• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-1DF07-1AH0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6372-1DF07-1AH0 WinCC flexible 2007

    € 1.466,00

    Reset
    Clear
    SKU: 6AV6372-1DF07-1AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-1DF07-1AH0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This package is used to configure, program, and commission Siemens HMI panels and operator interface devices within the SIMATIC HMI product range. It is a full engineering tool designed for use on standard PC hardware running a compatible Windows operating system.

    WinCC flexible 2007 provides a comprehensive development environment for creating HMI visualization projects, supporting a wide range of Siemens operator panels including the TP, OP, MP, and Mobile Panel series. The software supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, enabling integration with SIMATIC S7-200, S7-300, S7-400, and other compatible controllers. It includes features such as tag management, alarm logging, trend displays, recipe management, and multi-language project support. The engineering environment is compatible with STEP 7 for integrated project handling.

    WinCC flexible 2007 is used across a broad range of industrial sectors including manufacturing, automotive, food and beverage, chemical processing, and water treatment. It is suited for machine-level HMI applications where operators require reliable visualization and control interfaces. The software enables engineers to develop scalable projects that can be deployed across multiple panel types with minimal reconfiguration.

    Technical Specifications

    Software Version WinCC flexible 2007
    Software Type Engineering Software / HMI Configuration Tool
    License Type Full License
    Compatible HMI Panels SIMATIC TP, OP, MP, Mobile Panel series
    Controller Compatibility SIMATIC S7-200, S7-300, S7-400, WinAC
    Communication Interfaces Supported PROFIBUS, PROFINET, MPI, Ethernet
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Integration Compatible with SIMATIC STEP 7
    Languages Supported Multi-language project support
    Series/Product Family WinCC flexible

    Common Error Codes and System Events

    Event ID: 1000
    License not found or invalid license key detected during software startup
    Verify that the correct license key is installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary.
    Event ID: 1001
    Communication error between WinCC flexible engineering station and HMI panel
    Check the physical connection cable and interface settings. Verify the correct communication driver and baud rate are configured in the project settings.
    Event ID: 1002
    Project compilation error due to invalid tag configuration
    Review the tag table for duplicate addresses or unsupported data types. Correct the offending entries and recompile the project.
    Event ID: 1003
    Transfer to HMI panel failed
    Ensure the panel is in transfer mode and the correct transfer channel (USB, Ethernet, or MPI) is selected. Check firewall settings on the engineering PC.
    Event ID: 1004
    Runtime simulation error — project cannot be simulated on PC
    Verify that the WinCC flexible Runtime simulation component is installed. Check that no conflicting software is blocking the simulation process.
    Event ID: 1005
    Inconsistent project data detected after migration from an older WinCC flexible version
    Use the built-in project migration wizard to resolve inconsistencies. Back up the original project before performing migration.
    Event ID: 1006
    Alarm logging configuration error — alarm buffer overflow setting invalid
    Review the alarm logging settings and ensure the buffer size and overflow behavior are correctly defined within supported limits.

    Frequently Asked Questions

    Which HMI panels are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Compatibility depends on the specific panel firmware version.

    Is WinCC flexible 2007 compatible with SIMATIC STEP 7?

    Yes, WinCC flexible 2007 integrates with SIMATIC STEP 7, allowing shared symbol tables and coordinated project management within the same engineering environment.

    What communication protocols does WinCC flexible 2007 support?

    The software supports PROFIBUS, PROFINET, MPI, and Industrial Ethernet communication protocols, enabling connectivity to a wide range of Siemens and third-party controllers.

    Can WinCC flexible 2007 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible projects to be imported and converted, though some manual rework may be required depending on project complexity.

    What operating systems are compatible with WinCC flexible 2007?

    WinCC flexible 2007 is compatible with Windows XP and Windows Vista at release, with support extended to Windows 7 (32-bit) via service pack updates. 64-bit operating systems are not natively supported.

    Troubleshooting

    Software fails to start after installation and displays a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2007 is present and correctly assigned to the local machine.

    Transfer or reinstall the license using the ALM tool. Ensure the license dongle (if applicable) is connected, or that the software-based license is properly activated on the engineering PC.

    Project transfer to HMI panel fails repeatedly

    Check the transfer channel configuration in WinCC flexible and verify the physical connection. Confirm the HMI panel is set to transfer mode and that the IP address or MPI address matches the project settings.

    Correct the communication parameters in the project transfer settings. Disable any PC firewall rules blocking the transfer port, and ensure the correct cable or network adapter is selected.

    Compilation errors appear when building the HMI project

    Review the output window for specific error messages referencing tag names, screen objects, or script functions. Identify duplicate tag addresses or unsupported object configurations.

    Correct the flagged errors in the tag table or screen editor. Remove duplicate entries, fix invalid data type assignments, and recompile the project after each correction.

    WinCC flexible 2007 crashes or becomes unresponsive during project editing

    Check the engineering PC for sufficient RAM and disk space. Review the Windows Event Viewer for application crash logs referencing WinCC flexible processes.

    Ensure the PC meets the minimum system requirements. Install all available Siemens service packs and hotfixes for WinCC flexible 2007. Save projects frequently and consider splitting large projects into smaller modules.

    Simulated project on PC does not reflect actual panel behavior

    Verify that the simulation is using the correct controller driver and that all tag connections are properly configured for simulation mode.

    Switch to the appropriate simulation driver in the project settings. Ensure all tags used in simulation have valid default values assigned, and that no external PLC connection is required for the simulated screens.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart