• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1HF08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6371-1HF08-0AX0 WinCC flexible 2008

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6371-1HF08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1HF08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC range.

    WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based systems. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS, and Ethernet interfaces. It includes features such as faceplates, scripting via VBScript, alarm management, trend displays, recipe management, and multi-language project support. The 2008 edition introduced improved usability and expanded device support compared to earlier versions.

    WinCC flexible 2008 is used across a broad range of industrial sectors including manufacturing, automotive, food and beverage, chemical processing, and water treatment. It is suitable for machine-level HMI applications where operators require real-time process visualization, alarm handling, and data logging. The software is particularly well-suited for integration into existing SIMATIC automation architectures where standardized engineering tools are required.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user engineering license
    Supported HMI Devices SIMATIC Micro Panels, OP/TP series, Multi Panels, PC-based HMI
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Scripting Support VBScript
    Operating System Windows XP, Windows Vista, Windows 7
    Project Languages Up to 32 languages per project
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000000
    Runtime startup error — WinCC flexible Runtime failed to initialize correctly.
    Check that the correct runtime version is installed and matches the project version. Reinstall the runtime software if necessary.
    Event ID: 1000010
    Communication error — Connection to the configured PLC could not be established.
    Verify PLC address settings, check physical communication cable or network connection, and confirm PLC is powered and in RUN mode.
    Event ID: 1000020
    Tag read/write error — A configured tag could not be read from or written to the PLC.
    Check tag address configuration in the project, verify PLC data block or memory area exists, and confirm communication is active.
    Event ID: 1000030
    License not found — No valid license for WinCC flexible Runtime was detected.
    Ensure the correct license is installed using the Siemens Automation License Manager (ALM). Transfer or activate the license as required.
    Event ID: 1000040
    Project load error — The runtime project file could not be loaded or is corrupted.
    Re-transfer the project from the engineering station to the HMI device. Verify project integrity in WinCC flexible engineering software.
    Event ID: 1000050
    Memory overflow — Available memory on the HMI device is insufficient to run the project.
    Reduce project size by optimizing graphics, reducing the number of tags, or archiving historical data. Consider upgrading to a higher-specification HMI device.
    Event ID: 1000060
    Script execution error — A VBScript function in the project encountered a runtime error.
    Review the VBScript code in the engineering software for syntax or logic errors. Enable script diagnostics to identify the specific failing function.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports a wide range of SIMATIC HMI devices including Micro Panels (KTP series), Operator Panels (OP series), Touch Panels (TP series), Multi Panels (MP series), and PC-based HMI systems running WinCC flexible Runtime.

    Is WinCC flexible 2008 compatible with SIMATIC S7-1200 PLCs?

    Yes, WinCC flexible 2008 supports communication with SIMATIC S7-1200 PLCs via Ethernet using the TCP/IP protocol, though full integration with S7-1200 is more comprehensively supported in TIA Portal-based WinCC.

    What operating systems are supported for running WinCC flexible 2008 engineering software?

    WinCC flexible 2008 is compatible with Windows XP (SP3), Windows Vista, and Windows 7. It is not officially supported on Windows 10 or later without compatibility workarounds.

    Can WinCC flexible 2008 projects be migrated to TIA Portal WinCC?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible 2008 projects to be imported and converted, though some manual rework may be required depending on project complexity.

    What is the difference between WinCC flexible 2008 Standard and Advanced editions?

    The Standard edition supports a limited number of tags and basic functionality, while the Advanced edition supports a larger tag count, additional communication drivers, and extended features such as Sm@rtAccess and Sm@rtService for remote HMI access.

    Troubleshooting

    WinCC flexible Runtime does not start on the HMI device after project transfer

    Check whether the correct Runtime version is installed on the HMI device and whether the license is valid using the Automation License Manager.

    Reinstall the matching WinCC flexible Runtime version on the HMI device and ensure a valid license is present. Re-transfer the project after confirming compatibility.

    No communication between HMI and PLC after project download

    Verify the PLC connection settings in the project, including IP address or MPI/PROFIBUS address, and check the physical communication link between the HMI and PLC.

    Correct the PLC address parameters in the WinCC flexible project, re-transfer the project, and confirm the communication cable or network switch is functioning correctly.

    Tags display '#####' or show no value on the HMI screen

    This typically indicates a communication fault or an incorrectly configured tag address. Check the tag table in the engineering software and verify the PLC data area.

    Correct the tag address in the WinCC flexible tag table to match the actual PLC memory location, then re-transfer the project to the HMI device.

    WinCC flexible engineering software crashes or fails to open a project on the PC

    Check Windows Event Viewer for application errors. Verify that the installed version of WinCC flexible is compatible with the project version and that the PC meets minimum system requirements.

    Repair or reinstall the WinCC flexible 2008 software installation. If the project file is corrupted, restore from a backup or use the project archive function to recover the last saved state.

    License error displayed at Runtime startup despite license being installed

    Open the Siemens Automation License Manager and verify that the license for WinCC flexible Runtime is assigned to the correct hardware (USB dongle or system drive).

    Use the Automation License Manager to transfer or reactivate the license to the correct location. If the license is on a USB dongle, ensure the dongle is connected before starting Runtime.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart