Siemens 6AV6371-1HV38-0AX0 WinCC flexible
€ 1.213,86
The Siemens 6AV6371-1HV38-0AX0 is a software license for WinCC flexible, Siemens' engineering software platform for configuring and commissioning HMI (Human-Machine Interface) panels and visualization systems. It belongs to the SIMATIC WinCC flexible product family and serves as the primary tool for creating HMI projects compatible with the SIMATIC HMI panel range. This software is designed to run on standard engineering PCs and integrates tightly with the SIMATIC automation environment.
WinCC flexible provides a comprehensive set of engineering tools including a graphical editor for screen design, tag management, alarm configuration, recipe management, and scripting capabilities via VBScript. The software supports a wide range of SIMATIC HMI devices including the OP, TP, MP, and Mobile Panel series. It offers integrated communication configuration for PROFIBUS, PROFINET, MPI, and other standard industrial protocols, and supports project simulation directly on the engineering PC without requiring physical hardware. Version HV38 corresponds to a specific release level within the WinCC flexible 2008 generation, offering enhanced compatibility and stability.
WinCC flexible is used across a broad range of industries including manufacturing, automotive, food and beverage, chemical processing, and water treatment. It is the standard engineering environment for facilities that operate SIMATIC HMI panels in conjunction with SIMATIC S7 PLCs. Its tight integration with STEP 7 and the broader TIA Portal migration path makes it suitable for both greenfield installations and the maintenance of existing legacy HMI infrastructure.
Technical Specifications
| Software Platform | WinCC flexible 2008 |
|---|---|
| License Type | Single-user engineering license |
| Compatible HMI Devices | SIMATIC OP, TP, MP, Mobile Panel series |
| Communication Protocols | PROFIBUS, PROFINET, MPI, Ethernet |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Scripting Support | VBScript |
| Simulation | Integrated PC-based project simulation |
| Operating System | Windows XP, Windows Vista, Windows 7 (32/64-bit) |
| Integration | STEP 7, SIMATIC Manager |
| Series/Product Family | SIMATIC WinCC flexible 2008 |
Common Error Codes and System Events
- Event ID: 1000001
- Communication error between HMI panel and PLC. Connection to the configured controller cannot be established.
Check physical communication cable and connectors. Verify PLC address settings and communication parameters in the WinCC flexible project match the controller configuration. - Event ID: 1000002
- Tag read/write error. A configured tag cannot be read from or written to the connected controller.
Verify the tag address exists in the PLC program. Check data type consistency between the HMI tag configuration and the PLC variable. Confirm the PLC is in RUN mode. - Event ID: 1000003
- License not found. The software cannot detect a valid license for the installed WinCC flexible version.
Check that the Siemens Automation License Manager (ALM) is installed and running. Verify the license key is present on the local machine or network license server. Re-transfer the license if necessary. - Event ID: 1000004
- Project compilation error. One or more errors were detected during project compilation preventing download to the HMI panel.
Review the compiler output log for specific error details. Correct all flagged configuration errors in the project, such as missing tag references, invalid screen links, or unsupported functions for the target device. - Event ID: 1000005
- Transfer connection failed. The engineering PC cannot establish a transfer connection to the target HMI panel.
Ensure the HMI panel is in Transfer mode. Verify the IP address or PROFIBUS address of the panel matches the transfer settings in WinCC flexible. Check firewall settings on the engineering PC. - Event ID: 1000006
- Runtime error on HMI panel. The WinCC flexible Runtime application on the panel has encountered an unexpected error and terminated.
Restart the HMI panel. If the error persists, re-download the project from the engineering software. Check for corrupted project files and recompile before transferring. - Event ID: 1000007
- Alarm buffer overflow. The number of pending alarms has exceeded the configured alarm buffer capacity.
Acknowledge and clear existing alarms on the HMI panel. Review the alarm configuration and increase the alarm buffer size in the project settings if necessary. Investigate the root cause of the high alarm volume.
Frequently Asked Questions
Which HMI panels are supported by WinCC flexible 2008 (6AV6371-1HV38-0AX0)?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the OP 73, OP 77, TP 177, TP 277, MP 277, MP 377, and Mobile Panel 177 and 277 series, among others.
Is WinCC flexible compatible with TIA Portal projects?
WinCC flexible projects can be migrated to TIA Portal using the integrated migration tool, but the two environments are not directly interchangeable. Projects created in WinCC flexible must be converted before they can be edited in TIA Portal.
Can WinCC flexible simulate an HMI project without physical hardware?
Yes, WinCC flexible includes an integrated simulation function that allows the project to be tested and validated on the engineering PC without requiring a physical HMI panel.
What operating systems are supported for running WinCC flexible 2008?
WinCC flexible 2008 supports Windows XP (SP3), Windows Vista, and Windows 7 in both 32-bit and 64-bit editions, depending on the specific service pack level installed.
Does this license support communication with S7-1200 or S7-1500 PLCs?
WinCC flexible 2008 has limited or no native support for S7-1200 and S7-1500 PLCs. For these controllers, Siemens recommends using TIA Portal with WinCC Basic or higher.
Troubleshooting
Software installation fails or aborts during setup
Check Windows Event Viewer for installation error codes. Verify that the Automation License Manager is not blocking the installation and that all prerequisites such as .NET Framework and MSXML are installed.
Install all required prerequisites listed in the WinCC flexible 2008 release notes. Disable antivirus software temporarily during installation and run the installer with administrator privileges.
License error appears after installation, software runs in demo mode
Open the Siemens Automation License Manager and check whether a valid WinCC flexible license is listed and assigned to the local machine.
Transfer a valid license from the license storage medium (USB dongle or license file) using the Automation License Manager. If the license was previously on another machine, perform a license transfer back before reassigning.
Project cannot be downloaded to the HMI panel, transfer fails
Verify the HMI panel is set to Transfer mode and that the communication settings (IP address, subnet mask) in WinCC flexible match those configured on the panel.
Correct any mismatched network settings in the project transfer dialog. Ensure no firewall or network switch is blocking the connection between the engineering PC and the HMI panel on the required ports.
Compiled project generates errors referencing unsupported functions
Review the compiler log to identify which functions or objects are flagged. Compare the functions used against the capability list for the specific target HMI device selected in the project.
Replace unsupported functions with compatible alternatives for the target device, or change the target device to one that supports the required functionality. Refer to the WinCC flexible compatibility matrix in the Siemens documentation.
Communication between HMI panel and PLC drops intermittently at runtime
Check the physical communication cable for damage or loose connections. Review the HMI alarm log for communication fault events and note the frequency and timing of dropouts.
Replace or reseat communication cables. Verify PROFIBUS termination resistors are correctly placed at both ends of the bus. For Ethernet connections, check switch port settings and ensure no IP address conflicts exist on the network.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page