Siemens 6AV6355-1CA47-7HC3 OP 77B
€ 1.995,00
The Siemens 6AV6355-1CA47-7HC3 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. It is a compact, key-operated panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling automated processes. This unit is part of the SIMATIC HMI Basic Panels generation and is manufactured by Siemens AG as part of their industrial automation portfolio.
The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels and a backlit screen for clear readability in varying ambient light conditions. It supports communication via PROFIBUS DP and MPI interfaces, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs without the need for additional gateways. The panel is configured using WinCC flexible software and offers a membrane keypad with function keys for operator input, along with a robust housing rated for industrial environments.
The OP 77B is widely used in manufacturing, packaging, and process automation industries where a cost-effective, reliable operator interface is required at the machine level. Its compact form factor and compatibility with the SIMATIC S7 controller family make it suitable for integration into control cabinets and machine panels. Applications include conveyor systems, pump stations, mixing equipment, and general-purpose machine control where basic process visualization and parameter entry are needed.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Display Size | 4 inch |
| Input Voltage | 24 V DC |
| Power Consumption | Max. 4.5 W |
| Communication Interface | PROFIBUS DP, MPI |
| Configuration Software | WinCC flexible 2005 or higher |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series | SIMATIC HMI OP 77B |
Common Error Codes and System Events
- Event ID: 10000
- Configuration error detected on the panel, indicating a mismatch or corrupted project data.
Re-transfer the project from WinCC flexible to the panel. Verify project compatibility with the panel firmware version. - Event ID: 20000
- Communication error between the HMI panel and the connected PLC via MPI or PROFIBUS DP.
Check cable connections and bus termination resistors. Verify the MPI/PROFIBUS address settings on both the panel and PLC match the project configuration. - Event ID: 40000
- Tag read/write error indicating the panel cannot access a configured PLC data address.
Verify the PLC program contains the correct data blocks and addresses referenced in the HMI project. Check PLC operating mode. - Event ID: 50000
- Panel operating system or firmware error detected during startup or runtime.
Perform a panel reset and re-transfer the operating system using WinCC flexible or ProSave. If the issue persists, the panel may require service. - Event ID: 70000
- Backlight failure or display hardware fault detected.
Check the 24 V DC supply voltage at the panel connector. If supply is correct, the backlight unit may require replacement or the panel should be sent for repair. - Event ID: 60000
- Project transfer error during download from the engineering PC to the panel.
Ensure the correct transfer cable is used and the panel is set to transfer mode. Check PC communication port settings and WinCC flexible project integrity.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B panel?
The OP 77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via PPI protocol.
What software is required to configure the 6AV6355-1CA47-7HC3?
This panel is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via a PC adapter cable connected to the MPI interface.
What is the supply voltage for this operator panel?
The OP 77B requires a 24 V DC supply voltage for operation.
What is the IP protection rating of the OP 77B?
The front face of the panel is rated IP65, providing protection against dust and water jets. The rear of the panel is rated IP20.
Can the OP 77B display graphics and trend curves?
The OP 77B supports basic graphics and bar graphs on its monochrome display, but advanced trend curve visualization is limited due to the display resolution and panel class.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel's power connector. Check for correct polarity. Inspect the internal fuse if accessible.
Correct any wiring errors or supply voltage issues. If the supply is confirmed at 24 V DC and the display remains blank, the backlight or internal power circuitry may be faulty and the panel should be repaired or replaced.
Panel shows persistent communication error with PLC
Check the MPI or PROFIBUS DP cable for continuity and correct termination at both ends of the bus. Verify the bus address configured in the HMI project matches the physical address set on the panel.
Replace damaged cables, ensure bus termination resistors are correctly placed at both ends of the network, and confirm address settings in WinCC flexible match the panel and PLC configuration.
Panel fails to enter transfer mode for project download
Confirm the panel is set to transfer mode via the Start Center menu. Check that the PC adapter cable is correctly connected and the COM port or USB settings in WinCC flexible match the adapter.
Restart the panel and select Transfer from the Start Center. Reinstall the PC adapter driver on the engineering PC if necessary and retry the project transfer.
Operator inputs via membrane keypad are not responding
Test each key individually in the panel's diagnostic or test mode if available. Inspect the keypad membrane for physical damage or contamination around the key area.
Clean the keypad surface with a dry cloth. If individual keys are unresponsive due to membrane damage, the keypad membrane assembly should be replaced by a qualified technician.
Panel restarts repeatedly or does not complete boot sequence
Check the 24 V DC supply for voltage drops or instability under load. Verify that the firmware version on the panel is compatible with the loaded project.
Stabilize the power supply and ensure adequate current capacity. Re-transfer the operating system using ProSave to restore a clean firmware state, then re-download the project.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page