
Siemens 6AV6371-2BM08-0AX0 WinCC flexible 2008
€ 799,44
The Siemens 6AV6371-2BM08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for a wide range of operator panels.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It provides a library of pre-built faceplates, multilingual project support, and integration with STEP 7 for seamless project data exchange. The platform supports scalable runtime licensing for various panel sizes and PC-based HMI configurations.
WinCC flexible 2008 is widely deployed in manufacturing, process automation, food and beverage, automotive, and water treatment industries. It is used to engineer operator interfaces for machinery, production lines, and process plants where SIMATIC HMI panels such as the TP, OP, MP, and Mobile Panel series are installed. Its compatibility with the broader SIMATIC automation ecosystem makes it a standard choice for system integrators and OEMs building Siemens-based control architectures.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Series/Product Family | SIMATIC WinCC flexible |
| License Type | Engineering software license |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet |
| Compatible Panel Families | SIMATIC TP, OP, MP, Mobile Panel series |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Integration | STEP 7 project integration supported |
| Language Support | Multilingual project engineering |
| Alarm Management | Integrated alarm logging and display |
| Recipe Management | Supported |
| Trend Display | Supported |
| Scripting | VB Script support for automation tasks |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000001
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target device.
Check that the correct runtime version is installed on the panel. Verify license availability and re-transfer the project using the Transfer function in WinCC flexible. - Event ID: 1000002
- Communication error — No connection established between HMI and PLC.
Verify network cable connections and check PLC address settings. Confirm that the communication driver and PLC address configured in the project match the physical setup. - Event ID: 1000003
- Tag read/write error — A configured tag could not be read from or written to the PLC.
Check that the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Verify PLC program is running. - Event ID: 1000004
- License not found — No valid WinCC flexible engineering or runtime license detected.
Insert the license dongle or activate the software license using the Automation License Manager. Ensure the correct license type is installed for the project size. - Event ID: 1000005
- Project transfer error — Project could not be transferred to the target HMI panel.
Check the transfer cable or Ethernet connection. Ensure the panel is in Transfer mode and that the correct target device IP address or COM port is configured in the transfer settings. - Event ID: 1000006
- Alarm buffer overflow — The alarm buffer on the HMI has reached its maximum capacity.
Archive or clear existing alarms. Review alarm configuration to reduce unnecessary alarm triggers and increase buffer size if supported by the panel. - Event ID: 1000007
- Recipe data error — Recipe records could not be read or written correctly.
Verify recipe configuration in the project, check that the associated PLC tags are correctly mapped, and ensure sufficient memory is available on the panel for recipe storage.
Frequently Asked Questions
Which SIMATIC HMI panels are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP, OP, MP, and Mobile Panel series. It also supports PC-based runtime environments running on compatible Windows operating systems.
Does WinCC flexible 2008 integrate with STEP 7?
Yes, WinCC flexible 2008 can be integrated directly into STEP 7 projects, allowing shared tag databases and simplified project management within the SIMATIC engineering environment.
What communication protocols does WinCC flexible 2008 support?
The software supports MPI, PROFIBUS DP, and Industrial Ethernet for communication with SIMATIC PLCs. Additional drivers may be available for third-party controller connectivity.
Is a hardware dongle required to run WinCC flexible 2008?
A valid license managed through the Siemens Automation License Manager is required. Depending on the license variant, this may be tied to a USB dongle or a software-based activation.
Can WinCC flexible 2008 projects be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible 2008 projects to be imported and converted, though some manual rework may be required depending on project complexity.
Troubleshooting
HMI panel displays 'No connection to PLC' after project transfer
Check the communication settings in the WinCC flexible project, including PLC address, subnet, and protocol selection. Verify physical cable connections and PLC operating state.
Correct the PLC address and communication parameters in the project, re-transfer to the panel, and confirm the PLC is in RUN mode with the correct network configuration.
WinCC flexible Runtime does not start on the panel after transfer
Check that the runtime version installed on the panel matches the version used during project engineering. Verify that the license is valid and detected by the Automation License Manager.
Update the panel firmware to match the engineering software version, or re-engineer the project using the correct software version. Re-activate the license if it is not detected.
Tags show invalid or dashes on the HMI screen during operation
This typically indicates a communication fault or incorrect tag addressing. Check the tag table in WinCC flexible and compare addresses against the PLC program.
Correct any mismatched tag addresses in the project, ensure the PLC data blocks are not optimized if using absolute addressing, and re-transfer the project.
Project transfer fails with a connection timeout error
Verify that the panel is set to Transfer mode and that the PC and panel are on the same network subnet. Check firewall settings on the engineering PC.
Disable Windows Firewall temporarily during transfer, confirm the panel IP address matches the transfer settings in WinCC flexible, and retry the transfer operation.
Alarms are not displayed on the HMI even though PLC fault bits are set
Check the alarm configuration in WinCC flexible, including the trigger tag, trigger bit, and alarm class settings. Verify that the alarm view or alarm window object is correctly placed on the screen.
Correct the alarm trigger tag and bit address in the alarm editor, ensure the alarm class is active and visible, and confirm the alarm display object is configured on the relevant HMI screen.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page


