• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1DV48-0AX0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6371-1DV48-0AX0 SIMATIC WinCC

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6371-1DV48-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1DV48-0AX0 is a WinCC (Windows Control Center) SCADA/HMI software package from Siemens, part of the SIMATIC HMI software family. This part number corresponds to a WinCC runtime or configuration license, designed to run on standard PC-based hardware under Windows operating systems. WinCC serves as a powerful process visualization and supervisory control platform for industrial automation environments.

    The software provides a comprehensive set of features including tag-based licensing, process visualization, alarm management, historical data logging, and trend display. It supports a wide range of communication interfaces and drivers, enabling connectivity to SIMATIC S7 PLCs via MPI, PROFIBUS, and Industrial Ethernet (PROFINET), as well as OPC DA/UA for third-party system integration. WinCC includes a scripting environment based on VBScript and ANSI C for custom automation logic, and supports redundant server configurations for high-availability installations.

    WinCC is widely deployed in industries such as automotive manufacturing, chemical processing, water and wastewater treatment, energy management, and building automation. The software is suited for applications requiring centralized process monitoring, data acquisition, and operator control across large-scale distributed systems. Its scalable architecture allows deployment from single-station installations to multi-client/multi-server configurations with thousands of process tags.

    Technical Specifications

    Software Type SCADA / HMI Runtime & Configuration Software
    Platform PC-based (Windows OS)
    Product Family SIMATIC WinCC
    Communication Interfaces MPI, PROFIBUS, PROFINET/Industrial Ethernet, OPC DA, OPC UA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500, and third-party via OPC
    Scripting Support VBScript, ANSI C
    Redundancy Support Yes, server redundancy supported
    Data Logging Process value archiving, alarm logging, user action logging
    Certifications CE
    Operating System Windows (version dependent on WinCC release)
    License Type Floating or single-station license (version dependent)
    Series SIMATIC WinCC V7 / V8 family

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC Runtime startup failure. The runtime process could not be initialized correctly.
    Check Windows Event Viewer for underlying errors. Verify that all required WinCC services are running and that the license dongle or software license is correctly installed.
    Event ID: 1001
    Communication channel to PLC lost. The configured communication driver cannot establish or maintain a connection to the target controller.
    Verify network connectivity and PLC availability. Check channel and connection settings in WinCC Explorer. Confirm correct IP address, MPI address, or PROFIBUS station address is configured.
    Event ID: 10241
    Tag read/write error. A process tag could not be read from or written to the connected PLC.
    Check that the tag address is correctly configured and matches the PLC data block or memory area. Verify the communication connection is active and the PLC program is running.
    Event ID: 112
    License not found or license count exceeded. WinCC cannot find a valid license for the configured number of tags or clients.
    Insert the correct license dongle or verify the software license is activated. Use the Siemens Automation License Manager (ALM) to check license status and available tag count.
    Event ID: 10000
    Archive server error. The WinCC data logging or process value archive has encountered an error and cannot write historical data.
    Check available disk space on the archive drive. Verify that the SQL Server (Microsoft SQL Server used by WinCC) service is running. Review archive configuration in WinCC Explorer.
    Event ID: 1004
    Redundancy switchover event. The WinCC redundant server has switched from the primary to the standby server.
    Investigate the cause of the primary server failure. Check network connectivity, hardware status, and Windows Event Viewer on the primary server. Restore the primary server and perform a manual switchover back if required.
    Event ID: 10200
    User administration error. An operator attempted an action without sufficient access rights, or the user management database is corrupted.
    Verify user roles and access rights in the WinCC User Administrator. If the database is suspected to be corrupted, restore from a backup or reconfigure user accounts.

    Frequently Asked Questions

    What is the tag capacity of the 6AV6371-1DV48-0AX0 WinCC license?

    The exact tag count is encoded in the part number suffix and license type. The 6AV6371-1DV48-0AX0 corresponds to a specific WinCC runtime license tier; consult the Siemens SIMATIC WinCC ordering data sheet or the Automation License Manager to confirm the exact number of process tags included.

    What communication protocols does WinCC support for connecting to PLCs?

    WinCC supports SIMATIC S7 communication via MPI, PROFIBUS DP, and PROFINET/Industrial Ethernet. It also supports OPC DA and OPC UA for integration with third-party controllers and systems, as well as a wide range of additional channel drivers.

    Can WinCC be used in a redundant server configuration?

    Yes, WinCC supports server redundancy where a standby server automatically takes over if the primary server fails, ensuring continuous process monitoring and data logging with minimal interruption.

    What database engine does WinCC use for historical data archiving?

    WinCC uses Microsoft SQL Server as its underlying database engine for process value archiving, alarm logging, and historical data storage. The correct SQL Server version must be installed as a prerequisite.

    Is the 6AV6371-1DV48-0AX0 a runtime-only license or does it include the engineering/configuration environment?

    WinCC licenses typically include both the configuration (CS) and runtime (RT) environments within the same package, allowing engineering and runtime operation on the same station. Confirm the specific license scope in the Siemens product documentation for this part number.

    Troubleshooting

    WinCC Runtime fails to start and displays a license error on launch

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC license is detected. Verify the license dongle is connected or the software license is properly activated on the machine.

    Insert the correct USB license dongle or transfer the software license to the target PC using ALM. Ensure the license tag count matches or exceeds the number of configured process tags in the project.

    No communication between WinCC and the SIMATIC S7 PLC

    Check the WinCC channel diagnostics in WinCC Explorer under the communication driver. Ping the PLC IP address from the WinCC PC to verify basic network connectivity. Confirm the connection parameters (IP address, rack, slot) match the PLC configuration.

    Correct any mismatched connection parameters in the WinCC channel configuration. Verify that the PC network adapter is on the same subnet as the PLC. Ensure no firewall is blocking the S7 communication port (TCP 102). Restart the WinCC channel if necessary.

    Historical data or trend displays show gaps or no data

    Check the WinCC archive configuration and verify that the Microsoft SQL Server service is running. Review available disk space on the archive partition. Check the WinCC diagnostic log for archive-related error events.

    Free up disk space if the archive drive is full. Restart the SQL Server service if it has stopped. Verify that the archive tags are correctly configured and that the archive server is active in the WinCC project.

    WinCC project opens in configuration mode but runtime activation fails

    Review the WinCC output window and system event log for specific error messages during activation. Check for conflicting processes or a previous runtime instance that did not shut down cleanly.

    Restart the WinCC services via the Windows Services console (search for services starting with 'WinCC'). If a previous runtime session is still active in Task Manager, terminate it. Reopen the project and attempt activation again.

    Alarm displays show no alarms even though fault conditions exist in the PLC

    Verify that the alarm tags are correctly mapped to the PLC data addresses in the WinCC Alarm Logging editor. Check that the alarm server is running and that the alarm class and group configurations are correct.

    Correct any incorrect tag addresses in the Alarm Logging configuration. Ensure the alarm server component is active. Test by forcing a known alarm condition in the PLC and confirming whether the tag value changes are reflected in WinCC tag monitoring.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart