
Siemens 6AV6372-2DF07-1CH4 WinCC flexible 2007
€ 1.111,00
The Siemens 6AV6372-2DF07-1CH4 is a software license for WinCC flexible 2007 Compact, part of Siemens' WinCC flexible engineering software family. This product provides the configuration and project engineering environment used to create visualization projects for Siemens HMI panels, including the OP, TP, MP, and Mobile Panel series. It is designed for use on standard engineering PCs running compatible Windows operating systems.
WinCC flexible 2007 Compact supports project creation for a defined range of smaller HMI devices, offering a streamlined feature set suited to compact panel configurations. The software integrates with the Siemens SIMATIC engineering environment and supports tag management, alarm logging, recipe handling, and screen navigation configuration. It communicates with target HMI hardware via standard interfaces such as MPI, PROFIBUS, and Ethernet, and supports project transfer via serial connection or network.
This software is used across a broad range of industrial automation applications where Siemens HMI panels are deployed, including machine tool control, packaging machinery, conveyor systems, and process automation. It is particularly suited to OEMs and system integrators who develop visualization solutions based on the SIMATIC HMI platform. The Compact edition is appropriate for smaller-scale projects where the full WinCC flexible Advanced feature set is not required.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| Edition | Compact |
| License Type | Single license |
| Compatible HMI Devices | SIMATIC HMI OP, TP, MP, Mobile Panel series (Compact-supported devices) |
| Communication Interfaces Supported | MPI, PROFIBUS DP, Ethernet |
| Operating System | Windows XP (SP2 or higher), Windows 2000 Professional |
| Integration | SIMATIC STEP 7, SIMATIC iMap |
| Project Transfer | Serial, MPI, PROFIBUS, Ethernet |
| Language Support | Multilingual project configuration |
| Series/Product Family | WinCC flexible |
| Certifications | CE |
Common Error Codes and Software Events
- Error 1920
- License not found or license server unreachable during software startup
Verify that the license key (Automation License Manager) is correctly installed on the engineering PC. Check that the USB dongle or software license is present and recognized. - Error 1722
- Installation error: Windows Installer package failure during setup
Ensure the PC meets minimum system requirements. Run the installer as Administrator and verify that no conflicting software versions are present before retrying installation. - Transfer Error: No connection to device
- Project transfer to HMI panel fails due to communication fault
Check physical cable connections and verify the correct communication interface (MPI, PROFIBUS, or Ethernet) is selected in the transfer settings. Confirm the HMI panel is in transfer mode. - Compiler Error: Tag limit exceeded
- Project compilation fails because the number of configured tags exceeds the Compact edition limit
Reduce the number of tags in the project to within the Compact edition limit, or upgrade to WinCC flexible Standard or Advanced edition. - Runtime Mismatch Warning
- The WinCC flexible runtime version on the target HMI panel does not match the project version
Update the HMI panel runtime to the version corresponding to WinCC flexible 2007, or recompile the project using a compatible software version. - Error: Inconsistent project data
- Project file is corrupted or contains inconsistent internal references
Use the project consistency check tool within WinCC flexible to identify and resolve inconsistencies. Restore from a backup project file if the errors cannot be resolved.
Frequently Asked Questions
Which HMI panels are supported by WinCC flexible 2007 Compact?
WinCC flexible 2007 Compact supports a defined subset of SIMATIC HMI panels, including smaller OP and TP series devices. For larger panels such as the MP277 or MP377, the Standard or Advanced edition is required.
Is WinCC flexible 2007 compatible with Windows 10?
WinCC flexible 2007 was designed for Windows XP and Windows 2000 Professional. It is not officially supported on Windows 10; for modern operating systems, Siemens recommends migrating to WinCC flexible 2008 or the current TIA Portal WinCC platform.
Can this software be integrated with SIMATIC STEP 7?
Yes, WinCC flexible 2007 supports integrated engineering within the SIMATIC Manager environment when STEP 7 is installed on the same PC, allowing shared tag databases and coordinated project management.
What is the difference between WinCC flexible Compact, Standard, and Advanced?
The Compact edition supports a limited number of tags and a restricted set of HMI devices, making it suitable for smaller projects. Standard and Advanced editions support larger tag counts, more device types, and additional features such as extended scripting and server functionality.
How is the license delivered for part number 6AV6372-2DF07-1CH4?
This part number corresponds to a software package that includes the installation media and a license managed via the Siemens Automation License Manager (ALM). The license must be activated and managed through the ALM tool installed on the engineering PC.
Troubleshooting
Software fails to start and displays a license error
Open the Siemens Automation License Manager and check whether a valid license for WinCC flexible 2007 Compact is listed and active.
If the license is missing or shows an error status, reinstall the license from the original media or transfer it from the authorized license storage location using the Automation License Manager.
Project transfer to HMI panel fails repeatedly
Verify the communication settings in the transfer dialog match the physical interface in use. Check that the HMI panel is powered and set to transfer mode, and that the cable or network connection is functional.
Correct the interface selection (MPI address, PROFIBUS address, or IP address), replace the communication cable if faulty, and retry the transfer. Ensure no firewall is blocking the connection for Ethernet transfers.
Compiled project generates unexpected compiler errors
Review the error output in the compiler log within WinCC flexible. Identify whether errors relate to tag limits, unsupported functions for the Compact edition, or missing device driver configurations.
Resolve tag count overruns by reducing configured tags, remove functions not supported in the Compact edition, and ensure the correct target device is selected in the project properties before recompiling.
WinCC flexible installation fails or rolls back
Check the Windows Event Viewer for installation error codes. Confirm the PC meets the minimum hardware and OS requirements and that no previous partial installation of WinCC flexible remains.
Uninstall any remnants of previous WinCC flexible installations using the Siemens uninstall tool, reboot the PC, and run the installer again with Administrator privileges.
Existing project cannot be opened after PC migration
Determine whether the project was created with a different version of WinCC flexible or if the license on the new PC does not match the required edition.
Install the matching WinCC flexible 2007 Compact version on the new PC, activate the license via the Automation License Manager, and then open the project. If the project was created with a higher edition, a license upgrade may be required.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page



