Siemens 6AV6355-1CA47-7DC3 OP 77B
€ 419,36
The Siemens 6AV6355-1CA47-7DC3 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a keypad-based interface for process monitoring and control. It is part of the SIMATIC HMI Basic Panels generation and is manufactured by Siemens AG as a robust, industrial-grade operator device.
The OP 77B features a monochrome LCD display with a resolution of 160 x 64 pixels and a membrane keypad for operator input, eliminating the need for a touchscreen. It supports MPI and PROFIBUS DP communication interfaces for direct integration with Siemens S7-200, S7-300, and S7-400 PLCs, as well as connections via the PPI protocol. The panel is configured using WinCC flexible software and offers a compact memory footprint suitable for straightforward HMI tasks including alarm display, recipe management, and parameter setting.
The OP 77B is widely deployed in manufacturing machinery, packaging equipment, conveyor systems, and process automation installations where a cost-effective, reliable operator interface is required without the complexity of a full graphical touchscreen panel. Its compact form factor and keypad-based operation make it particularly suitable for environments where simplified operator interaction and robust mechanical durability are priorities. The panel is commonly found in automotive supply, food and beverage, and general factory automation applications.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Resolution | 160 x 64 pixels |
| Display Size | 4 lines of text |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 4 W (typical) |
| Communication Interface | MPI, PROFIBUS DP, PPI |
| Configuration Software | WinCC flexible 2008 or later |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC HMI OP 77B |
Common Error Codes and System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI/PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Connection timeout to the configured PLC. The panel did not receive a response from the controller within the expected time window.
Check network cabling and connector integrity. Verify baud rate settings on both the HMI and PLC match. Restart both devices and re-establish communication. - Event ID: 20000
- Project download error. The configuration project could not be successfully transferred to the panel.
Verify the USB or MPI connection between the engineering PC and the panel. Ensure the WinCC flexible project is compiled without errors before downloading. Check available memory on the panel. - Event ID: 40000
- Tag read/write error. The HMI panel is unable to read from or write to a configured PLC tag.
Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program for address conflicts or protected data areas. - Event ID: 50000
- System memory low. The panel's available runtime memory is insufficient for the current project.
Reduce the number of active alarms, screens, or recipe entries in the project. Recompile and re-download the project. Consider simplifying the HMI application. - Event ID: 70000
- Alarm buffer overflow. The number of pending or logged alarms has exceeded the panel's alarm buffer capacity.
Acknowledge and clear existing alarms on the panel. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm triggers. Archive alarm logs if required. - Event ID: 80000
- Operating system error or firmware fault detected on the panel.
Perform a panel reset by cycling power. If the fault persists, re-flash the panel firmware using the Siemens ProSave tool via the MPI or USB interface.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B panel?
The OP 77B supports communication with Siemens S7-200 (via PPI), S7-300, and S7-400 PLCs (via MPI or PROFIBUS DP). It also supports connection to SIMATIC S7-1200 with appropriate configuration in WinCC flexible.
What software is required to configure the 6AV6355-1CA47-7DC3?
The panel is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are compiled and downloaded to the panel via MPI connection or USB programming cable.
What is the supply voltage for this operator panel?
The OP 77B requires a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid panel faults.
Does the OP 77B support recipe management?
Yes, the OP 77B supports basic recipe management functionality, allowing operators to store and recall parameter sets directly from the panel keypad.
What is the IP protection rating of the OP 77B front panel?
The front face of the OP 77B is rated IP65, making it suitable for installation in environments where dust and water spray protection is required.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the panel power connector. Verify polarity is correct and the supply is within tolerance. Inspect the internal fuse if accessible.
Ensure the 24 V DC supply is stable and correctly wired. If the supply is confirmed good and the display remains blank, the panel may require internal repair or replacement of the power supply board.
Panel displays 'No connection to PLC' or communication error on startup
Verify the MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check that bus termination resistors are correctly placed at both ends of the network segment.
Correct any wiring faults and ensure termination is applied. Confirm that the PLC station address and baud rate in the HMI project match the physical PLC configuration. Restart both devices after making changes.
Panel keypad buttons are unresponsive or intermittently responsive
Inspect the membrane keypad for physical damage, contamination, or deformation. Check the internal ribbon cable connection between the keypad membrane and the main PCB.
Clean the keypad surface with a dry cloth. If the ribbon cable is loose or damaged, reseat or replace it. If the keypad membrane itself is faulty, replace the membrane assembly.
Project download fails or is interrupted during transfer
Check the MPI cable or USB programming cable for damage. Verify the engineering PC recognises the panel and the correct COM port or MPI adapter is selected in WinCC flexible.
Replace the programming cable if damaged. Ensure the panel is in transfer mode before initiating the download. Recompile the WinCC flexible project and retry the download with the panel freshly powered.
Alarm messages are displayed in incorrect language or with garbled text
Check the language settings within the WinCC flexible project. Verify that the correct language pack has been downloaded to the panel and that the active language index is correctly configured.
Re-download the project with the correct language configuration. Ensure the font used in the project is compatible with the OP 77B display resolution and character set.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page