• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2HG08-0AA0 WinCC Runtime
    Awaiting product image

    Siemens 6AV6372-2HG08-0AA0 WinCC Runtime

    € 2.154,50

    Reset
    Clear
    SKU: 6AV6372-2HG08-0AA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2HG08-0AA0 is a WinCC Runtime software license belonging to Siemens' SIMATIC WinCC product family, which is a professional SCADA and HMI visualization platform for PC-based operator control and monitoring systems. This specific part number corresponds to a WinCC Runtime package with a defined power tag license, enabling process visualization and data acquisition on standard industrial PCs or SIMATIC Panel PCs. It is part of the broader SIMATIC HMI software ecosystem and is designed to run on Windows-based operating systems in industrial environments.

    The WinCC Runtime software provides a comprehensive set of features including process visualization, alarm management, trend displays, reporting, and historical data archiving. It supports a wide range of communication interfaces and drivers, enabling connectivity to SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs via PROFIBUS, PROFINET, and MPI, as well as third-party systems through OPC DA and OPC UA interfaces. The runtime environment supports scripting via VBScript and C-Script for custom automation logic, and includes a tag-based licensing model where the number of process variables (power tags) determines the license tier.

    WinCC Runtime is widely deployed in manufacturing, process industries, energy management, water treatment, and building automation applications where centralized supervisory control and data acquisition are required. Its compatibility with the broader Siemens TIA Portal and SIMATIC IT ecosystem makes it suitable for integration into large-scale plant automation architectures. The software is particularly well-suited for applications requiring robust data logging, multi-user access, and long-term process data archiving.

    Technical Specifications

    Software Type SCADA / HMI Runtime Software
    Product Family SIMATIC WinCC
    License Type Runtime License (Power Tag-based)
    Operating System Compatibility Windows (32/64-bit, industrial versions)
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC DA, OPC UA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500
    Scripting Support VBScript, C-Script
    Archiving Process data and alarm archiving supported
    Multi-User Support Yes (server/client architecture)
    TIA Portal Integration Compatible
    Certifications CE
    Delivery Format Software license (electronic or physical media)

    Common Error Codes and System Events

    Event ID: 1000000
    WinCC Runtime startup error — the runtime could not be initialized, often due to a missing or invalid license.
    Verify that the WinCC license is correctly installed using the Siemens Automation License Manager (ALM). Ensure the license matches the number of configured power tags.
    Event ID: 1000008
    Communication error to PLC — the configured connection to the SIMATIC controller cannot be established.
    Check network cabling and PROFINET/PROFIBUS configuration. Verify PLC IP address or MPI address settings in WinCC channel configuration. Confirm the PLC is in RUN mode.
    Event ID: 1000040
    Tag logging error — process data could not be written to the archive database.
    Check available disk space on the archive drive. Verify SQL Server or WinCC database service is running. Review archive configuration for correct tag assignments.
    Event ID: 1000112
    Alarm logging failure — alarm events are not being recorded to the alarm archive.
    Ensure the alarm logging component is active in WinCC Explorer. Check database connectivity and available storage. Restart the WinCC alarm logging service if necessary.
    License Error
    No valid WinCC Runtime license found or the number of configured power tags exceeds the licensed quantity.
    Open the Automation License Manager, verify the installed license key, and ensure the power tag count in the project does not exceed the licensed limit. Transfer or upgrade the license as needed.
    OPC Connection Error
    OPC DA or OPC UA client/server connection cannot be established between WinCC and a third-party system.
    Verify OPC server address and namespace configuration. Check DCOM settings for OPC DA connections. Ensure firewall rules permit OPC UA port (default 4840) for OPC UA connections.
    Database Overflow Warning
    The WinCC archive database is approaching or has reached its maximum configured size.
    Increase the maximum archive size in the tag logging or alarm logging settings, or configure automatic data backup and deletion of older archive segments to free space.

    Frequently Asked Questions

    What is the power tag capacity of the 6AV6372-2HG08-0AA0 license?

    The 6AV6372-2HG08-0AA0 corresponds to a WinCC Runtime license with a specific power tag count defined by the Siemens ordering system. Consult the Siemens SIMATIC WinCC catalog or the Automation License Manager to confirm the exact tag count for this part number.

    Which PLCs are compatible with WinCC Runtime 6AV6372-2HG08-0AA0?

    WinCC Runtime is compatible with SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs via PROFIBUS, PROFINET, and MPI. Third-party PLCs and systems can be connected via OPC DA or OPC UA interfaces.

    Does this WinCC Runtime license support multi-user (client/server) operation?

    Yes, WinCC Runtime supports a server/client architecture, allowing multiple operator stations to connect to a central WinCC server. Additional client licenses may be required depending on the number of connected clients.

    Is the 6AV6372-2HG08-0AA0 compatible with TIA Portal?

    WinCC Runtime is part of the SIMATIC HMI ecosystem and can be integrated with TIA Portal projects. However, WinCC Runtime (PC-based) is distinct from WinCC Basic/Comfort/Advanced used for panel-based HMIs in TIA Portal; compatibility depends on the specific project configuration.

    What operating system is required to run this WinCC Runtime software?

    WinCC Runtime requires a Windows operating system, typically Windows 7, Windows 10, or Windows Server editions as specified by Siemens for the respective WinCC version. Industrial-grade PCs or SIMATIC Panel PCs are recommended for production environments.

    Troubleshooting

    WinCC Runtime fails to start and displays a license error on launch

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC Runtime license is present and not expired or transferred. Verify the power tag count of the installed license matches or exceeds the project requirements.

    Install or transfer the correct WinCC Runtime license using the ALM tool. If using a USB dongle, ensure it is properly connected. If the license is on a hard disk, verify it has not been corrupted by a system crash or disk cloning operation.

    No communication between WinCC Runtime and the SIMATIC PLC

    Check the WinCC channel diagnostics in WinCC Explorer under 'Tag Management'. Verify the configured PLC address (IP for PROFINET, MPI address for MPI) matches the actual controller settings. Use PING or SIMATIC NET diagnostic tools to confirm network connectivity.

    Correct the PLC address in the WinCC channel configuration. Ensure the correct communication driver (e.g., SIMATIC S7 Protocol Suite or S7-1500 channel) is installed and active. Check that the PLC is powered on and in RUN mode, and that no firewall is blocking the communication port.

    Historical trend data or archive values are missing or not updating

    Check the WinCC Tag Logging component status in WinCC Explorer. Verify the SQL Server service (used by WinCC for archiving) is running via Windows Services. Check available disk space on the archive storage drive.

    Restart the WinCC Tag Logging service and SQL Server service if they have stopped. Free up disk space if the archive drive is full. Review the archive configuration to ensure tags are correctly assigned to the logging group and the logging cycle is properly set.

    Alarm messages are not appearing in the WinCC alarm view at runtime

    Verify that the WinCC Alarm Logging component is enabled and active in WinCC Explorer. Check that alarm tags are correctly configured with valid limit values and that the associated PLC tags are communicating correctly.

    Activate the Alarm Logging component in WinCC Explorer if it is disabled. Confirm that the alarm trigger tags are receiving live values from the PLC. Review alarm class and group configurations to ensure alarms are not filtered out in the runtime alarm view control.

    WinCC Runtime performance is slow or the screen refresh rate is very low

    Check CPU and RAM utilization on the host PC using Windows Task Manager. A high number of active power tags, frequent archive writes, or insufficient hardware resources can degrade runtime performance. Also check for excessive VBScript or C-Script execution cycles.

    Upgrade the host PC hardware if it does not meet the minimum requirements for the installed WinCC version and tag count. Optimize script execution by reducing cycle times for non-critical scripts. Reduce archive logging frequency for tags that do not require high-resolution data.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart