• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-2BP08-0AX0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6371-2BP08-0AX0 SIMATIC WinCC

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6371-2BP08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-2BP08-0AX0 is a software license package for SIMATIC WinCC (Windows Control Center), Siemens' professional SCADA and HMI runtime software platform. This part number corresponds to a WinCC Runtime license, enabling operator control and monitoring of industrial processes on standard PC-based hardware. It belongs to the SIMATIC WinCC V7 product family and is designed for use within Siemens' TIA (Totally Integrated Automation) ecosystem.

    WinCC Runtime provides a powerful process visualization environment supporting tag-based licensing, with this variant supporting up to 8192 process tags (PowerTags). The software offers comprehensive alarming, trending, reporting, and scripting capabilities using VBScript and ANSI-C. It supports OPC DA/UA client and server functionality, enabling integration with third-party systems. Communication with Siemens PLCs is achieved via SIMATIC NET drivers, supporting PROFIBUS, PROFINET, MPI, and Industrial Ethernet protocols. The platform runs on Windows operating systems and supports redundant server configurations for high-availability applications.

    SIMATIC WinCC Runtime is widely deployed in process industries including chemical, pharmaceutical, oil and gas, water treatment, and power generation, as well as in discrete manufacturing and building automation. Its scalable tag-based licensing model makes it suitable for medium to large-scale SCADA installations requiring centralized monitoring and control across multiple production lines or plant areas. The software's open architecture and extensive driver library allow integration into heterogeneous automation environments.

    Technical Specifications

    Software Type SCADA / HMI Runtime Software
    Product Family SIMATIC WinCC V7
    PowerTags (Process Tags) 8192
    Communication Protocols PROFIBUS, PROFINET, MPI, Industrial Ethernet, OPC DA, OPC UA
    Scripting Support VBScript, ANSI-C
    Operating System Windows (32/64-bit, compatible versions per WinCC V7 requirements)
    Redundancy Support Yes (Server redundancy configurable)
    OPC Support OPC DA Client/Server, OPC UA Client/Server
    License Type Single-user runtime license
    Certifications CE
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500
    Trending & Reporting Integrated trend display and report designer
    Alarm Management Integrated alarm logging and archiving

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC Runtime startup failure — the runtime process could not be initialized, often due to licensing issues or corrupted project data.
    Verify the WinCC license is correctly installed using the Siemens Automation License Manager. Check project integrity and restart the WinCC runtime.
    Event ID: 112
    Tag connection error — one or more process tags cannot be read from the connected PLC or data source.
    Check the communication channel configuration, verify PLC is online and reachable, and confirm the correct driver is installed and configured.
    Event ID: 10241
    Archive database error — the WinCC tag or alarm archive database is unavailable or corrupted.
    Check the Microsoft SQL Server service is running. Run the WinCC database consistency check tool and restore from backup if necessary.
    Event ID: 1008
    License not found or invalid — WinCC Runtime cannot find a valid license for the configured number of PowerTags.
    Open the Siemens Automation License Manager, verify the correct license (8192 tags) is present and not expired or transferred. Reactivate or transfer the license as needed.
    Event ID: 10001
    Communication driver load failure — the specified SIMATIC NET or channel driver failed to load during runtime startup.
    Reinstall the SIMATIC NET communication software, verify driver compatibility with the installed WinCC version, and check Windows Event Viewer for additional details.
    Event ID: 2
    Project open error — WinCC Runtime cannot open the specified project, possibly due to incorrect path, access permissions, or version mismatch.
    Verify the project path is correct and accessible, ensure the WinCC project version matches the installed runtime version, and check Windows user account permissions.
    Event ID: 10048
    Redundancy switchover event — the active WinCC server has failed and the standby server has taken over operation.
    Investigate the cause of the primary server failure, check network connectivity and hardware health, and restore the primary server before performing a manual switchback.

    Frequently Asked Questions

    How many process tags (PowerTags) does the 6AV6371-2BP08-0AX0 license support?

    This license supports up to 8192 PowerTags (process tags), making it suitable for medium to large-scale SCADA installations.

    Is this WinCC Runtime license compatible with SIMATIC S7-1500 PLCs?

    Yes, WinCC V7 Runtime supports communication with SIMATIC S7-1500, S7-400, S7-300, and S7-1200 PLCs via SIMATIC NET drivers over PROFINET or Industrial Ethernet.

    Can WinCC Runtime configured with this license operate in a redundant server setup?

    Yes, WinCC V7 supports server redundancy configurations. A separate WinCC Redundancy option package is required in addition to the runtime license.

    What operating systems are supported by SIMATIC WinCC V7 Runtime?

    WinCC V7 Runtime is supported on Windows 7 (64-bit), Windows 10 (64-bit), and Windows Server 2012/2016 R2, depending on the specific WinCC V7 service pack version installed.

    Does this license include OPC UA server functionality?

    Yes, WinCC V7 Runtime includes OPC DA and OPC UA client and server functionality, allowing integration with third-party SCADA systems and devices that support these standards.

    Troubleshooting

    WinCC Runtime fails to start and displays a licensing error

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC Runtime license for 8192 tags is present, active, and not expired or moved to another machine.

    Transfer or reactivate the correct license using the ALM tool. Ensure the license dongle (if used) is connected, or reactivate the software license on the correct hardware fingerprint.

    Process tags show invalid or no values during runtime

    Check the channel diagnostics in WinCC for communication errors. Verify the PLC is online, the IP address or MPI address is correctly configured, and the SIMATIC NET driver is running.

    Correct the communication channel settings in WinCC Configuration Studio, restart the channel driver, and confirm network connectivity to the PLC using a ping test or SIMATIC NET diagnostic tools.

    WinCC archive database becomes unavailable or reports SQL errors

    Check the Windows Services panel to confirm that the Microsoft SQL Server (WinCC instance) service is running. Review the SQL Server error log and WinCC diagnostic log for specific database errors.

    Restart the SQL Server service if stopped. Run the WinCC project consistency check. If the database is corrupted, restore from the most recent backup or use the WinCC database repair utility.

    WinCC Runtime project opens but screens do not display correctly or appear blank

    Check for missing or incompatible graphic objects, ActiveX controls, or scripts. Review the WinCC error log for object load failures or script runtime errors.

    Reinstall any missing ActiveX controls or WinCC add-ons. Review and correct VBScript or C-script errors in the script editor. Ensure the display resolution and color depth settings match the project configuration.

    Redundancy switchover does not occur when the primary server fails

    Verify that the WinCC Redundancy package is correctly installed and configured on both servers. Check network connectivity between the primary and standby servers on the redundancy synchronization network.

    Reconfigure the redundancy settings in WinCC, ensuring both servers have matching project versions and the synchronization network interface is correctly assigned. Test failover manually using the WinCC redundancy test function.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart