• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1DG08-0AX4 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6371-1DG08-0AX4 WinCC flexible 2008

    € 137,94

    Reset
    Clear
    SKU: 6AV6371-1DG08-0AX4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1DG08-0AX4 is a software license for WinCC flexible 2008, part of Siemens' SIMATIC HMI software portfolio. WinCC flexible 2008 is an engineering software package used to configure and program SIMATIC HMI panels, enabling the creation of operator interfaces for industrial automation systems. This specific part number corresponds to the WinCC flexible 2008 Standard edition, which provides a comprehensive set of tools for HMI project development.

    WinCC flexible 2008 Standard offers a project-oriented engineering environment with an intuitive graphical editor for designing process screens, alarm management, trend displays, and recipe handling. The software supports a wide range of SIMATIC HMI devices including the OP, TP, MP, and Mobile Panel series. It provides communication drivers for SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC and other standard protocols. The Standard edition supports multi-user engineering and includes simulation capabilities for offline testing of HMI projects without physical hardware.

    WinCC flexible 2008 is used across a broad range of industries including manufacturing, automotive, food and beverage, chemical processing, and water treatment. It is particularly suited for machine-level HMI applications where operators require clear visualization of process data, alarm handling, and parameter input. The software serves as the primary engineering tool for integrating SIMATIC HMI panels into SIMATIC-based control architectures.

    Technical Specifications

    Software Version WinCC flexible 2008
    Edition Standard
    License Type Single-user license
    Compatible HMI Devices SIMATIC OP, TP, MP, Mobile Panel series
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Protocols SIMATIC S7, OPC DA, Profibus DP, MPI
    Operating System Windows XP (SP2 or higher), Windows Vista, Windows 7
    Engineering Environment Graphical screen editor, alarm management, recipe editor, trend display
    Simulation Integrated offline simulation (without physical HMI hardware)
    Multi-user Engineering Supported
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE

    Common Error Codes and Software Events

    Compiler Error 1
    Project compilation failed due to invalid or missing tag references in screen objects.
    Open the project in WinCC flexible, review the compiler output log, and correct all invalid tag assignments in the affected screens.
    Compiler Error 2
    Overlapping objects detected on a screen during compilation.
    Check the indicated screen for overlapping graphical objects and reposition or resize them to eliminate overlap.
    Transfer Error
    Project transfer to HMI panel failed due to communication or connection issue.
    Verify the PC-to-HMI connection (USB, Ethernet, or MPI/Profibus adapter), confirm the HMI is in transfer mode, and retry the download.
    License Error
    No valid license found for WinCC flexible 2008 Standard.
    Use the Siemens Automation License Manager (ALM) to verify the license is correctly installed and assigned to the local machine or dongle.
    Simulation Runtime Error
    Simulation fails to start or crashes during offline testing.
    Ensure the PC meets minimum system requirements, close conflicting applications, and verify that the WinCC flexible Runtime simulation component is fully installed.
    Tag Limit Exceeded
    The number of configured tags in the project exceeds the limit permitted by the installed license edition.
    Reduce the number of tags in the project or upgrade the WinCC flexible license to a higher edition (e.g., Advanced or Professional).
    Version Mismatch Warning
    The project was created with a different version of WinCC flexible and may not be fully compatible.
    Migrate the project using the built-in migration wizard, review all migrated objects for correctness, and recompile before transfer.

    Frequently Asked Questions

    What HMI panels are supported by WinCC flexible 2008 Standard?

    WinCC flexible 2008 Standard supports the full range of SIMATIC HMI panels including the OP 77, TP 177, MP 277, MP 377, and Mobile Panel series. It does not support the newer Comfort Panel series, which requires WinCC (TIA Portal).

    Which PLCs can communicate with HMI projects configured in WinCC flexible 2008?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, Profibus DP, and Ethernet. Third-party PLCs can be integrated using OPC DA drivers.

    Is WinCC flexible 2008 compatible with Windows 10?

    WinCC flexible 2008 is not officially supported on Windows 10. It was designed for Windows XP SP2, Windows Vista, and Windows 7. Running it on Windows 10 may cause installation or runtime issues.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, WinCC flexible 2008 projects can be migrated to TIA Portal using the integrated migration tool available in TIA Portal V13 and later. Some manual rework may be required after migration.

    Does the Standard edition support multi-language HMI projects?

    Yes, WinCC flexible 2008 Standard supports multi-language project configuration, allowing operators to switch the HMI display language at runtime.

    Troubleshooting

    Software installation fails or aborts partway through

    Check the Windows event log and the WinCC flexible installation log for specific error messages. Verify that the PC meets minimum hardware and OS requirements and that no conflicting software (such as antivirus or previous WinCC versions) is interfering.

    Disable antivirus software during installation, ensure all previous WinCC flexible versions are cleanly uninstalled, and run the installer with administrator privileges. Reboot the PC before retrying.

    License not recognized after installation

    Open the Siemens Automation License Manager (ALM) and check whether the WinCC flexible 2008 Standard license appears and is shown as valid. Verify the license is bound to the correct hardware (local drive or USB dongle).

    If the license is missing, transfer it from the original license medium using ALM. If the dongle is used, ensure it is connected and the dongle driver is installed correctly.

    Project transfer to HMI panel fails with a connection error

    Verify the physical connection between the engineering PC and the HMI panel (USB, Ethernet cable, or MPI/Profibus adapter). Confirm the HMI panel is set to transfer mode and that the correct communication channel is selected in the WinCC flexible transfer settings.

    Correct the communication channel settings in the Transfer dialog, check cable integrity, and ensure the HMI panel firmware version is compatible with the project. Retry the transfer after confirming all settings.

    Simulation does not start or immediately closes

    Check whether the WinCC flexible Runtime simulation component was included during installation. Review the Windows application event log for runtime errors.

    Perform a repair installation of WinCC flexible 2008 to ensure all runtime components are present. Ensure the PC has sufficient RAM and that no firewall rules are blocking the simulation process.

    Compiler reports a large number of errors after opening an existing project

    The project may have been created with a different WinCC flexible version or edition, resulting in incompatible objects or missing tag references after opening.

    Use the migration wizard if the project originates from an older version, then recompile. Manually review and correct any tag or screen object errors reported in the compiler output before attempting a transfer.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart