• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7DL1 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7DL1 OP 77B

    € 1.025,73

    Reset
    Clear
    SKU: 6AV6355-1CA47-7DL1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7DL1 is an operator panel belonging to the OP 77B series within Siemens' SIMATIC HMI product line. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a straightforward interface for process visualization and control. As part of the SIMATIC HMI Basic Panels family, it is engineered to integrate seamlessly with Siemens SIMATIC S7 programmable logic controllers.

    The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels, offering clear readability in industrial environments. It supports MPI and PROFIBUS DP communication interfaces, enabling direct connection to S7-200, S7-300, and S7-400 PLCs without additional hardware. The panel includes function keys and a numeric keypad for operator input, and is configured using Siemens WinCC flexible engineering software. It operates on a 24 V DC supply and carries an IP65 protection rating on the front face, making it suitable for panel-mount installations in demanding environments.

    The OP 77B is widely used in manufacturing, machine building, and process automation applications where a cost-effective, reliable operator interface is required. It is particularly suited for controlling and monitoring individual machines or small automation cells in industries such as automotive, food and beverage, packaging, and general manufacturing. Its compact form factor and robust construction make it appropriate for integration into control cabinets and machine panels with limited space.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Resolution 160 x 80 pixels
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mount
    Certifications CE, UL
    Engineering Software WinCC flexible
    Series/Product Family SIMATIC HMI OP 77B

    Common Error Codes and System Events

    Event ID: 1000
    System startup completed successfully. The panel has booted and is ready for operation.
    No action required. This is an informational event confirming normal startup.
    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection has been interrupted or cannot be established.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and running. Confirm communication parameters (station address, baud rate) match on both devices.
    Event ID: 10001
    Timeout on the communication link to the PLC. The panel did not receive a response within the expected time.
    Verify network cable integrity and connector seating. Check for address conflicts on the MPI or PROFIBUS network. Reduce network load if multiple nodes are present.
    Event ID: 20000
    Tag read error. The panel was unable to read the value of a configured tag from the PLC.
    Confirm the tag address exists and is accessible in the PLC program. Check that the data block or memory area referenced is not write-protected or out of range.
    Event ID: 20001
    Tag write error. The panel was unable to write a value to the configured PLC tag.
    Verify the target PLC address is writable and within valid range. Check PLC operating mode — the PLC must be in RUN mode to accept write operations from the HMI.
    Event ID: 40000
    Project download error. A project transfer to the panel was interrupted or failed.
    Check the transfer cable connection and PC communication settings. Ensure WinCC flexible is configured with the correct transfer interface and panel type. Retry the download.
    Event ID: 50000
    Internal device error. A hardware or firmware fault has been detected within the panel.
    Perform a power cycle. If the error persists, perform a factory reset via the panel's loader menu. If unresolved, the unit may require repair or replacement.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B?

    The OP 77B supports direct connection to Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via PPI protocol.

    What software is used to configure the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible engineering software. Projects are created on a PC and transferred to the panel via a PC/MPI adapter or PROFIBUS connection.

    What is the supply voltage for the 6AV6355-1CA47-7DL1?

    The panel operates on a 24 V DC supply voltage, which is the standard supply used across the SIMATIC HMI Basic Panel range.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.

    Can the OP 77B display alarm messages?

    Yes, the OP 77B supports alarm and event logging functionality, allowing operators to view active alarms and alarm history directly on the panel display using configured alarm screens.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel's power connector using a multimeter. Verify polarity is correct and voltage is within the specified range.

    Restore correct 24 V DC supply. If supply is confirmed correct and display remains blank, the internal power supply or backlight may have failed, requiring unit repair or replacement.

    Panel cannot establish communication with the PLC

    Verify MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Check that station addresses and baud rate settings match on both devices. Use a bus diagnostic tool to check network integrity.

    Correct any mismatched communication parameters in the WinCC flexible project and PLC configuration. Replace damaged cables or connectors. Ensure bus termination resistors are correctly placed at both ends of the network.

    Project transfer from PC to panel fails

    Confirm the transfer cable (PC/MPI adapter or USB-MPI adapter) is correctly connected and recognized by the PC. Check that the panel is in transfer mode via the loader menu.

    Set the panel to transfer mode by accessing the loader on startup. Verify the correct communication port and transfer speed are selected in WinCC flexible. Replace the transfer cable if it is faulty.

    Operator inputs via function keys are not responding

    Check whether the panel is in runtime mode and the project is correctly loaded. Test individual keys by navigating the loader menu to confirm hardware key functionality.

    Reload the project from WinCC flexible if key assignments are missing or corrupted. If keys are physically unresponsive in the loader menu as well, the keypad membrane may be worn or damaged and the unit should be sent for repair.

    Alarm messages are not appearing on the display

    Verify that alarm tags are correctly configured in the WinCC flexible project and that the corresponding PLC bit addresses are being set by the PLC program during fault conditions.

    Correct tag address assignments in the WinCC flexible project and retransfer the project to the panel. Confirm the PLC program logic is correctly setting the alarm trigger bits.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart