• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1DG08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6371-1DG08-0AX0 WinCC flexible 2008

    € 880,76

    Reset
    Clear
    SKU: 6AV6371-1DG08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1DG08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible SCADA and HMI engineering software family. This product provides the engineering environment used to configure, program, and commission Siemens HMI panels across the SIMATIC HMI portfolio. It is designed for use on standard engineering PCs running compatible Windows operating systems.

    WinCC flexible 2008 offers a scalable engineering framework supporting the full range of Siemens HMI devices, from Micro Panels and Mobile Panels to Multi Panels and PC-based systems. The software includes a library of pre-built function blocks, faceplates, and symbol libraries to accelerate project development. It supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. The platform also supports multi-language project management, allowing HMI screens to be configured in multiple languages simultaneously.

    WinCC flexible 2008 is widely used in manufacturing, process automation, and machine building applications where Siemens SIMATIC HMI panels are deployed. It is particularly suited for OEMs and system integrators who develop standardized machine HMI solutions across multiple panel types. The software enables centralized project management, simulation of HMI projects on the engineering PC, and seamless integration with STEP 7 for combined PLC and HMI engineering workflows.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user engineering license
    Compatible HMI Devices SIMATIC HMI Micro Panels, Mobile Panels, Operator Panels, Multi Panels, Panel PCs
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit/64-bit)
    Integration STEP 7 integration supported
    Language Support Multi-language project management
    Simulation HMI project simulation on engineering PC
    Series/Product Family WinCC flexible
    Certifications CE

    Common Error Codes & System Events

    Compiler Error 1
    Project compilation failed due to invalid tag configuration or missing PLC connection assignment.
    Review all tag definitions and ensure each tag is assigned to a valid PLC connection. Recompile the project after corrections.
    Compiler Error 2
    Screen object references a tag that does not exist in the tag database.
    Open the tag editor and verify that all tags referenced by screen objects are correctly defined. Remove or reassign orphaned references.
    Transfer Error
    Project transfer to HMI panel failed, typically due to incorrect transfer channel settings or network misconfiguration.
    Verify the transfer channel settings match the physical connection (MPI address, PROFIBUS address, or IP address). Ensure the HMI panel is in transfer mode before initiating download.
    License Error
    Software reports missing or invalid license, preventing project editing or compilation.
    Run the Automation License Manager to verify the WinCC flexible license is correctly installed and not expired. Reinstall the license key if necessary.
    Simulation Error
    HMI project simulation fails to start on the engineering PC.
    Ensure the WinCC flexible Runtime simulation component is installed. Check that no firewall or antivirus software is blocking the simulation process.
    Consistency Check Warning
    Consistency check detects mismatched data types between PLC tags and HMI tags.
    Open the tag editor and align the data types of HMI tags with the corresponding PLC variable types. Re-run the consistency check after corrections.
    Connection Timeout
    Online connection to the HMI panel is lost or cannot be established during transfer or diagnostics.
    Check physical cable connections and network settings. Verify the HMI panel IP address or MPI/PROFIBUS address matches the project configuration.

    Frequently Asked Questions

    Which Siemens HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI devices including Micro Panels (TP 170 Micro), Mobile Panels, Operator Panels (OP 77B, OP 177B), Multi Panels (MP 277, MP 377), and Panel PCs.

    Is WinCC flexible 2008 compatible with TIA Portal?

    WinCC flexible 2008 is not part of the TIA Portal framework. Siemens provides a migration tool to convert WinCC flexible projects to WinCC in TIA Portal, but the two engineering environments are separate.

    Which PLC families can be connected to HMI projects created in WinCC flexible 2008?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC or other supported drivers.

    Can WinCC flexible 2008 simulate HMI projects without a physical panel?

    Yes, WinCC flexible 2008 includes a built-in simulation function that allows HMI projects to be tested and simulated directly on the engineering PC without requiring a physical HMI panel.

    What operating systems are supported by WinCC flexible 2008?

    WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7 in both 32-bit and 64-bit editions, subject to the specific service pack requirements defined in the product release notes.

    Troubleshooting

    Project transfer to HMI panel fails repeatedly

    Check the transfer channel configuration in WinCC flexible under Transfer Settings. Verify the physical connection type (USB, Ethernet, MPI) and confirm the HMI panel is set to transfer mode.

    Correct the IP address, MPI node address, or COM port settings to match the actual hardware configuration. Restart the HMI panel in transfer mode and retry the download.

    WinCC flexible 2008 reports a license error on startup

    Open the Siemens Automation License Manager and check whether a valid WinCC flexible 2008 license is present and assigned to the local machine.

    If the license is missing or on a different machine, transfer the license using the Automation License Manager. If the license dongle is used, ensure it is connected to the USB port before launching the software.

    Compilation errors appear for tags with no visible configuration issues

    Run the project consistency check under the Tools menu to identify all tag and screen object conflicts. Look for data type mismatches or deleted tags still referenced by screen objects.

    Correct all data type mismatches in the tag editor and remove or reassign any orphaned tag references in screen objects. Recompile the project after all issues are resolved.

    HMI simulation crashes or does not start

    Verify that the WinCC flexible Runtime simulation component was selected during software installation. Check Windows Event Viewer for application errors related to the simulation executable.

    Reinstall WinCC flexible 2008 and ensure the simulation component is included in the installation. Temporarily disable antivirus software to rule out interference with the simulation process.

    Existing WinCC flexible project cannot be opened after software reinstallation

    Check the WinCC flexible version used to create the project. Projects created with a newer service pack or version may not open in an older installation.

    Install the correct WinCC flexible 2008 service pack that matches the project version. Use the project version information displayed in the error dialog to identify the required software update.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart