Siemens 6AV6355-1CA47-7EJ0 OP 77B
€ 162,97
The Siemens 6AV6355-1CA47-7EJ0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. It is a compact, key-operated operator panel designed for straightforward machine-level human-machine interface tasks. This unit provides a text-based display interface and is part of Siemens' established line of operator panels for industrial automation environments.
The OP 77B features a 4-line text display capable of showing alphanumeric characters, enabling clear status and process value visualization. It communicates via MPI and PROFIBUS DP interfaces, allowing direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and supports alarm management, recipe handling, and trend display functions within its operational scope.
The OP 77B is widely deployed in manufacturing, process automation, and machine building applications where a cost-effective, robust operator interface is required. Its compact form factor and membrane keypad make it suitable for installation in control cabinet doors and machine panels where space is limited. Industries such as packaging, automotive assembly, and general factory automation commonly utilize this panel for local operator control and monitoring tasks.
Technical Specifications
| Display Type | STN LCD, text-based |
|---|---|
| Display Lines | 4 lines |
| Characters per Line | 20 characters |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 4.5 W (typical) |
| Communication Interface | MPI, PROFIBUS DP |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Configuration Software | WinCC flexible 2008 or later |
| Series/Product Family | SIMATIC HMI OP 77B |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the operator panel and the connected PLC. The panel cannot establish or maintain a connection to the configured controller.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Connection to the PLC was interrupted during operation. The panel lost communication with the configured controller.
Inspect the communication cable for damage or loose connectors. Verify network termination and cable shielding. Restart both the panel and the PLC and monitor for recurrence. - Event ID: 20000
- Configuration or project download error. The panel could not accept or load the project transferred from the engineering station.
Verify the WinCC flexible project is compatible with the OP 77B firmware version. Re-transfer the project using the correct communication settings and ensure sufficient panel memory is available. - Event ID: 40000
- System memory error. The panel has detected an issue with its internal memory or stored project data.
Perform a panel reset and re-download the project. If the error persists, the internal memory may be corrupted and the unit may require repair or replacement. - Event ID: 50000
- Firmware or operating system error detected during panel startup or operation.
Attempt a firmware update using the appropriate Siemens update tool. If the panel fails to boot, a factory reset or hardware service may be required. - Event ID: 60000
- Power supply voltage out of range. The panel has detected that the supply voltage is outside the permissible 24 V DC operating range.
Measure the supply voltage at the panel power connector. Ensure the supply is stable and within the 20.4 V DC to 28.8 V DC tolerance range. Check for loose wiring or an undersized power supply.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7EJ0)?
The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication. It can also communicate with S7-200 via the PPI protocol.
What software is used to configure and program the OP 77B?
The OP 77B is configured using Siemens WinCC flexible 2008 or a compatible later version. Projects are transferred to the panel via the MPI interface or a direct PC adapter connection.
What is the supply voltage requirement for this operator panel?
The OP 77B requires a 24 V DC supply voltage, with a permissible range of approximately 20.4 V DC to 28.8 V DC. An external regulated DC power supply must be used.
What is the front panel protection rating of the OP 77B?
The front panel of the OP 77B carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.
Can the OP 77B display graphics or only text?
The OP 77B is a text-based operator panel and does not support graphical displays. It shows alphanumeric characters across 4 lines of 20 characters each.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power supply terminals of the panel. Inspect the supply cable and connector for damage or incorrect wiring.
Ensure the power supply is within the 20.4 V DC to 28.8 V DC range. If voltage is correct and the display remains blank, the internal power supply or display unit may be faulty and require repair.
Panel shows communication error and cannot connect to PLC
Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the PLC address and baud rate configured in WinCC flexible match the actual PLC settings.
Correct any address or baud rate mismatches in the WinCC flexible project and re-download. Replace the communication cable if damaged. Ensure bus termination resistors are active only at the physical ends of the network.
Project download fails from engineering PC to panel
Confirm the PC adapter or MPI cable is correctly connected and the correct COM port and transfer speed are selected in WinCC flexible. Check that the panel is in transfer mode.
Set the panel to transfer mode via the Start Center menu. Verify the WinCC flexible project version is compatible with the panel firmware. Retry the transfer at a lower baud rate if errors persist.
Operator keys are unresponsive or register incorrect inputs
Inspect the membrane keypad for physical damage, contamination, or deformation. Test individual keys in the panel's system menu if accessible.
Clean the keypad surface with a dry cloth. If specific keys are permanently unresponsive, the membrane keypad assembly may need replacement. Contact a qualified repair technician for keypad replacement.
Panel repeatedly restarts or fails to complete boot sequence
Check the supply voltage stability under load. Inspect for any error messages displayed briefly during the boot cycle, which may indicate a firmware or memory fault.
Stabilize the power supply and ensure it is adequately rated for the panel load. Attempt a firmware update or factory reset. If the issue persists, internal hardware failure is likely and the unit should be sent for repair.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page