• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7ER5 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7ER5 OP 77B

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1CA47-7ER5 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7ER5 is an operator panel belonging to the OP 77B series within Siemens' SIMATIC HMI product line. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a text-based display and keypad input for process monitoring and control. It is part of the broader SIMATIC HMI Basic Panels family, intended for straightforward visualization tasks in industrial environments.

    The OP 77B features a monochrome STN LCD display capable of showing text and simple graphics, paired with a membrane keypad for operator input. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and offers a compact, robust housing suitable for panel mounting with an IP65 protection rating on the front face.

    The OP 77B is commonly deployed in manufacturing machinery, packaging equipment, conveyor systems, and process automation installations where a cost-effective, reliable operator interface is required. Its compatibility with the SIMATIC S7 controller family makes it a practical choice for system integrators working within established Siemens automation architectures. The panel is well-suited for applications requiring basic parameter display, alarm acknowledgment, and simple operator input functions.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Size 4 lines x 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption 4.5 W
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible 2005 or higher
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings and baud rate configuration in WinCC flexible match the physical network settings.
    Event ID: 10001
    Timeout error on the communication link. The PLC did not respond within the expected time window.
    Check network cable integrity and connector pins. Verify the PLC is in RUN mode and that the configured station address is correct.
    Event ID: 20000
    Tag read error. The HMI panel was unable to read a configured tag from the PLC.
    Verify the tag address configured in WinCC flexible exists in the PLC program. Check that the data block or memory area referenced is present and accessible.
    Event ID: 20001
    Tag write error. The HMI panel was unable to write a value to a configured PLC tag.
    Check that the target PLC memory area is not write-protected. Verify the tag address and data type match the PLC program definition.
    Event ID: 40000
    Project download error. The project transfer from the configuration PC to the HMI panel failed.
    Ensure the correct communication interface and transfer settings are selected in WinCC flexible. Check the cable connection between the PC and the panel and verify the panel is in transfer mode.
    Event ID: 50000
    System memory low. The HMI panel is running low on available runtime memory.
    Reduce the number of active alarms, screens, or logged data entries. Consider optimizing the project configuration to reduce memory usage.
    Event ID: 60000
    Internal device error. A hardware or firmware fault has been detected within the panel.
    Perform a power cycle of the panel. If the error persists, perform a factory reset via the panel's loader menu. If unresolved, the unit may require repair or replacement.
    Event ID: 70000
    Configuration error. The loaded project is incompatible with the current firmware version of the panel.
    Update the panel firmware to the version required by the WinCC flexible project, or recompile and re-download the project using a compatible version of WinCC flexible.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B panel?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports communication with SIMATIC S5 controllers and certain third-party controllers through configurable drivers in WinCC flexible.

    What software is required to configure the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. The project is compiled and transferred to the panel via the MPI interface or a direct PC adapter cable.

    What is the supply voltage for the 6AV6355-1CA47-7ER5?

    The panel operates on a 24 V DC supply voltage. The power consumption is approximately 4.5 W under normal operating conditions.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets. The rear of the unit is rated IP20.

    Can the OP 77B display graphics or only text?

    The OP 77B is primarily a text-based operator panel with a character-based monochrome LCD. It supports basic bar graph elements but is not designed for bitmap graphics or complex graphical visualization.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check for correct polarity. Inspect the supply cable for damage or loose connections.

    Correct any wiring faults and ensure the supply voltage is within the specified 24 V DC range. If the supply is confirmed correct and the display remains blank, the internal power supply or display unit may be faulty and the panel should be sent for repair.

    HMI panel shows continuous communication error with PLC

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the bus address configured in WinCC flexible matches the physical DIP switch or software address setting on the panel and PLC.

    Replace or reseat the communication cable. Ensure termination resistors are active only at the two physical ends of the bus. Correct any address conflicts on the network and power cycle both the panel and PLC.

    Project transfer from PC to panel fails

    Confirm the panel is in transfer mode by accessing the loader menu on startup. Check the PC adapter cable type and the selected communication port in WinCC flexible transfer settings.

    Set the panel to transfer mode via the loader. Select the correct COM port or USB adapter in the WinCC flexible transfer dialog. Ensure the baud rate matches between the PC adapter and the panel configuration.

    Operator keys are unresponsive or intermittently responsive

    Inspect the membrane keypad surface for physical damage, contamination, or deformation. Test each key systematically using the panel's built-in key test function available in the loader menu.

    Clean the keypad surface with a dry cloth. If individual keys are confirmed faulty through the key test, the membrane keypad assembly requires replacement. This is a hardware repair requiring panel disassembly.

    Panel repeatedly restarts or enters an error loop after project download

    Check the WinCC flexible project for configuration errors such as invalid tag addresses, unsupported functions for the OP 77B hardware, or firmware version mismatches.

    Reopen the project in WinCC flexible and run the project consistency check. Correct any reported errors. Ensure the firmware version on the panel matches the requirements of the project and update if necessary before re-downloading.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart