• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1AF10-0AX0 WinCC flexible
    Awaiting product image

    Siemens 6AV6371-1AF10-0AX0 WinCC flexible

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6371-1AF10-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1AF10-0AX0 is a software license for WinCC flexible, Siemens' engineering software platform for configuring and commissioning HMI (Human-Machine Interface) panels within the SIMATIC HMI product family. This part number corresponds to a specific edition or upgrade of WinCC flexible, designed to work in conjunction with Siemens SIMATIC HMI hardware such as the TP, OP, MP, and Mobile Panel series. The software runs on a standard engineering PC and provides the development environment for creating HMI visualization projects.

    WinCC flexible offers a comprehensive set of engineering tools including a graphical project editor, tag management, alarm logging, recipe management, and script-based automation using VBScript. It supports a wide range of communication drivers enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC and other industrial protocols. The software supports multi-language project configuration, faceplates, and library management for reusable graphical objects. Integration with STEP 7 and the broader TIA Portal ecosystem is supported depending on the version.

    WinCC flexible is used across a broad range of industrial sectors including manufacturing, automotive, food and beverage, chemical processing, and water treatment. It is the standard engineering tool for configuring Siemens SIMATIC HMI panels deployed on production lines, packaging machines, process control stations, and machine tool applications. Its scalability from small Micro Panels to large multi-panel installations makes it suitable for both simple operator terminals and complex SCADA-level visualization systems.

    Technical Specifications

    Software Type HMI Engineering Software
    Product Family WinCC flexible
    Compatible HMI Hardware SIMATIC HMI TP, OP, MP, Mobile Panel series
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Protocols MPI, PROFIBUS, PROFINET, OPC, Ethernet
    Scripting Support VBScript
    Operating System Windows XP / Windows 7 (32-bit)
    License Type Single-user software license
    Integration STEP 7, TIA Portal (version dependent)
    Series WinCC flexible 2008 or earlier edition

    Common Error Codes & System Events

    Event ID: 1000001
    Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been interrupted.
    Check physical communication cable and connector integrity. Verify PLC address settings and communication parameters in the WinCC flexible project match the controller configuration.
    Event ID: 1000002
    Tag read/write error. A configured tag cannot be read from or written to the connected PLC.
    Verify the tag address exists in the PLC program and that the data type in WinCC flexible matches the PLC variable type. Check PLC is in RUN mode.
    Event ID: 1000003
    License not found or invalid license detected during software startup.
    Ensure the correct WinCC flexible license is installed using the Siemens Automation License Manager (ALM). Transfer or repair the license as required.
    Event ID: 1000004
    Project transfer failed. Download of the HMI project to the target panel was unsuccessful.
    Check the transfer cable or network connection between the engineering PC and the HMI panel. Ensure the panel is in transfer mode and the correct transfer channel is selected in WinCC flexible.
    Event ID: 1000005
    Runtime error on HMI panel. The project runtime has encountered an internal fault and may have stopped.
    Restart the HMI panel. If the fault persists, re-transfer the project from WinCC flexible. Check available panel memory and reduce project size if necessary.
    Event ID: 1000006
    Alarm buffer overflow. The number of pending alarms has exceeded the configured alarm buffer capacity.
    Acknowledge and clear existing alarms. Increase the alarm buffer size in the WinCC flexible project settings or reduce the frequency of alarm triggers in the PLC program.
    Event ID: 1000007
    Recipe data error. A recipe record could not be read from or written to the panel memory or external storage.
    Check that the recipe configuration in WinCC flexible matches the expected data structure. Verify available storage capacity on the panel or connected memory card.

    Frequently Asked Questions

    What HMI panels are compatible with WinCC flexible 6AV6371-1AF10-0AX0?

    WinCC flexible is compatible with the SIMATIC HMI range including TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. The specific panels supported depend on the software edition installed.

    Is WinCC flexible compatible with TIA Portal?

    WinCC flexible is a separate engineering environment from TIA Portal. While some migration tools exist to import WinCC flexible projects into TIA Portal WinCC, the two platforms are not directly interchangeable. Siemens recommends TIA Portal for new projects.

    What operating systems are supported for installing WinCC flexible?

    WinCC flexible is designed for Windows XP and Windows 7 (32-bit) operating systems. It is not natively supported on Windows 10 or later without compatibility measures.

    Can WinCC flexible communicate with third-party PLCs?

    Yes, WinCC flexible supports OPC communication and includes drivers for a number of third-party controllers in addition to the native SIMATIC S7 protocol drivers.

    What is the Automation License Manager and is it required?

    The Siemens Automation License Manager (ALM) is a tool used to manage software licenses for Siemens automation products including WinCC flexible. It is required to validate and activate the software license supplied with this part number.

    Troubleshooting

    WinCC flexible software fails to start and displays a license error

    The Automation License Manager cannot find a valid license for WinCC flexible on the engineering PC. This may occur after a hard drive replacement or OS reinstallation.

    Open the Siemens Automation License Manager, check for the presence of the WinCC flexible license, and transfer or repair it from the original license medium. Ensure the license matches the installed software edition.

    Project cannot be transferred to the HMI panel

    The transfer connection between the engineering PC and the HMI panel is not established. Check whether the panel is in transfer mode and verify the selected transfer channel (USB, Ethernet, or MPI/PROFIBUS) in WinCC flexible matches the physical connection.

    Set the HMI panel to transfer mode via its loader menu. Confirm the correct interface is selected in WinCC flexible under Transfer settings. Check cable integrity and firewall settings on the PC that may block the transfer port.

    HMI panel shows no communication to PLC after project download

    The communication parameters configured in WinCC flexible do not match the actual PLC settings. This includes PLC address, subnet, or protocol mismatch.

    Open the WinCC flexible project and verify the connection settings including PLC IP address or MPI/PROFIBUS address, baud rate, and protocol. Correct any mismatches and re-transfer the project to the panel.

    Alarms configured in WinCC flexible do not appear on the HMI panel at runtime

    The alarm tags may be incorrectly addressed or the alarm class configuration is incomplete. The PLC bits triggering the alarms may not be set correctly.

    Verify the bit addresses used for alarm triggers in WinCC flexible match the corresponding PLC variables. Check the alarm class settings and ensure alarms are enabled in the runtime project. Test by manually setting the trigger bits in the PLC.

    WinCC flexible project editor crashes or becomes unresponsive during editing

    This may be caused by insufficient PC resources, a corrupted project file, or incompatibility between the software version and the operating system.

    Ensure the engineering PC meets the minimum hardware requirements for WinCC flexible. Close unnecessary applications to free memory. If the project file is corrupted, restore from a backup. Verify that all relevant Windows service packs and WinCC flexible patches are installed.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart