• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7EA1 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7EA1 OP 77B

    € 1.287,43

    Reset
    Clear
    SKU: 6AV6355-1CA47-7EA1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7EA1 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. This compact panel provides a text-based operator interface for machine-level control and monitoring tasks. It is designed for use with Siemens SIMATIC S7 PLCs and other compatible controllers, offering a reliable and cost-effective HMI solution for straightforward automation applications.

    The OP 77B features a 4-line text display with a resolution of 4 x 20 characters, capable of displaying alphanumeric information clearly in industrial environments. It supports MPI and PROFIBUS DP communication interfaces for direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel includes a membrane keypad with function keys, system keys, and numeric entry keys, and is configured using the WinCC flexible Micro or STEP 7 Micro/WIN software. It operates on a 24 V DC supply and carries an IP65 protection rating on the front face, making it suitable for panel-mount installations in demanding environments.

    The OP 77B is widely deployed in machine building, conveyor systems, packaging machinery, and general factory automation where simple text-based status display and parameter entry are required. Its compact form factor and straightforward configuration make it appropriate for OEM machine builders seeking a low-cost operator interface. The panel is particularly common in retrofit and upgrade projects replacing older OP7 and OP17 units in existing SIMATIC installations.

    Technical Specifications

    Display Type Text LCD
    Display Lines x Characters 4 x 20 characters
    Communication Interface MPI, PROFIBUS DP
    Input Voltage 24 V DC
    Voltage Tolerance 19.2 V DC – 28.8 V DC
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 %, non-condensing
    Mounting Panel mount
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible Micro, STEP 7 Micro/WIN
    Compatible Controllers SIMATIC S7-200, S7-300, S7-400

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the OP 77B and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    PLC connection timeout. The panel has lost communication with the configured PLC after an initial connection was established.
    Inspect the communication cable for damage or loose connectors. Check for address conflicts on the MPI or PROFIBUS network. Restart both the panel and the PLC.
    Event ID: 20000
    Configuration download error. A fault occurred during the transfer of the project configuration from the engineering PC to the OP 77B.
    Verify the serial or MPI transfer cable is correctly connected. Ensure the panel is in transfer mode before initiating the download. Check that the WinCC flexible Micro project is compatible with the OP 77B firmware version.
    Event ID: 40000
    Operating system error or internal panel fault detected during startup or operation.
    Perform a panel reset by cycling power. If the fault persists, reload the operating system firmware using the appropriate Siemens ProSave tool.
    Event ID: 50000
    Firmware version mismatch between the panel operating system and the loaded project configuration.
    Update the panel firmware to the version required by the project using ProSave, or recompile and reload the project using the matching version of WinCC flexible Micro.
    Event ID: 60000
    Panel memory error. Insufficient memory available to load or run the configured project.
    Reduce the size of the project by limiting the number of screens, tags, or alarm messages. Ensure no unnecessary data is included in the project configuration.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7EA1)?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with certain third-party controllers that support these protocols.

    What software is used to configure the OP 77B?

    The OP 77B is configured using WinCC flexible Micro for S7-300 and S7-400 applications, or STEP 7 Micro/WIN for S7-200 applications. Both tools allow creation of text screens, tags, and alarm messages.

    What is the supply voltage for the 6AV6355-1CA47-7EA1?

    The panel requires a 24 V DC supply with an acceptable range of 19.2 V DC to 28.8 V DC. An external 24 V DC power supply must be provided as the panel does not include an integrated power supply.

    Can the OP 77B replace an older OP7 or OP17 panel?

    Yes, the OP 77B is designed as a functional replacement for the older OP7 and OP17 operator panels. Existing projects may require adaptation in WinCC flexible Micro before downloading to the new panel.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout with the supplied gasket.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel power connector. Verify the voltage is within the 19.2 V to 28.8 V range. Check the supply cable and connector for damage or poor contact.

    Correct the supply voltage if out of range. Replace the supply cable or connector if damaged. If the supply is confirmed good and the display remains blank, the internal power supply or display unit may have failed and the panel should be sent for repair or replacement.

    Panel displays 'No connection to PLC' or communication error message

    Check the MPI or PROFIBUS DP cable between the panel and the PLC. Verify bus termination is correctly applied at both ends of the network. Confirm the PLC address and baud rate in the panel project match the actual PLC settings.

    Replace or reseat the communication cable. Correct any address or baud rate mismatches in the WinCC flexible Micro project and reload the configuration. Ensure only one termination resistor is active at each end of the bus.

    Project download from PC to panel fails or times out

    Confirm the panel is set to transfer mode before initiating the download. Check the serial or MPI programming cable connection between the PC and the panel. Verify the WinCC flexible Micro software version is compatible with the panel firmware.

    Restart the panel in transfer mode and retry the download. Replace the programming cable if it is suspected to be faulty. Update the panel firmware using ProSave if a version mismatch is identified.

    Function keys do not respond or produce incorrect actions

    Check the project configuration in WinCC flexible Micro to verify the correct functions are assigned to each key. Inspect the membrane keypad for physical damage or contamination under the keys.

    Reload the correct project configuration to the panel. If the keypad is physically damaged or keys are unresponsive despite correct configuration, the membrane keypad assembly requires replacement.

    Panel repeatedly restarts or shows operating system fault on startup

    Attempt a controlled power cycle. If the fault persists on every startup, the panel firmware may be corrupted or the internal flash memory may have failed.

    Use the Siemens ProSave tool to reload the panel operating system firmware via the serial interface. If firmware reload does not resolve the issue, the panel hardware requires professional repair or replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart