Siemens 6AV6355-1CA47-7EU0 OP 77B
€ 862,96
The Siemens 6AV6355-1CA47-7EU0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. This compact operator panel is designed for straightforward machine-level visualization and operator control tasks, providing a reliable human-machine interface solution for industrial automation environments. It is manufactured by Siemens as part of the broader SIMATIC HMI portfolio, which integrates seamlessly with Siemens PLC and automation systems.
The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels and a membrane keypad for operator input, eliminating the need for a touchscreen while providing robust tactile control. It supports the MPI and PROFIBUS DP communication interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and offers a compact, panel-mount design with an IP65 protection rating on the front face, making it suitable for use in environments where dust and water ingress are a concern.
The OP 77B is commonly deployed in manufacturing, packaging, and process automation applications where a cost-effective, reliable operator interface is required at the machine level. Its keypad-based operation makes it well-suited for environments where touchscreen panels may be impractical due to operator glove use or harsh conditions. The panel is frequently found on standalone machines, conveyor systems, and small-scale process control installations across industries such as food and beverage, automotive, and general manufacturing.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Display Size | 4 inches (diagonal) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 4.8 W (typical) |
| Communication Interface | MPI, PROFIBUS DP |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC HMI OP 77B |
| Configuration Software | WinCC flexible 2005 or higher |
| Certifications | CE, UL, cULus |
Common Error Codes and System Events
- Event ID: 1000
- Connection to PLC lost or communication timeout on MPI/PROFIBUS DP interface.
Check MPI/PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and running. Check configured station address and baud rate in WinCC flexible project. - Event ID: 1003
- Tag read error — the panel cannot read a configured tag from the connected PLC.
Verify the tag address exists in the PLC program and the data block is present. Check communication connection status and ensure the PLC program is loaded and running. - Event ID: 1004
- Tag write error — the panel cannot write a value to a configured tag in the PLC.
Check that the target tag address is not write-protected in the PLC. Verify communication link integrity and confirm the PLC is in RUN mode. - Event ID: 10000
- System event: Panel startup or initialization completed.
Informational event. No corrective action required. If panel fails to complete startup, check 24 V DC supply voltage and integrity of the configuration project. - Event ID: 10001
- Project download error — configuration transfer from PC to panel failed or was interrupted.
Restart the download process using WinCC flexible. Ensure the correct communication interface and transfer settings are selected. Check the USB or serial cable connection between PC and panel. - Event ID: 20000
- Internal device error or hardware fault detected on the operator panel.
Cycle power to the panel. If the fault persists, perform a factory reset via the panel's loader menu. If unresolved, the panel may require repair or replacement. - Event ID: 10002
- Insufficient memory — the project loaded onto the panel exceeds available flash memory.
Reduce the project size in WinCC flexible by removing unused screens, tags, or graphics. Reload the optimized project to the panel.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7EU0)?
The OP 77B supports direct connection to Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It is not natively compatible with S7-1200 or S7-1500 PLCs.
What software is used to configure and program the OP 77B?
The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via a serial or USB-to-serial connection.
What is the supply voltage for the OP 77B?
The panel operates on a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to avoid damage or malfunction.
Does the OP 77B have a touchscreen?
No, the OP 77B uses a membrane keypad for operator input and does not feature a touchscreen. This makes it suitable for environments where operators wear gloves or where touchscreen reliability may be a concern.
What is the front panel protection rating of the OP 77B?
The front face of the OP 77B carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets when correctly installed in a panel cutout.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel's power connector. Check for blown internal fuses or wiring faults. Verify the supply is within the specified voltage tolerance.
Correct any wiring issues and ensure the 24 V DC supply is stable and within tolerance. If the display remains blank with correct supply voltage, the internal power supply or display backlight may have failed and the unit should be sent for repair.
Panel displays 'No connection to PLC' or communication error on startup
Check the MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Verify the bus termination resistors are correctly placed at both ends of the network. Confirm the station address and baud rate in the WinCC flexible project match the PLC configuration.
Reseat all communication connectors, correct bus termination, and ensure the configured MPI/PROFIBUS address and baud rate match the PLC settings. Reload the project if configuration changes are made.
Project download from PC to panel fails or times out
Check the serial or USB-to-serial cable connection between the PC and the panel. Verify the correct COM port and transfer settings are selected in WinCC flexible. Ensure the panel is in transfer mode via the loader menu.
Use a known-good USB-to-serial adapter and cable. Set the panel to transfer mode manually through the loader. Retry the download with the correct port settings in WinCC flexible.
Operator keys are unresponsive or register incorrect inputs
Inspect the membrane keypad for physical damage, contamination, or deformation. Test individual keys in the panel's loader or service menu if available.
Clean the keypad surface with a dry cloth. If keys remain unresponsive after cleaning, the membrane keypad assembly may be worn or damaged and requires replacement.
Panel repeatedly reboots or freezes during operation
Check the 24 V DC supply for voltage dips or instability under load. Inspect the project for configuration errors such as cyclic tag polling overloads or corrupted project data.
Stabilize the power supply and add filtering if necessary. Reload a verified project to the panel. If rebooting continues with a stable supply and clean project, the panel hardware may be faulty and should be inspected for repair.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page