Siemens 6AV6355-1CA47-7CL0 OP 77B
€ 386,38
The Siemens 6AV6355-1CA47-7CL0 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing a text-based display for process visualization and operator control. It is a successor to earlier OP7 and OP17 panels and is engineered for integration into standard industrial control environments.
The OP 77B features a 4-line text display capable of showing alphanumeric characters, along with a membrane keypad for operator input including function keys, numeric keys, and system keys. It supports the MPI and PROFIBUS-DP communication interfaces, enabling direct connection to Siemens S7-200, S7-300, and S7-400 PLCs without an additional communications module. The unit operates on 24 V DC supply voltage and is rated IP65 at the front panel, providing protection against dust and water jets in industrial environments.
The OP 77B is typically deployed in machine building, manufacturing automation, and process control applications where a cost-effective, compact operator interface is required. It is well suited for conveyor systems, packaging machinery, and general-purpose machine control panels where text-based status display and parameter entry are sufficient. Its slim form factor and standard panel cutout dimensions make it straightforward to integrate into existing control cabinet doors and machine panels.
Technical Specifications
| Display Type | 4-line text display (STN) |
|---|---|
| Display Characters per Line | 20 characters |
| Input/Operating Voltage | 24 V DC |
| Permissible Voltage Range | 19.2 V DC to 28.8 V DC |
| Power Consumption | Max. 5 W |
| Communication Interface | MPI, PROFIBUS-DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Compatible PLCs | SIMATIC S7-200, S7-300, S7-400 |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the OP 77B and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration in WinCC flexible. - Event ID: 10001
- Connection to the PLC has been interrupted during runtime.
Inspect the communication cable for damage or loose connectors. Verify PLC is powered and running. Check network topology and bus termination. - Event ID: 20000
- Configuration error detected. The project loaded on the panel is incompatible or corrupt.
Re-download the project from WinCC flexible to the panel. Ensure the correct panel type is selected in the project settings. - Event ID: 40000
- System memory low or memory overflow condition detected on the panel.
Reduce the number of active alarms or data records. Check project size and optimize the WinCC flexible project to reduce memory usage. - Event ID: 50000
- Internal device error or hardware fault detected.
Perform a panel reset. If the fault persists, check the 24 V DC supply voltage and replace the unit if no external cause is found. - Event ID: 60000
- Tag update error. A process tag could not be read from or written to the PLC.
Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program for address conflicts.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B (6AV6355-1CA47-7CL0)?
The OP 77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS-DP interfaces. It can also communicate with S7-200 via PPI protocol.
What software is used to configure and program the OP 77B?
The OP 77B is configured using Siemens WinCC flexible software. The project is then downloaded to the panel via the MPI interface or a PC adapter cable.
What is the supply voltage for the 6AV6355-1CA47-7CL0?
The unit requires a 24 V DC supply voltage with a permissible range of 19.2 V DC to 28.8 V DC.
What is the front panel protection rating of the OP 77B?
The front panel of the OP 77B is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial machine panel mounting.
Can the OP 77B display graphics or only text?
The OP 77B is a text-based operator panel and displays alphanumeric characters only. It does not support graphical visualization; for graphical displays, a panel such as the TP 177 or MP series should be considered.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the voltage is within the 19.2 V to 28.8 V range.
Correct any supply voltage issues. If voltage is correct and the display remains blank, the internal power supply or display unit may be faulty and the panel should be repaired or replaced.
Panel shows communication error or cannot connect to PLC
Verify MPI or PROFIBUS-DP cable connections at both the panel and PLC ends. Check that bus termination resistors are correctly placed at both ends of the network segment.
Replace or reseat the communication cable. Confirm that the PLC station address and baud rate in the WinCC flexible project match the PLC configuration. Ensure the PLC is in RUN mode.
Keypad buttons are unresponsive or intermittently responsive
Inspect the membrane keypad for physical damage, contamination, or wear. Test each key systematically in the panel's diagnostic or test mode if available.
Clean the keypad surface with a dry cloth. If keys remain unresponsive, the membrane keypad assembly requires replacement, which is a common wear component on this panel type.
Project download from WinCC flexible fails
Check the PC-to-panel connection cable (MPI/PC adapter). Verify the correct COM port and transfer speed are selected in WinCC flexible transfer settings.
Switch the panel to transfer mode manually via the panel start screen. Reinstall the PC adapter driver if necessary and retry the download. Ensure the WinCC flexible version supports the OP 77B panel type.
Alarm messages are not displayed or are missing on the panel
Check the alarm configuration in the WinCC flexible project, including the PLC bit addresses assigned to each alarm. Verify the PLC program is setting the correct alarm bits.
Correct any mismatched tag addresses in the alarm configuration. Re-download the updated project to the panel and confirm the PLC program logic is activating the expected alarm bits.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page