• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2DF07-1HH4 SIMATIC HMI TP 177B
    Awaiting product image

    Siemens 6AV6372-2DF07-1HH4 SIMATIC HMI TP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6372-2DF07-1HH4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2DF07-1HH4 is a Touch Panel belonging to the SIMATIC HMI TP 177B series, manufactured by Siemens. It is a compact operator panel designed for machine-level visualization and control in industrial automation environments. The device features a color TFT touch screen and is configured for operation with the WinCC flexible runtime environment.

    The TP 177B panel offers a 5.7-inch TFT color display with a resolution of 320 x 240 pixels (QVGA) and supports 256 colors. It is equipped with MPI/PROFIBUS DP and RS-422/RS-485 interfaces for communication with Siemens S7 PLCs and third-party controllers. The unit operates on a 24 V DC supply and includes 512 KB user memory for project data, along with support for external memory expansion via a MultiMediaCard (MMC) slot. The panel runs on the Windows CE operating system and supports configuration via SIMATIC WinCC flexible 2004 or later.

    The TP 177B is widely used in machine building, packaging machinery, conveyor systems, and process automation where a compact yet capable HMI interface is required. Its robust construction and IP65 front protection rating make it suitable for installation in control cabinet doors exposed to dust and moisture. The panel is particularly common in applications requiring direct integration with Siemens S7-200, S7-300, and S7-400 PLC families.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels (QVGA)
    Display Colors 256 colors
    Display Type TFT color
    Touch Technology Resistive touch screen
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 6 W
    Communication Interface MPI/PROFIBUS DP, RS-422/RS-485
    Memory 512 KB user memory, MMC slot for expansion
    Operating System Windows CE
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front), IP20 (rear)
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. The configured connection to the controller cannot be established.
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to PLC interrupted during runtime. Communication was established but subsequently lost.
    Inspect cable integrity and connector seating. Check for electromagnetic interference sources near the communication cable. Verify PLC is still operational and not in STOP mode.
    Event ID: 20000
    Project download error. Transfer of the WinCC flexible project to the panel failed.
    Verify the transfer cable or network connection between the engineering PC and the HMI panel. Ensure the panel is in Transfer mode and that the correct COM port or IP address is selected in WinCC flexible.
    Event ID: 40000
    System memory low. Available user memory on the panel is insufficient for the loaded project.
    Reduce the project size by removing unused screens, images, or variables. Consider using an MMC card for extended storage. Ensure no unnecessary background applications are running.
    Event ID: 50000
    Operating system error. An internal software fault has occurred within the Windows CE runtime environment.
    Perform a warm restart of the panel. If the fault persists, perform a factory reset and reload the project. Check for firmware compatibility between the panel and the WinCC flexible project version.
    Event ID: 60000
    Configuration error detected. A mismatch exists between the loaded project configuration and the panel hardware.
    Verify that the project was compiled for the correct HMI device type (TP 177B). Recompile and re-download the project using the correct device template in WinCC flexible.
    Event ID: 70000
    Tag update error. One or more process tags cannot be read or written due to a configuration or communication issue.
    Check tag addressing in the WinCC flexible project. Verify that the PLC data blocks and memory addresses referenced by the tags exist and are accessible. Confirm communication link is active.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens 6AV6372-2DF07-1HH4?

    The TP 177B is compatible with Siemens S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It also supports third-party controllers via the RS-422/RS-485 serial interface using standard protocols.

    What software is required to program this HMI panel?

    The panel is configured using Siemens SIMATIC WinCC flexible 2004 or later versions. Projects are downloaded to the panel via the MPI interface or a serial transfer cable.

    What is the operating voltage for the 6AV6372-2DF07-1HH4?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid operational issues.

    Can the memory be expanded on this panel?

    Yes, the TP 177B supports memory expansion via a MultiMediaCard (MMC) slot, which can be used to store additional project data, recipes, and data logs.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV6372-2DF07-1HH4 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for installation in control cabinet doors.

    Troubleshooting

    Display remains blank after power on

    Measure 24 V DC at the power supply terminals on the rear of the panel. Check the internal fuse if accessible. Observe whether any LED indicators illuminate on the device.

    Verify and restore correct 24 V DC supply. If the supply is confirmed correct and the display remains blank, the backlight or internal power supply board may have failed and the unit should be sent for repair or refurbishment.

    Touch screen does not respond or responds inaccurately

    Attempt to recalibrate the touch screen through the Windows CE control panel or the SIMATIC HMI startup menu. Check for physical damage or contamination on the touch surface.

    Perform a touch screen recalibration via the panel's loader menu. Clean the screen surface with a soft, dry cloth. If calibration does not resolve the issue, the resistive touch overlay may be worn or damaged and require replacement.

    HMI cannot establish communication with the PLC

    Check MPI/PROFIBUS DP cable connections at both the panel and PLC ends. Verify bus termination is correctly applied at both ends of the network. Confirm that the PLC address in the HMI project matches the actual PLC configuration.

    Replace or reseat the communication cable. Correct any address mismatches in the WinCC flexible project and re-download. Ensure bus termination resistors are enabled only at the physical ends of the network segment.

    Project download fails from engineering PC to panel

    Confirm the panel is set to Transfer mode via the loader menu. Check the transfer cable connection and verify the correct COM port or transfer settings are selected in WinCC flexible on the PC.

    Restart the panel in Transfer mode and retry the download. Try a different transfer cable if available. Ensure the WinCC flexible version used is compatible with the firmware version on the panel.

    Panel repeatedly restarts or freezes during operation

    Check the 24 V DC supply for voltage fluctuations or drops under load. Review the loaded project for configuration errors or memory overload conditions. Check for overheating by verifying ambient temperature and ventilation around the panel.

    Stabilize the power supply and ensure it has sufficient current capacity. Reduce project complexity if memory usage is excessive. Ensure the installation environment does not exceed the 50 °C maximum operating temperature. Perform a firmware update if a known software issue is suspected.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart