• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7ER0 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7ER0 OP 77B

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6355-1CA47-7ER0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7ER0 is an operator panel belonging to the OP 77B series within Siemens' SIMATIC HMI product line. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a keypad-based interface for process monitoring and control. As part of the SIMATIC HMI Basic Panels family, it is engineered for integration with Siemens S7 PLC systems and is configured using SIMATIC WinCC flexible software.

    The OP 77B features a monochrome LCD display and a membrane keypad with function keys, system keys, and numeric entry keys for operator input. It supports MPI and PROFIBUS DP communication interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 controllers. The unit operates on a 24 V DC supply and is built to withstand industrial environments, carrying a front panel protection rating of IP65. Configuration and project transfer is handled via an RS-232 serial interface or MPI connection.

    The OP 77B is widely deployed in manufacturing, process automation, and machine tool applications where a cost-effective, robust operator interface is required without the need for a full graphical touchscreen. It is particularly suited for applications such as packaging machinery, conveyor systems, and general-purpose machine control where alphanumeric display and keypad interaction are sufficient. Its compact form factor and panel-mount design make it suitable for integration into standard control cabinets and machine enclosures.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 lines x 20 characters
    Input Voltage 24 V DC
    Voltage Tolerance 19.2 V DC to 28.8 V DC
    Power Consumption Max. 4 W
    Communication Interface MPI, PROFIBUS DP, RS-232
    Configuration Software SIMATIC WinCC flexible 2005 or higher
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series SIMATIC HMI OP 77B

    Common Error Codes and System Events

    Event ID: 10000
    Configuration error detected during startup; project data on the device is invalid or corrupted.
    Re-transfer a valid project from WinCC flexible to the device via MPI or RS-232 connection.
    Event ID: 20000
    Communication connection to the PLC has been lost or cannot be established.
    Check MPI or PROFIBUS DP cabling and termination resistors. Verify PLC address settings match the HMI project configuration.
    Event ID: 40000
    Operating system or firmware error detected on the panel.
    Perform a firmware update using the ProSave tool or WinCC flexible. If the issue persists, perform a factory reset.
    Event ID: 50000
    Internal device memory error or memory overflow condition.
    Reduce the project size or number of tags. Transfer a new, optimized project to the device.
    Event ID: 60000
    Tag or variable update timeout; the PLC is not responding to data requests within the configured cycle time.
    Increase the acquisition cycle time in the project configuration or check PLC program scan time and communication load.
    Event ID: 70000
    Illegal system state detected; the panel has entered an undefined operating mode.
    Cycle power to the panel. If the fault recurs, reload the project and update the firmware to the latest version.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7ER0)?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via the PPI protocol using the RS-232 port with an appropriate adapter.

    What software is used to configure and program the OP 77B?

    The OP 77B is configured using Siemens SIMATIC WinCC flexible 2005 or later versions. Projects are transferred to the device via MPI connection or RS-232 serial interface.

    What is the supply voltage for the 6AV6355-1CA47-7ER0?

    The device requires a 24 V DC supply voltage with an acceptable range of 19.2 V DC to 28.8 V DC.

    What is the front panel protection rating of the OP 77B?

    The front panel of the OP 77B carries an IP65 protection rating, making it suitable for environments where dust and water spray may be present.

    Can the OP 77B display graphical content?

    No, the OP 77B uses a character-based monochrome LCD display and does not support graphical or bitmap image display. It is designed for alphanumeric text and status indication only.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check that the voltage is within the 19.2 V to 28.8 V range. Inspect the supply cable and connector for damage.

    Correct the supply voltage if out of range. Replace the power supply cable or connector if damaged. If voltage is correct and display remains blank, the internal power supply or LCD backlight may have failed and the unit requires repair or replacement.

    HMI cannot establish communication with the PLC

    Verify the MPI or PROFIBUS DP bus address configured in the HMI project matches the physical settings on the PLC. Check the bus cable for continuity and correct termination at both ends of the network segment.

    Correct any address mismatches in the WinCC flexible project and re-transfer to the panel. Replace damaged bus cables and ensure termination resistors are enabled only at the two physical ends of the bus.

    Project transfer from WinCC flexible fails or times out

    Check the RS-232 or MPI cable connection between the PC and the OP 77B. Confirm the correct COM port and transfer settings are selected in WinCC flexible. Verify the panel is in transfer mode.

    Place the panel in transfer mode by navigating to the transfer menu on the device. Use a known-good MPI or RS-232 cable. Reinstall the WinCC flexible communication driver on the PC if the connection is still not recognized.

    Function keys do not respond to presses

    Inspect the membrane keypad for physical damage, contamination, or deformation. Test each key systematically using the panel's built-in key test function if available in the service menu.

    Clean the keypad surface with a dry cloth. If individual keys are unresponsive due to membrane damage, the keypad membrane assembly must be replaced. Contact a qualified repair technician for membrane replacement.

    Panel repeatedly restarts or enters a fault loop on startup

    Attempt to access the panel's start menu during boot by holding the appropriate key combination. Check whether a valid project is loaded on the device. Inspect the supply voltage for instability or ripple.

    Re-transfer a valid project using WinCC flexible. If the panel cannot boot to the transfer menu, perform a firmware recovery using the Siemens ProSave tool via RS-232. Ensure the power supply is stable and free of excessive ripple.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart