• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6362-4AA07-5AK0 SIMATIC HMI TP 177A
    Awaiting product image

    Siemens 6AV6362-4AA07-5AK0 SIMATIC HMI TP 177A

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6362-4AA07-5AK0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6362-4AA07-5AK0 is a Touch Panel belonging to the SIMATIC HMI TP 177A series, part of Siemens' 177 panel family designed for human-machine interface applications in industrial automation environments. This unit provides a compact and robust operator panel solution with a resistive touchscreen display, intended for use with Siemens SIMATIC S7 and other compatible PLC systems. It is engineered for straightforward machine-level visualization and control tasks where a reliable, cost-effective HMI solution is required.

    The TP 177A features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), supporting up to 256 colors for clear process visualization. The panel operates on a 24 V DC supply and communicates via a PROFIBUS DP interface, enabling direct integration into existing PROFIBUS networks. Configuration is performed using Siemens WinCC flexible software, and the unit includes internal flash memory for project and recipe storage. The housing is rated IP65 on the front panel, providing protection against dust and water ingress in demanding industrial environments.

    The SIMATIC TP 177A is widely deployed in machine building, manufacturing automation, and process control applications where a compact touch-operated HMI is needed at the machine level. It is commonly found in packaging machinery, conveyor systems, and general-purpose industrial machines across sectors such as automotive, food and beverage, and discrete manufacturing. Its compatibility with SIMATIC S7-200 and S7-300 PLCs via PROFIBUS makes it a practical choice for integration into existing Siemens automation architectures.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels (QVGA)
    Display Type STN color
    Display Colors 256 colors
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 6 W
    Communication Interface PROFIBUS DP
    Configuration Software WinCC flexible
    IP/Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been lost.
    Check PROFIBUS cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to PLC interrupted during runtime. The HMI has lost communication with the configured controller.
    Inspect PROFIBUS wiring for damage or loose connectors. Check bus termination at both ends of the network. Restart the HMI and PLC if the connection is not restored automatically.
    Event ID: 20000
    Project download error. The project transfer from the configuration PC to the HMI panel has failed.
    Verify the transfer cable connection and communication settings. Ensure the HMI is in transfer mode before initiating the download. Check that the WinCC flexible project is compatible with the panel firmware version.
    Event ID: 40000
    System memory low. Available memory on the HMI panel is insufficient for the current project or runtime operation.
    Reduce the size of the project by removing unused screens, graphics, or recipes. Delete unnecessary data records stored on the device. Consider archiving data to an external storage medium if supported.
    Event ID: 50000
    Firmware update error. An error occurred during a firmware update procedure on the panel.
    Restart the panel and attempt the firmware update again using the correct firmware version for this panel type. Ensure a stable power supply during the update process. If the error persists, contact Siemens technical support.
    Event ID: 60000
    Configuration error detected. The loaded project contains settings or objects that are incompatible with the current panel hardware or firmware.
    Recompile the project in WinCC flexible and verify that the correct panel type and firmware version are selected. Re-download the corrected project to the panel.
    Event ID: 70000
    Operating system error. An internal system fault has occurred within the HMI panel runtime environment.
    Perform a warm restart of the panel. If the error recurs, perform a factory reset and reload the project. Check for firmware updates that may address known runtime issues.

    Frequently Asked Questions

    What PLC systems are compatible with the SIMATIC TP 177A?

    The TP 177A is compatible with Siemens SIMATIC S7-200 and S7-300 PLCs via PROFIBUS DP. It can also communicate with other PROFIBUS-capable controllers depending on the driver support in WinCC flexible.

    What software is required to configure the TP 177A?

    The panel is configured using Siemens WinCC flexible software. The project is then transferred to the panel via a PC adapter or MPI/PROFIBUS connection.

    What is the supply voltage for the 6AV6362-4AA07-5AK0?

    The panel requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range to avoid operational issues.

    What is the front panel protection rating of the TP 177A?

    The front panel of the TP 177A is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for use in industrial machine enclosures.

    Can the TP 177A display be used in portrait orientation?

    The TP 177A is designed for landscape orientation and does not natively support portrait mode rotation in its standard configuration.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify that the supply is within the specified range and that the connector is fully seated.

    Restore correct supply voltage if out of range. If voltage is correct and display remains blank, inspect the internal fuse and replace if blown. If the panel still does not power on, the internal power supply board may require replacement.

    Touchscreen does not respond to input or responds inaccurately

    Determine whether the issue is a complete lack of response or positional inaccuracy. A calibration drift is common after extended use or physical impact.

    Perform a touchscreen recalibration via the panel's system settings menu. If the screen is completely unresponsive, inspect for physical damage to the touch surface. A damaged resistive touch layer will require panel repair or replacement.

    HMI cannot establish communication with the PLC

    Verify the PROFIBUS DP cable connections at both the HMI and PLC ends. Check that bus termination resistors are correctly installed at the network endpoints and that the PROFIBUS address configured in the HMI project matches the physical PLC address.

    Correct any wiring faults or address mismatches. Replace damaged PROFIBUS connectors or cable segments. Ensure the PLC is powered and in RUN mode before starting the HMI runtime.

    Project download fails during transfer from PC to panel

    Confirm that the HMI panel is set to transfer mode before initiating the download. Check the communication cable and port settings on the PC side.

    Switch the panel to transfer mode via the start center menu. Verify the correct COM port and transfer settings in WinCC flexible. Ensure the project is compiled without errors before attempting the transfer.

    Panel displays repeated system event messages during runtime

    Note the specific event IDs displayed. These typically indicate communication loss, memory issues, or configuration mismatches between the project and the connected PLC.

    Address the root cause indicated by the event ID, such as restoring PLC communication, freeing panel memory, or re-downloading a corrected project. Clear the event log after resolving the underlying issue.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart