Siemens 6AV6372-2DF07-4FH4 SIMATIC WinCC
€ 2.495,00
The Siemens 6AV6372-2DF07-4FH4 is a software license package belonging to the SIMATIC WinCC family of SCADA and HMI visualization software developed by Siemens. WinCC (Windows Control Center) is a powerful process visualization system designed for use on PC-based operator stations, enabling comprehensive monitoring and control of industrial automation processes. This part number corresponds to a specific WinCC runtime or configuration software edition with a defined tag count or functional scope.
The WinCC software platform provides a rich set of features including process visualization, alarm management, trend display, reporting, and historical data archiving. It supports a wide range of communication interfaces and drivers for connecting to Siemens SIMATIC S7 PLCs via PROFIBUS, PROFINET, and MPI, as well as third-party controllers via OPC DA/UA. The software runs on standard Windows-based industrial PCs and panel PCs, offering scalability from small standalone installations to large distributed multi-client/server architectures.
WinCC is widely deployed across industries including automotive manufacturing, chemical processing, water and wastewater treatment, food and beverage production, and energy management. It is particularly suited for applications requiring detailed process visualization, data logging, and integration with higher-level MES or ERP systems via open interfaces. The software's compatibility with the broader Siemens TIA Portal ecosystem makes it a common choice for facilities already operating SIMATIC automation infrastructure.
Technical Specifications
| Software Family | SIMATIC WinCC |
|---|---|
| Software Type | SCADA / HMI Visualization Software |
| Operating System | Windows (32/64-bit, version dependent on release) |
| Communication Interfaces | PROFIBUS, PROFINET, MPI, OPC DA, OPC UA |
| PLC Compatibility | SIMATIC S7-300, S7-400, S7-1200, S7-1500, and third-party via OPC |
| Architecture | Single-user / Client-Server scalable |
| Alarm Management | Integrated alarm logging and archiving |
| Trend Display | Online and historical trend curves |
| Data Archiving | Process value and alarm archiving with configurable retention |
| Certifications | CE |
| Series | SIMATIC WinCC V7 |
Common Error Codes & System Events
- Event ID: 1000000
- WinCC Runtime startup failure. The runtime application could not be initialized correctly.
Check Windows Event Viewer for underlying errors. Verify that all required WinCC services are running and that the license dongle or software license is correctly installed. - Event ID: 1001
- Communication channel to PLC lost. The configured communication driver cannot establish or maintain a connection to the target controller.
Verify network connectivity, check IP address or PROFIBUS address configuration, confirm PLC is powered and running, and check driver configuration in WinCC Explorer. - Event ID: 2501
- License not found or license count exceeded. WinCC cannot find a valid license for the configured tag count or feature set.
Insert the correct USB license dongle or activate the software license via Siemens Automation License Manager. Verify the licensed tag count matches the project requirements. - Event ID: 10000
- Database connection error. WinCC cannot connect to the internal SQL Server database used for archiving.
Check that the Microsoft SQL Server instance used by WinCC is running. Restart the SQL Server service if necessary and verify database file integrity. - Event ID: 10241
- Archive backup failed. The process value or alarm archive could not be backed up to the configured path.
Verify that the backup target path exists and has sufficient disk space. Check Windows user permissions for the WinCC service account on the target directory. - Event ID: 1004
- Tag update timeout. One or more process tags did not receive an update within the configured cycle time.
Check PLC communication status, verify tag address configuration, and increase the acquisition cycle time if the PLC scan time is longer than the configured update interval. - Event ID: 2000
- Graphics Runtime error. A screen or picture object failed to load or render correctly.
Check for missing or corrupt picture files in the WinCC project directory. Recompile the affected screens in WinCC Graphics Designer and restart the runtime.
Frequently Asked Questions
What is the tag count or license scope of the 6AV6372-2DF07-4FH4?
The exact tag count and license scope are defined by the specific WinCC edition encoded in this part number. Refer to the Siemens Industry Mall or the accompanying license certificate to confirm the number of process tags and optional features included.
Is WinCC 6AV6372-2DF07-4FH4 compatible with SIMATIC S7-1500 PLCs?
Yes, SIMATIC WinCC V7 supports communication with S7-1500 PLCs via PROFINET and the SIMATIC S7 Protocol Suite driver. Ensure the correct driver version is installed and that the PLC firmware is compatible.
Can this WinCC software be used in a multi-client server architecture?
WinCC supports scalable architectures including multi-client/server configurations, but the specific number of clients and servers permitted depends on the license edition. Verify the license scope of this part number before deploying in a distributed architecture.
What operating system is required to run this WinCC software?
SIMATIC WinCC V7 requires a Windows operating system, typically Windows 7 Professional or Windows Server 2008 R2 and later versions, depending on the specific WinCC version. Refer to the Siemens compatibility list for the exact OS requirements for this release.
Does WinCC support OPC UA for third-party device integration?
Yes, SIMATIC WinCC V7 includes OPC DA server and client functionality, and OPC UA support is available as an add-on or in later versions. This allows integration with third-party PLCs, sensors, and MES systems that support the OPC standard.
Troubleshooting
WinCC Runtime does not start after installation
Check the Windows Event Viewer under Application and System logs for error messages related to WinCC services or SQL Server. Verify that the Automation License Manager detects a valid license.
Ensure the correct license dongle is connected or the software license is activated. Confirm that Microsoft SQL Server is installed and running, as WinCC depends on it for archiving. Reinstall WinCC if service registration errors are present.
No communication between WinCC and the SIMATIC S7 PLC
Open WinCC Explorer and check the channel diagnostics for the SIMATIC S7 Protocol Suite driver. Verify the configured PLC IP address or PROFIBUS address and confirm network connectivity using a ping test or STEP 7 / TIA Portal online diagnostics.
Correct any misconfigured connection parameters in the WinCC Tag Management. Ensure the network interface card is properly configured and that no firewall is blocking the communication port. Restart the WinCC channel driver after making changes.
Historical trend data or alarm archives are missing or incomplete
Check the WinCC Archive Manager and verify that the archive tags are correctly configured with appropriate acquisition cycles. Review disk space availability on the archive drive and check SQL Server database status.
Free up disk space if the archive drive is full. Verify archive configuration in WinCC Data Manager and ensure the SQL Server service is running without errors. If the database is corrupt, restore from the last valid backup.
WinCC screens display incorrectly or objects are missing at runtime
Compare the runtime display with the design in WinCC Graphics Designer. Check for missing linked files, dynamic scripts with errors, or ActiveX controls that are not registered on the runtime PC.
Recompile all affected screens in Graphics Designer and ensure all referenced files are present in the project directory. Register any missing ActiveX controls using regsvr32 and verify that all required WinCC options are licensed and installed.
WinCC project cannot be opened after a Windows update or PC migration
Check the WinCC version compatibility with the current Windows version. Verify that the SQL Server instance name and WinCC project database connection strings are intact after the system change.
Repair the WinCC installation using the original installation media if system files were affected. For PC migrations, use the WinCC project duplicator tool to correctly transfer the project and re-register the database on the new system.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page