Siemens 6AV6371-1DG08-0AX4 WinCC flexible 2008
€ 137,94
The Siemens 6AV6371-1DG08-0AX4 is a software license for WinCC flexible 2008, part of Siemens' SIMATIC HMI software portfolio. WinCC flexible 2008 is an engineering software package used to configure and program SIMATIC HMI panels, enabling the creation of operator interfaces for industrial automation systems. This specific part number corresponds to the WinCC flexible 2008 Standard edition, which provides a comprehensive set of tools for HMI project development.
WinCC flexible 2008 Standard offers a project-oriented engineering environment with an intuitive graphical editor for designing process screens, alarm management, trend displays, and recipe handling. The software supports a wide range of SIMATIC HMI devices including the OP, TP, MP, and Mobile Panel series. It provides communication drivers for SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC and other standard protocols. The Standard edition supports multi-user engineering and includes simulation capabilities for offline testing of HMI projects without physical hardware.
WinCC flexible 2008 is used across a broad range of industries including manufacturing, automotive, food and beverage, chemical processing, and water treatment. It is particularly suited for machine-level HMI applications where operators require clear visualization of process data, alarm handling, and parameter input. The software serves as the primary engineering tool for integrating SIMATIC HMI panels into SIMATIC-based control architectures.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Edition | Standard |
| License Type | Single-user license |
| Compatible HMI Devices | SIMATIC OP, TP, MP, Mobile Panel series |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Protocols | SIMATIC S7, OPC DA, Profibus DP, MPI |
| Operating System | Windows XP (SP2 or higher), Windows Vista, Windows 7 |
| Engineering Environment | Graphical screen editor, alarm management, recipe editor, trend display |
| Simulation | Integrated offline simulation (without physical HMI hardware) |
| Multi-user Engineering | Supported |
| Series/Product Family | SIMATIC WinCC flexible |
| Certifications | CE |
Common Error Codes and Software Events
- Compiler Error 1
- Project compilation failed due to invalid or missing tag references in screen objects.
Open the project in WinCC flexible, review the compiler output log, and correct all invalid tag assignments in the affected screens. - Compiler Error 2
- Overlapping objects detected on a screen during compilation.
Check the indicated screen for overlapping graphical objects and reposition or resize them to eliminate overlap. - Transfer Error
- Project transfer to HMI panel failed due to communication or connection issue.
Verify the PC-to-HMI connection (USB, Ethernet, or MPI/Profibus adapter), confirm the HMI is in transfer mode, and retry the download. - License Error
- No valid license found for WinCC flexible 2008 Standard.
Use the Siemens Automation License Manager (ALM) to verify the license is correctly installed and assigned to the local machine or dongle. - Simulation Runtime Error
- Simulation fails to start or crashes during offline testing.
Ensure the PC meets minimum system requirements, close conflicting applications, and verify that the WinCC flexible Runtime simulation component is fully installed. - Tag Limit Exceeded
- The number of configured tags in the project exceeds the limit permitted by the installed license edition.
Reduce the number of tags in the project or upgrade the WinCC flexible license to a higher edition (e.g., Advanced or Professional). - Version Mismatch Warning
- The project was created with a different version of WinCC flexible and may not be fully compatible.
Migrate the project using the built-in migration wizard, review all migrated objects for correctness, and recompile before transfer.
Frequently Asked Questions
What HMI panels are supported by WinCC flexible 2008 Standard?
WinCC flexible 2008 Standard supports the full range of SIMATIC HMI panels including the OP 77, TP 177, MP 277, MP 377, and Mobile Panel series. It does not support the newer Comfort Panel series, which requires WinCC (TIA Portal).
Which PLCs can communicate with HMI projects configured in WinCC flexible 2008?
WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, Profibus DP, and Ethernet. Third-party PLCs can be integrated using OPC DA drivers.
Is WinCC flexible 2008 compatible with Windows 10?
WinCC flexible 2008 is not officially supported on Windows 10. It was designed for Windows XP SP2, Windows Vista, and Windows 7. Running it on Windows 10 may cause installation or runtime issues.
Can WinCC flexible 2008 projects be migrated to TIA Portal?
Yes, WinCC flexible 2008 projects can be migrated to TIA Portal using the integrated migration tool available in TIA Portal V13 and later. Some manual rework may be required after migration.
Does the Standard edition support multi-language HMI projects?
Yes, WinCC flexible 2008 Standard supports multi-language project configuration, allowing operators to switch the HMI display language at runtime.
Troubleshooting
Software installation fails or aborts partway through
Check the Windows event log and the WinCC flexible installation log for specific error messages. Verify that the PC meets minimum hardware and OS requirements and that no conflicting software (such as antivirus or previous WinCC versions) is interfering.
Disable antivirus software during installation, ensure all previous WinCC flexible versions are cleanly uninstalled, and run the installer with administrator privileges. Reboot the PC before retrying.
License not recognized after installation
Open the Siemens Automation License Manager (ALM) and check whether the WinCC flexible 2008 Standard license appears and is shown as valid. Verify the license is bound to the correct hardware (local drive or USB dongle).
If the license is missing, transfer it from the original license medium using ALM. If the dongle is used, ensure it is connected and the dongle driver is installed correctly.
Project transfer to HMI panel fails with a connection error
Verify the physical connection between the engineering PC and the HMI panel (USB, Ethernet cable, or MPI/Profibus adapter). Confirm the HMI panel is set to transfer mode and that the correct communication channel is selected in the WinCC flexible transfer settings.
Correct the communication channel settings in the Transfer dialog, check cable integrity, and ensure the HMI panel firmware version is compatible with the project. Retry the transfer after confirming all settings.
Simulation does not start or immediately closes
Check whether the WinCC flexible Runtime simulation component was included during installation. Review the Windows application event log for runtime errors.
Perform a repair installation of WinCC flexible 2008 to ensure all runtime components are present. Ensure the PC has sufficient RAM and that no firewall rules are blocking the simulation process.
Compiler reports a large number of errors after opening an existing project
The project may have been created with a different WinCC flexible version or edition, resulting in incompatible objects or missing tag references after opening.
Use the migration wizard if the project originates from an older version, then recompile. Manually review and correct any tag or screen object errors reported in the compiler output before attempting a transfer.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro