Siemens 6AV6355-1CA47-7EA2 OP 77B
€ 994,88
The Siemens 6AV6355-1CA47-7EA2 is an operator panel belonging to the OP 77B series within the SIMATIC HMI product family. This compact panel is designed for machine-level human-machine interface applications, providing operators with a straightforward interface for monitoring and controlling industrial processes. It is a key component in Siemens' range of Basic Panels, offering reliable performance in demanding industrial environments.
The OP 77B features a monochrome STN display with a resolution of 160 x 80 pixels and a membrane keypad for operator input, eliminating the need for a touchscreen. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and offers a compact, robust housing rated to IP65 on the front face, suitable for panel mounting in industrial cabinets.
The OP 77B is widely used in manufacturing, machine building, and process automation applications where a cost-effective, reliable operator interface is required. It is particularly suited for smaller machines and standalone equipment where basic process visualization, alarm display, and parameter entry are needed. Industries such as packaging, food and beverage, and general factory automation commonly deploy this panel for local operator control stations.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Display Size | 4 inch |
| Input Method | Membrane keypad |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 4.8 W |
| Communication Interface | MPI, PROFIBUS DP |
| Configuration Software | WinCC flexible 2005 or higher |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI OP 77B |
Common Error Codes and System Events
- Event ID: 10000
- Configuration error detected during startup; the loaded project is incompatible or corrupted.
Re-download the project from WinCC flexible to the panel. Verify the project version matches the panel firmware version. - Event ID: 20000
- Communication connection to the PLC has been lost or cannot be established.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the panel configuration. - Event ID: 40000
- Internal device error or hardware fault detected.
Perform a factory reset and re-download the project. If the fault persists, the panel may require repair or replacement. - Event ID: 50000
- Operator panel memory is full; no further data logging or alarm archiving is possible.
Clear the alarm buffer and data logs via the panel's system settings. Reduce the number of archived entries in the project configuration. - Event ID: 60000
- Firmware update failed or firmware version mismatch detected.
Repeat the firmware update procedure using the correct firmware version for this panel. Ensure stable power supply during the update process. - Event ID: 70000
- Tag update error; one or more process tags cannot be read from the connected controller.
Verify PLC tag addresses in the WinCC flexible project. Check that the PLC program is running and the relevant data blocks or memory areas are accessible. - Event ID: 30000
- Panel operating system error or watchdog timeout occurred.
Cycle power to the panel. If the error recurs, perform a factory reset and reload the project firmware and configuration.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B panel?
The OP 77B is compatible with Siemens S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via the PPI protocol.
What software is used to configure the 6AV6355-1CA47-7EA2?
The panel is configured using Siemens WinCC flexible 2005 or a later version. Projects are downloaded to the panel via MPI, PROFIBUS DP, or a USB/serial connection.
What is the supply voltage for this operator panel?
The OP 77B requires a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to avoid damage or malfunction.
Does the OP 77B support touchscreen input?
No, the OP 77B uses a membrane keypad for operator input and does not feature a touchscreen. Navigation and data entry are performed using the dedicated function and system keys.
What is the front panel protection rating of the 6AV6355-1CA47-7EA2?
The front face of the panel is rated to IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial panel door mounting.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector. Verify the supply is within the specified tolerance and measure current draw to detect a possible internal short.
Ensure the 24 V DC supply is stable and correctly wired. If the supply is confirmed good and the display remains blank, the internal power supply or display unit may be faulty and the panel should be sent for repair.
Panel displays 'No connection to PLC' or communication errors at startup
Inspect the MPI or PROFIBUS DP cable for damage, correct pin assignment, and proper bus termination at both ends. Verify that the PLC address configured in the WinCC flexible project matches the actual PLC station address.
Replace or reseat the communication cable. Correct the bus termination by enabling termination resistors only at the physical ends of the bus. Update the PLC address in the project and re-download if necessary.
Panel freezes or becomes unresponsive during operation
Determine whether the freeze is triggered by a specific operator action or occurs randomly. Check for memory overflow in the alarm buffer or data logs via the panel system menu.
Clear the alarm buffer and reduce the number of logged entries. Perform a power cycle. If the issue persists, perform a factory reset and re-download the firmware and project configuration.
Membrane keypad keys are unresponsive or intermittently register inputs
Inspect the keypad surface for physical damage, contamination, or deformation. Test each key systematically using the panel's built-in key test function available in the service menu.
Clean the keypad surface with a dry cloth. If individual keys are mechanically damaged or the keypad overlay is worn, the front panel membrane assembly should be replaced.
Project download fails or WinCC flexible cannot connect to the panel
Check the communication cable between the programming PC and the panel. Verify the correct COM port and transfer settings are selected in WinCC flexible. Confirm the panel is in transfer mode.
Switch the panel to transfer mode manually via the Start Center menu. Use a known-good PC adapter cable (e.g., PC/MPI adapter). If the connection still fails, perform a factory reset to restore the panel to its default transfer-ready state.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page