Event ID: 1000050
- Script or VB script execution error during runtime.
Review the script code for syntax or logic errors. Use the WinCC flexible diagnostic functions to identify the specific script and line causing the fault.
Frequently Asked Questions
What HMI panels are compatible with WinCC flexible 2007?
WinCC flexible 2007 supports a wide range of Siemens SIMATIC HMI panels including the OP 77, TP 177, MP 277, MP 377, Mobile Panel 177, and other panels in the OP, TP, and MP series. Compatibility depends on the specific edition of the software (Micro, Compact, Standard, or Advanced).
What PLC systems can WinCC flexible 2007 communicate with?
WinCC flexible 2007 supports communication with SIMATIC S7-200, S7-300, S7-400, and WinAC controllers via MPI, PROFIBUS DP, and Industrial Ethernet. Additional third-party controllers may be supported through optional communication drivers.
Does WinCC flexible 2007 require a hardware dongle for licensing?
Licensing for WinCC flexible 2007 is managed through the Siemens Automation License Manager (ALM). Depending on the license variant, it may use a USB hardware dongle or a software-based license tied to the engineering PC.
Can projects created in WinCC flexible 2007 be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible projects to be imported and converted. However, manual adjustments may be required after migration due to differences in functionality between the two platforms.
What operating systems are supported for running WinCC flexible 2007?
WinCC flexible 2007 is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7. It is not officially supported on Windows 8, Windows 10, or later operating systems.
Troubleshooting
Project download to HMI panel fails with a communication error
Check the connection type configured in the project (USB, Ethernet, or MPI/PROFIBUS). Verify the cable is properly connected and the panel is in transfer mode. Confirm the PC interface settings match the selected communication path.
Set the HMI panel to transfer mode manually via the panel's start center. Ensure the correct PC adapter (e.g., PC Adapter USB for MPI) is selected in the WinCC flexible transfer settings. Reinstall the communication driver if the port is not recognized.
WinCC flexible 2007 software fails to start or crashes on launch
Check the Windows Event Viewer for application errors. Verify that the Automation License Manager service is running and a valid license is present. Confirm the PC meets the minimum hardware requirements.
Repair or reinstall the WinCC flexible 2007 installation via the setup program. Ensure all required Microsoft redistributables and .NET Framework versions are installed. Re-activate the license using the Automation License Manager if it shows as invalid.
Compiled project exceeds the memory capacity of the target panel
Review the project memory usage report generated during compilation. Identify large image files, unused screens, or excessive script content that may be consuming memory.
Optimize image files by reducing resolution or color depth. Remove unused screens, tags, and scripts. Consider upgrading to a target panel with greater memory capacity if optimization is insufficient.
HMI panel loses connection to PLC intermittently during runtime
Check the physical communication medium for loose connectors or cable damage. Review the PLC CPU diagnostic buffer for communication faults. Verify the configured connection parameters such as IP address, subnet mask, and MPI address.
Replace or reseat communication cables and connectors. Adjust the communication timeout settings in the WinCC flexible project if the network has high latency. Ensure the PLC program is not overloading the communication interface with excessive data requests.
Alarm messages are not displayed on the HMI panel during runtime
Verify that the alarm tags are correctly configured and linked to the appropriate PLC data addresses. Check that the alarm view or alarm window control is present on the relevant screens. Confirm the PLC is writing the expected values to the alarm trigger bits.
Review the alarm configuration in WinCC flexible and confirm tag addresses match the PLC program. Ensure the alarm view control is correctly placed and configured on the HMI screen. Test alarm triggering by manually setting the alarm bits in the PLC using a programming tool.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page



