
Siemens 6AV6371-1HV48-0AX0 WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6371-1HV48-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the broader SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across a wide range of automation tasks.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and scripting capabilities via VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 controllers via MPI, PROFIBUS DP, and Industrial Ethernet (PROFINET). It provides multi-language project support, library management, and faceplates for reusable graphical objects. The 2008 version introduced enhanced performance, improved usability, and extended device support compared to earlier releases.
WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is suitable for configuring operator panels such as the SIMATIC TP, OP, MP, and Mobile Panel series. Industries including automotive, food and beverage, chemical processing, and packaging rely on this software to develop operator interfaces that monitor and control production processes efficiently.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Software Type | Engineering Software / HMI Configuration Tool |
| Compatible Controllers | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (PROFINET) |
| Scripting Support | VBScript |
| Language Support | Multi-language project support |
| Compatible Panels | SIMATIC TP, OP, MP, Mobile Panel series |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Series/Product Family | WinCC flexible |
| License Type | Single-user software license |
| Certifications | CE |
Common Error Codes and System Events
- Event ID: 1000
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target device.
Check that the correct Runtime version is installed on the panel. Verify project compatibility with the target device type and Runtime version. Reinstall Runtime if necessary. - Event ID: 2501
- Communication error — Connection to the configured PLC controller could not be established.
Verify network or bus cabling between the HMI panel and the PLC. Check MPI/PROFIBUS address settings or Ethernet IP configuration. Confirm the PLC is powered and in RUN mode. - Event ID: 3010
- Tag read/write error — A configured tag could not be read from or written to the controller.
Check that the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Verify data type consistency between HMI tag and PLC variable. - Event ID: 4000
- License error — No valid license found for WinCC flexible Engineering or Runtime.
Verify that the license dongle (USB or software license) is properly installed. Use Siemens Automation License Manager (ALM) to check license status and transfer or repair the license if required. - Event ID: 5100
- Project transfer error — Download of the project to the target panel failed.
Check the transfer connection (USB, Ethernet, or MPI). Ensure the panel is in Transfer mode. Verify that the project is compiled without errors before attempting transfer. - Event ID: 6200
- Recipe data error — Recipe records could not be read or written correctly.
Check recipe configuration in the project for correct tag assignments and data types. Verify available memory on the target device for recipe storage. - Event ID: 7300
- Alarm logging error — Alarm buffer overflow or alarm log file could not be written.
Reduce the number of active alarms or increase the alarm buffer size in the project settings. Check available storage space on the target device. - Event ID: 8001
- Screen navigation error — A configured screen change could not be executed.
Verify that the target screen referenced in the navigation event exists in the project. Recompile and retransfer the project to the panel.
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP, OP, MP, and Mobile Panel series. It also supports PC-based Runtime installations on compatible Windows operating systems.
Is WinCC flexible 2008 compatible with TIA Portal projects?
WinCC flexible 2008 is not natively compatible with TIA Portal. However, Siemens provides a migration tool within TIA Portal to import WinCC flexible projects for conversion to WinCC (TIA Portal) format.
What communication protocols does WinCC flexible 2008 support?
The software supports MPI, PROFIBUS DP, and Industrial Ethernet (PROFINET) for communication with SIMATIC S7 controllers, as well as OPC and other third-party driver connections.
What operating systems are supported for the engineering station?
WinCC flexible 2008 is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7 (32-bit). It is not supported on 64-bit operating systems without compatibility measures.
Can WinCC flexible 2008 be used to configure multi-language HMI projects?
Yes, WinCC flexible 2008 includes multi-language project support, allowing operators to switch display languages at runtime. Languages are configured within the engineering environment and downloaded as part of the project.
Troubleshooting
WinCC flexible 2008 fails to install or crashes during installation
Check Windows version compatibility. Verify that .NET Framework and other prerequisites listed in the installation guide are present. Review the installation log file for specific error messages.
Install all required prerequisites including the correct .NET Framework version. Disable antivirus software temporarily during installation. Run the installer as Administrator and ensure no conflicting Siemens software versions are present.
Project cannot be transferred to the HMI panel
Confirm the panel is set to Transfer mode. Check the physical connection (USB, Ethernet cable, or MPI adapter). Verify the transfer settings in WinCC flexible match the panel's configured interface.
Set the panel to Transfer mode via the Start Center or Control Panel on the device. Ensure the correct communication interface and parameters are configured in the Transfer settings dialog within WinCC flexible. Recompile the project before retransferring.
Runtime on the panel shows communication errors or tags display hash marks (###)
Hash marks indicate that the HMI cannot read the tag value from the PLC. Check the PLC connection status in the Runtime diagnostics. Verify PLC is running and the network connection is active.
Check all bus or Ethernet cabling between the panel and PLC. Verify that the PLC address, subnet, and communication parameters in the WinCC flexible project match the actual PLC configuration. Confirm the PLC program is running and the relevant data areas are accessible.
Automation License Manager reports missing or invalid license for WinCC flexible
Open Siemens Automation License Manager (ALM) and check the license status. Determine whether the license is stored on a USB dongle or as a software license on the hard drive.
If using a USB dongle, ensure it is properly connected and recognized by the PC. For software licenses, use ALM to repair or reactivate the license. If the license has been lost due to a hard drive failure, contact Siemens for license recovery procedures.
Compiled project generates errors or warnings related to unsupported functions
Review the compiler output log for specific error messages referencing unsupported objects or functions. Check whether the project was originally created for a different WinCC flexible version or a different target panel type.
Update the project's target device settings to match the actual panel being used. Remove or replace any objects or scripts that are not supported by the selected target device. If migrating from an older version, use the project migration wizard to update deprecated elements.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page



