• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7DM0 OP 177B
    Awaiting product image

    Siemens 6AV6355-1CA47-7DM0 OP 177B

    € 554,45

    Reset
    Clear
    SKU: 6AV6355-1CA47-7DM0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7DM0 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with keypad-based operation, enabling operators to monitor and control industrial processes directly at the machine. It is part of Siemens' established SIMATIC HMI portfolio, which is widely deployed across discrete and process manufacturing environments.

    The OP 177B features a 5.7-inch STN display and supports both MPI and PROFIBUS DP communication interfaces, allowing seamless integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel includes configurable function keys, a numeric/alphanumeric keypad, and supports WinCC flexible as its configuration software. It offers a compact, panel-mount design with an IP65 protection rating on the front face, making it suitable for installation in control cabinet doors exposed to dust and splash water.

    The OP 177B is commonly used in machine building, automotive assembly lines, packaging machinery, and material handling systems where a robust, keypad-operated HMI is preferred over a touchscreen. Its compatibility with the SIMATIC S7 PLC family and support for PROFIBUS DP makes it a practical choice for integration into existing Siemens automation architectures. The panel is well-suited for applications requiring reliable operator input and process visualization in industrial environments.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Colors 256 colors
    Display Resolution 320 x 240 pixels (QVGA)
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI, PROFIBUS DP, RS-422/485
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front), IP20 (rear)
    Mounting Panel mounting
    Configuration Software WinCC flexible 2005 or higher
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the configured controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during operation.
    Inspect communication cables for damage or loose connectors. Check bus termination and cable shielding. Restart the HMI panel and verify PLC status.
    Event ID: 20000
    Project download error. The configuration project could not be transferred to the panel.
    Verify the PC-to-panel communication cable is correctly connected. Check that the WinCC flexible project is compiled without errors and that the correct panel type is selected.
    Event ID: 40000
    System memory low. Available memory on the HMI device is insufficient to load or run the project.
    Reduce the size of the HMI project by removing unused screens, images, or variables. Ensure no unnecessary background applications are running on the panel.
    Event ID: 50000
    Internal device error. A hardware or firmware fault has been detected within the panel.
    Perform a panel restart. If the error persists, update the panel firmware using ProSave. If the fault continues, the unit may require hardware repair or replacement.
    Event ID: 60000
    Configuration error. The loaded project contains settings incompatible with the current panel firmware version.
    Update the panel firmware to the version required by the WinCC flexible project. Alternatively, recompile the project targeting the installed firmware version and re-download.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 177B (6AV6355-1CA47-7DM0)?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports connections to S7-1200 and third-party controllers via RS-422/485 in certain configurations.

    What software is used to configure the OP 177B?

    The OP 177B is configured using Siemens WinCC flexible 2005 or a later version. Projects are downloaded to the panel via a PC adapter cable connected to the MPI or PROFIBUS DP port.

    What is the front panel protection rating of the OP 177B?

    The front face of the OP 177B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets. The rear of the unit is rated IP20.

    Can the OP 177B be used as a replacement for the OP 170B?

    The OP 177B is the successor to the OP 170B and is generally compatible in terms of form factor and communication interfaces. However, the project configuration must be migrated and re-downloaded using WinCC flexible.

    What is the supply voltage for the OP 177B?

    The OP 177B operates on a 24 V DC supply voltage. Ensure the power supply can deliver sufficient current, as the panel consumes up to 9 W during normal operation.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply terminals. Measure voltage at the panel connector to confirm supply integrity. Inspect the internal fuse if accessible.

    Ensure the power supply is correctly wired and delivering 24 V DC. Replace any blown fuse with the correct rating. If the display backlight has failed, the panel may require backlight or display module replacement.

    HMI panel shows 'No connection to PLC' message during operation

    Verify the MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check bus termination resistors are enabled only at the physical ends of the bus segment. Confirm the PLC node address matches the address configured in the WinCC flexible project.

    Re-seat all communication connectors. Enable bus termination only at the two physical ends of the network. Correct any address mismatches in the HMI project and re-download the configuration.

    Project download fails from WinCC flexible to the panel

    Confirm the PC adapter (USB or MPI) is correctly installed and the COM port or USB driver is recognized by Windows. Check that the panel is in transfer mode and not running a project that blocks the download.

    Place the panel in transfer mode via the Start Center menu. Reinstall the PC adapter driver if necessary. Ensure the WinCC flexible project targets the correct panel type and firmware version before initiating the transfer.

    Touchscreen or keypad inputs are not responding correctly

    For keypad issues, check for physical damage to the membrane keys. Verify the project configuration assigns the correct function to each key. For unresponsive keys, test each key individually in the panel's diagnostic mode.

    Recalibrate the keypad assignments in the WinCC flexible project if functions are incorrectly mapped. If physical keys are damaged or stuck, the keypad membrane may need replacement. Clean the keypad surface to remove any contamination causing key sticking.

    Panel repeatedly restarts or enters a boot loop

    This may indicate a corrupted project file on the panel or a firmware issue. Attempt to access the Start Center during boot by pressing the appropriate key combination. Check if the panel boots successfully without a project loaded.

    Delete the existing project from the panel using the Start Center and re-download a freshly compiled project from WinCC flexible. If the boot loop persists without a project, update the panel firmware using Siemens ProSave software via the MPI interface.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart