Siemens 6AV6372-1DC08-0AX3 WinCC flexible 2008
€ 227,32
The Siemens 6AV6372-1DC08-0AX3 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing human-machine interface (HMI) applications used with Siemens SIMATIC HMI panels. It belongs to the SIMATIC WinCC flexible product line, which serves as the predecessor to the current WinCC TIA Portal environment.
WinCC flexible 2008 offers a comprehensive set of engineering tools for configuring screens, alarms, tags, scripts, and communication connections for a wide range of Siemens HMI devices. The software supports multiple communication protocols including PROFIBUS, PROFINET, MPI, and Ethernet, enabling integration with SIMATIC S7-200, S7-300, S7-400, and other compatible controllers. It includes features such as faceplates, trend displays, recipe management, user administration, and multi-language project support. The 2008 edition introduced improved performance, expanded device support, and enhanced scripting capabilities compared to earlier versions.
WinCC flexible 2008 is used across a broad range of industrial sectors including manufacturing, automotive, food and beverage, water treatment, and process industries. It is the standard engineering tool for configuring Siemens SIMATIC HMI panels such as the TP, OP, MP, and Mobile Panel series. Its scalability allows engineers to develop projects ranging from simple operator panels to complex multi-panel visualization systems.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Single-user engineering license |
| Compatible HMI Devices | SIMATIC HMI TP, OP, MP, Mobile Panel series |
| Compatible Controllers | SIMATIC S7-200, S7-300, S7-400, WinAC |
| Communication Interfaces | PROFIBUS, PROFINET, MPI, Ethernet, USB |
| Operating System | Windows XP (SP2 or higher), Windows Vista, Windows 7 |
| Language Support | Multi-language project configuration |
| Series/Product Family | SIMATIC WinCC flexible |
| Bus System Compatibility | PROFIBUS DP, PROFINET IO, MPI |
| Certifications | CE |
| Project Features | Alarms, recipes, trends, scripts, user administration, faceplates |
| Media | DVD with license key |
Common Error Codes & System Events
- Event ID: 1000
- Application error during WinCC flexible startup, typically caused by corrupted installation files or missing runtime components.
Repair or reinstall the WinCC flexible 2008 software. Ensure all required Microsoft redistributable packages are installed. - Event ID: 1001
- License not found or license key invalid. The software cannot verify a valid license for the installed edition.
Check that the license dongle or software license key is correctly installed using the Siemens Automation License Manager (ALM). Transfer or reactivate the license as required. - Event ID: 2001
- Communication error between the engineering station and the HMI panel during project download.
Verify the communication cable and interface settings. Confirm the correct communication driver is selected and the HMI panel IP address or MPI address is correctly configured. - Event ID: 3010
- Project compilation error due to inconsistent tag or screen configuration.
Review the compiler output log for specific inconsistencies. Correct invalid tag references, missing screen objects, or unsupported functions for the target HMI device. - Event ID: 4000
- Runtime simulation failure. The integrated simulator cannot start due to missing components or incompatible project settings.
Ensure the WinCC flexible runtime simulation component is installed. Check that the project is configured for a device type that supports simulation. - Event ID: 5001
- Database error during project save or open, often caused by file corruption or insufficient disk permissions.
Check disk space and file system permissions on the project directory. Restore from a backup copy of the project file if corruption is confirmed. - Event ID: 6000
- Version conflict detected. The project was created with a newer or incompatible version of WinCC flexible.
Upgrade the WinCC flexible installation to the required version or use the migration tool to convert the project to a compatible format.
Frequently Asked Questions
Which Siemens HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Specific supported devices include panels from the 170, 270, 370, and 570 series as well as the MP 277 and MP 377.
Is WinCC flexible 2008 compatible with Windows 10?
WinCC flexible 2008 was designed for Windows XP, Vista, and Windows 7 and is not officially supported on Windows 10. Running it on Windows 10 may cause installation or runtime issues, and Siemens recommends migrating to WinCC in TIA Portal for use on modern operating systems.
Can projects created in WinCC flexible 2008 be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. Some manual rework may be required after migration due to differences in functionality and supported device types.
What communication protocols does WinCC flexible 2008 support?
WinCC flexible 2008 supports PROFIBUS DP, PROFINET IO, MPI, TCP/IP Ethernet, and several third-party protocols via optional communication drivers. This allows connectivity to a wide range of Siemens and non-Siemens controllers.
Does the 6AV6372-1DC08-0AX3 license include runtime software for the HMI panel?
The engineering software license covers project creation and download capabilities on the PC. Runtime software for the HMI panel itself is typically pre-installed on the panel hardware and does not require a separate PC-side runtime license for standard panel operation.
Troubleshooting
WinCC flexible 2008 fails to install or crashes during installation
Check the Windows event log for installation errors. Verify that the operating system version is supported (Windows XP SP2, Vista, or Windows 7) and that all prerequisite software such as Microsoft .NET Framework and Visual C++ redistributables are present.
Install all required prerequisites before running the WinCC flexible setup. Run the installer as Administrator and disable antivirus software temporarily during installation. If errors persist, use the Siemens Support installer log to identify the failing component.
License error displayed on startup — software runs in demo mode
Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2008 is listed and assigned to the local machine. Verify that the license dongle is connected if a hardware key is used.
Transfer the license to the engineering PC using the ALM tool. If using a software license, ensure it has not been moved or deleted. Contact Siemens support for license recovery if the license was lost due to a hard drive failure.
Project download to HMI panel fails with communication error
Verify the physical connection between the PC and the HMI panel (Ethernet, USB, or PROFIBUS cable). Check that the correct communication channel is selected in the project transfer settings and that the panel is in transfer mode.
Set the HMI panel to transfer mode manually via the panel's start center. Confirm IP address or MPI address settings match the project configuration. Replace the communication cable if a hardware fault is suspected.
Compiled project reports errors for unsupported functions on target device
Review the compiler output window for specific error messages referencing unsupported objects or functions. Compare the functions used in the project against the feature set supported by the selected target HMI device type.
Change the target device in the project settings to match the actual HMI hardware, or replace unsupported objects with compatible alternatives. Consult the WinCC flexible 2008 device compatibility list in the Siemens documentation.
WinCC flexible 2008 does not recognize or display the connected HMI panel in the device list
Check that the correct PC interface adapter (e.g., PC Adapter USB for MPI/PROFIBUS or standard NIC for Ethernet) is installed and configured. Verify that the interface settings in WinCC flexible match the physical connection type.
Install or update the PC interface adapter drivers. Configure the correct interface in the WinCC flexible communication settings. For Ethernet connections, ensure both the PC and HMI panel are on the same subnet.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page