• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-2BP07-5AJ0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6371-2BP07-5AJ0 SIMATIC WinCC

    € 1.188,00

    Reset
    Clear
    SKU: 6AV6371-2BP07-5AJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-2BP07-5AJ0 is a WinCC (Windows Control Center) SCADA/HMI software package belonging to the SIMATIC HMI product family from Siemens. This part number corresponds to a WinCC runtime or configuration license, designed to provide supervisory control and data acquisition capabilities for industrial process visualization on PC-based platforms. It is part of Siemens' established SIMATIC WinCC V7 software line, enabling operators and engineers to monitor and control industrial processes through a PC-based HMI environment.

    WinCC 6AV6371-2BP07-5AJ0 offers a comprehensive set of features including tag-based licensing for scalable deployments, support for OPC DA/UA communication standards, and integration with SIMATIC S7 PLCs via PROFIBUS and PROFINET interfaces. The software includes a powerful scripting environment (VBScript and C-Script), an alarm management system, trend displays, and historical data logging. It supports redundant server configurations for high-availability applications and provides a multi-user client-server architecture for distributed HMI deployments.

    This WinCC software package is widely used in process industries such as water and wastewater treatment, oil and gas, chemical processing, and power generation, as well as in discrete manufacturing environments including automotive assembly and food and beverage production. Its compatibility with the broader Siemens TIA Portal ecosystem and SIMATIC hardware makes it a suitable choice for facilities already operating Siemens automation infrastructure. The scalable licensing model allows deployment from small single-station installations up to large distributed SCADA systems.

    Technical Specifications

    Software Family SIMATIC WinCC V7
    Software Type SCADA / PC-based HMI Runtime & Configuration
    License Type Floating/Powerpack license (tag-based)
    Communication Interfaces PROFIBUS, PROFINET, OPC DA, OPC UA, Ethernet
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500
    Scripting Support VBScript, ANSI-C Script
    Redundancy Support Yes, server redundancy supported
    Architecture Client-server, multi-user
    Operating System Windows Server / Windows 10 (64-bit)
    Historical Data Logging Yes, integrated process historian
    Alarm Management Yes, integrated alarm server
    OPC Support OPC DA, OPC UA (client and server)
    Certifications CE, UL
    Series/Product Family SIMATIC WinCC

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC Runtime startup failure. The runtime process could not be initialized correctly.
    Check Windows Event Viewer for underlying application errors. Verify that all WinCC services are running and that the license dongle or software license is correctly installed.
    Event ID: 1001000
    Tag communication error. One or more configured tags cannot be read from the connected PLC or data source.
    Verify the communication channel configuration, check PLC connection status, and confirm that the correct driver is installed and active in WinCC Explorer.
    Event ID: 1002000
    License not found or invalid. WinCC cannot find a valid license for the configured number of tags or features.
    Insert the correct USB license dongle or verify the software license using Siemens Automation License Manager (ALM). Ensure the license matches the configured tag count.
    Event ID: 1003000
    Database connection error. WinCC cannot connect to the internal Microsoft SQL Server database.
    Check that the SQL Server instance (WINCC) is running in Windows Services. Restart the SQL Server service and then restart WinCC Runtime.
    Event ID: 1004000
    Redundancy switchover event. The active WinCC server has failed and the standby server has taken over.
    Investigate the cause of the primary server failure. Check network connectivity, hardware health, and WinCC server logs before attempting to restore the primary server.
    Event ID: 1005000
    Archive backup failure. The process historian could not complete a scheduled data archive backup.
    Check available disk space on the archive target drive. Verify backup path permissions and ensure the WinCC archive service is running without errors.
    Event ID: 1006000
    OPC server connection lost. The WinCC OPC client channel has lost communication with the configured OPC server.
    Verify that the OPC server application is running on the target machine. Check network connectivity and firewall settings for DCOM/OPC communication ports.
    Event ID: 1007000
    User administration error. A user login attempt failed due to incorrect credentials or an expired account.
    Verify user credentials in WinCC User Administrator. Reset the password or re-enable the account if it has been locked due to repeated failed login attempts.

    Frequently Asked Questions

    What is the tag capacity of the 6AV6371-2BP07-5AJ0 WinCC license?

    The exact tag count for this specific license variant should be verified against the Siemens SIMATIC WinCC ordering data, as WinCC licenses are available in multiple tag tiers (e.g., 128, 512, 2048, 65536 tags). The part number suffix encodes the specific licensed tag count and feature set.

    Is this WinCC license compatible with TIA Portal?

    WinCC V7 (the product line this license belongs to) is a standalone SCADA platform and is distinct from WinCC Advanced/Professional used within TIA Portal. It can exchange data with TIA Portal-based PLCs via OPC or SIMATIC drivers, but it is not a TIA Portal-integrated product.

    What operating systems are supported by this WinCC software?

    SIMATIC WinCC V7 supports 64-bit versions of Windows 10 and Windows Server 2016/2019. Installation on unsupported operating systems is not recommended and may result in compatibility issues.

    Does this WinCC package support redundant server configurations?

    Yes, WinCC V7 supports a redundant server architecture where a standby server automatically takes over if the primary server fails, ensuring high availability for critical process monitoring applications.

    What communication drivers are included with WinCC V7?

    WinCC V7 includes a comprehensive set of communication drivers supporting SIMATIC S7 PLCs via PROFIBUS and PROFINET, as well as OPC DA/UA, Modbus TCP, and various third-party PLC drivers depending on the installed channel packages.

    Troubleshooting

    WinCC Runtime fails to start and displays a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC license is detected. Verify that the USB dongle is inserted or that a software license is properly transferred to the machine.

    Insert the correct USB license dongle or use ALM to transfer a valid software license to the local machine. Ensure the license tag count matches or exceeds the number of tags configured in the WinCC project.

    Tags show no value or display '#COM' error in Runtime

    Check the WinCC channel diagnostics in WinCC Explorer under the communication driver. Verify the PLC IP address or PROFIBUS address, and confirm the PLC is in RUN mode and reachable from the WinCC server.

    Correct the communication channel configuration (IP address, rack/slot settings). Restart the WinCC channel driver and verify network connectivity using ping or SIMATIC NET diagnostics tools.

    WinCC cannot connect to the SQL Server database on startup

    Open Windows Services and check whether the SQL Server (WINCC) instance is in a 'Running' state. Review the Windows Event Viewer Application log for SQL Server error messages.

    Start the SQL Server (WINCC) service manually if it has stopped. If the database is corrupt, use the WinCC database repair tools or restore from a recent backup. Ensure sufficient disk space is available for database operations.

    Historical trend data is missing or incomplete in WinCC

    Check the WinCC Tag Logging configuration to confirm that the relevant tags have archiving enabled. Verify that the archive server service is running and that the storage path has sufficient free disk space.

    Re-enable archiving for the affected tags if it was accidentally disabled. Free up disk space on the archive drive and restart the WinCC Archive service. Check the WinCC diagnostic log for any archive overflow events.

    WinCC client cannot connect to the WinCC server in a multi-user setup

    Verify network connectivity between the client and server machines. Check Windows Firewall settings on the server for blocked WinCC ports. Confirm that the WinCC server project is active and that the client is correctly configured with the server computer name.

    Add WinCC application exceptions to the Windows Firewall on the server. Ensure the client's WinCC installation matches the server version. Re-configure the client connection in WinCC Explorer using the correct server hostname or IP address.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart