• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-2BS08-0AJ0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6371-2BS08-0AJ0 SIMATIC WinCC

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6371-2BS08-0AJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-2BS08-0AJ0 is a software license package belonging to the SIMATIC WinCC (Windows Control Center) family, developed by Siemens for PC-based SCADA and HMI visualization. This part number corresponds to a WinCC Runtime or configuration software edition, designed to run on standard industrial PCs and operator stations within automation environments. It serves as the central visualization and supervisory control layer in Siemens-based automation architectures.

    WinCC provides a comprehensive set of features including process visualization, alarm management, trend logging, recipe management, and reporting functions. It supports a wide range of communication interfaces including PROFIBUS, PROFINET, MPI, and OPC/OPC UA, enabling seamless integration with SIMATIC S7 PLCs and third-party controllers. The software offers scalable tag counts, redundancy options, and multi-client/server architectures, making it suitable for both small standalone installations and large distributed control systems.

    The 6AV6371-2BS08-0AJ0 is typically deployed in industries such as manufacturing, process automation, water and wastewater treatment, energy management, and building automation. It is used on operator workstations, control room PCs, and industrial panel PCs where centralized monitoring and control of plant processes is required. Its compatibility with the broader Siemens TIA Portal and SIMATIC ecosystem makes it a standard choice for Siemens-based plant automation projects.

    Technical Specifications

    Product Family SIMATIC WinCC
    Software Type SCADA / HMI Visualization Software
    Platform PC-based (Windows OS)
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC, OPC UA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500
    Architecture Support Single-station, Client/Server, Multi-client
    Redundancy Supported (server redundancy option)
    Certifications CE
    License Type Floating / Workstation License
    Operating System Microsoft Windows (industrial versions)

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC Runtime startup error — the runtime application failed to initialize correctly.
    Check Windows Event Viewer for underlying OS errors. Verify that all WinCC components are correctly installed and that the license key is present and valid.
    Event ID: 1001
    Tag communication error — one or more process tags cannot be read from the connected PLC.
    Verify the communication channel configuration, check network connectivity to the PLC, and confirm that the PLC program is running and the data blocks are accessible.
    Event ID: 2501
    License not found or license expired — WinCC Runtime cannot start due to a missing or invalid software license.
    Insert the correct SIMATIC software license key (USB dongle or software license), or transfer the license using the Automation License Manager (ALM).
    Event ID: 10000
    Alarm logging system error — the alarm archive database could not be accessed or written to.
    Check available disk space on the archive drive, verify SQL Server service is running, and ensure the WinCC project database is not corrupted.
    Event ID: 3000
    Redundancy switchover event — the active WinCC server has failed and the standby server has taken over.
    Investigate the cause of the primary server failure, restore the primary server to operational state, and perform a manual switchover back once the issue is resolved.
    Event ID: 112
    Project open error — WinCC could not open the specified project file.
    Verify the project path is correct and accessible, check file permissions, and ensure no other WinCC instance has the project locked open.
    Event ID: 4
    Database connection failure — WinCC cannot connect to the internal Microsoft SQL Server database.
    Restart the SQL Server (WINCC) service via Windows Services, check that the SQL Server instance is properly installed, and verify that the WinCC project database files are intact.

    Frequently Asked Questions

    What is the tag count or power tag limit for the 6AV6371-2BS08-0AJ0 license?

    The exact tag count depends on the specific WinCC edition encoded in this part number. WinCC licenses are available in various power tag tiers (e.g., 128, 512, 2048, 65536 tags). Refer to the Siemens SIMATIC WinCC ordering data or the license documentation included with this part number to confirm the exact tag limit.

    Is this WinCC software compatible with TIA Portal?

    WinCC Runtime Professional is integrated within the TIA Portal engineering framework. Depending on the specific edition of this license, it may be used standalone or in conjunction with TIA Portal V13 and later versions.

    What operating system is required to run this WinCC software?

    SIMATIC WinCC requires a supported Microsoft Windows operating system, typically Windows 7 Professional/Ultimate (64-bit) or Windows 10 (64-bit) for more recent versions. The specific OS requirements depend on the WinCC version included in this package.

    Does this license support OPC UA communication?

    Yes, SIMATIC WinCC supports OPC UA as a communication interface, allowing data exchange with third-party systems and controllers that are OPC UA compliant.

    Can WinCC be used with non-Siemens PLCs?

    Yes, WinCC supports OPC and OPC UA standards, which allow communication with PLCs and controllers from other manufacturers. Direct channel drivers are primarily optimized for SIMATIC S7 controllers.

    Troubleshooting

    WinCC Runtime fails to start and displays a license error

    Open the Siemens Automation License Manager (ALM) to check whether a valid WinCC license is installed or transferred to the PC. Verify the USB license dongle is connected if a hardware key is used.

    Transfer or install the correct WinCC Runtime license using the Automation License Manager. If using a USB dongle, ensure it is recognized by the OS and the ALM software. Contact Siemens license support if the license appears corrupted.

    Process tags show invalid or no values in WinCC Runtime

    Check the communication channel status in WinCC Channel Diagnostics. Verify the PLC IP address or PROFIBUS address is correctly configured and that the PLC is in RUN mode and reachable on the network.

    Correct the channel configuration in WinCC, restore network connectivity to the PLC, and restart the WinCC channel driver. Ensure firewall rules are not blocking SIMATIC communication ports.

    WinCC project cannot be opened and returns a database error

    Attempt to open the project and note the exact error message. Check whether the Microsoft SQL Server (WINCC) service is running in Windows Services. Verify the project folder is not read-only or corrupted.

    Start the SQL Server (WINCC) service if it is stopped. If the database is corrupted, use the WinCC project duplicator or backup to restore a clean copy. Run the WinCC consistency check tool to identify and repair project errors.

    Alarm logging stops recording new alarms in WinCC

    Check available disk space on the drive where the WinCC archive is stored. Verify that the SQL Server service is running and that the alarm logging configuration in WinCC is active and not paused.

    Free up disk space on the archive drive, restart the SQL Server service if necessary, and verify the alarm logging settings in the WinCC project. Adjust archive size limits or enable automatic archiving to prevent future overflow.

    WinCC client cannot connect to the WinCC server in a client/server setup

    Verify network connectivity between the client and server PCs. Check that the WinCC server project is running in Runtime mode and that the client is configured with the correct server name and project path.

    Correct the server name and project path in the WinCC client configuration. Ensure Windows Firewall on the server allows WinCC communication ports. Verify that both client and server are on the same Windows domain or workgroup with appropriate user permissions.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart