• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7CF1 OP 177B
    Awaiting product image

    Siemens 6AV6355-1CA47-7CF1 OP 177B

    € 1.221,47

    Reset
    Clear
    SKU: 6AV6355-1CA47-7CF1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7CF1 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color display with touch and key-based operation, serving as a compact yet capable panel for process visualization and control. It is part of Siemens' established SIMATIC HMI portfolio, engineered for integration into industrial control cabinets and machinery.

    The OP 177B features a 5.7-inch STN display and supports both MPI/PROFIBUS DP and Ethernet (PROFINET) communication interfaces, enabling flexible integration with SIMATIC S7 PLCs and other compatible controllers. The panel is configured using WinCC flexible engineering software and supports recipe management, alarm logging, and trend display functions. It operates on 24 V DC supply and is built to withstand the demands of industrial environments, with a front panel protection rating of IP65.

    The OP 177B is widely deployed in manufacturing, machine building, and process automation applications where a compact operator interface is required at the machine level. It is suitable for use with conveyor systems, packaging machinery, press lines, and general-purpose automation equipment. Its combination of key-based and touch operation makes it adaptable to environments where gloved operation or precise input is required.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Colors 256 colors
    Touch Technology Touch screen and membrane keys
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 12 W
    Communication Interface MPI/PROFIBUS DP, Ethernet (PROFINET), RS-422/485
    Configuration Software WinCC flexible 2005 or higher
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
    Check MPI/PROFIBUS DP or Ethernet cable connections and termination resistors. Verify PLC address settings and communication parameters in WinCC flexible project match the hardware configuration.
    Event ID: 10001
    Connection to PLC timed out. The panel did not receive a response from the controller within the expected time window.
    Verify the PLC is powered and running. Check network cabling and bus termination. Confirm the station address configured in the HMI project matches the PLC hardware address.
    Event ID: 20000
    Tag read error. The HMI panel was unable to read a configured tag from the PLC.
    Verify the tag address exists in the PLC program and that the data block or memory area is accessible. Check for address mismatches between the HMI project and the PLC program.
    Event ID: 20001
    Tag write error. The HMI panel was unable to write a value to a configured PLC tag.
    Confirm the PLC is in RUN mode and the target memory area is not write-protected. Check tag addressing in the WinCC flexible project for correctness.
    Event ID: 40000
    Project download error. A fault occurred during transfer of the HMI project from the engineering PC to the panel.
    Ensure the correct transfer cable or network connection is used. Verify WinCC flexible version compatibility with the panel firmware. Restart the panel in transfer mode and retry the download.
    Event ID: 50000
    Internal device error or system fault detected on the HMI panel.
    Perform a power cycle on the panel. If the fault persists, reset the panel to factory defaults via the Start Center menu. If unresolved, the panel may require repair or replacement.
    Event ID: 60000
    Insufficient memory on the HMI panel. The project or runtime data exceeds available storage capacity.
    Reduce the size of the HMI project by removing unused screens, tags, or archived data. Transfer a revised project to the panel.
    Event ID: 70000
    Firmware version mismatch. The firmware on the panel is incompatible with the downloaded project version.
    Update the panel firmware to the version required by the WinCC flexible project, or recompile the project using a WinCC flexible version compatible with the installed firmware.

    Frequently Asked Questions

    What communication interfaces does the OP 177B (6AV6355-1CA47-7CF1) support?

    The OP 177B supports MPI, PROFIBUS DP, and Ethernet (PROFINET) interfaces, as well as RS-422/485 serial communication, allowing connection to a wide range of SIMATIC S7 PLCs and third-party controllers.

    Which engineering software is required to configure this panel?

    The OP 177B is configured using Siemens WinCC flexible 2005 or a later version. Projects created in WinCC flexible can be transferred to the panel via MPI, PROFIBUS, Ethernet, or USB connection.

    Is the OP 177B compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the OP 177B is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with S7-200 PLCs via the RS-422/485 interface using the appropriate protocol settings.

    What is the front panel protection rating of this unit?

    The front panel of the OP 177B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for installation in industrial cabinet doors.

    Can the OP 177B be operated with gloves?

    Yes, the OP 177B includes physical membrane function keys in addition to the touch screen, allowing operation with gloves in environments where direct touch screen input may not be practical.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel power connector. Check that polarity is correct and voltage is within the specified range. Inspect the power supply cable and connector for damage.

    Correct any wiring or polarity issues. If supply voltage is confirmed correct and the display remains blank, the internal power supply or backlight may have failed and the unit should be sent for repair.

    Panel displays 'No connection to PLC' or communication alarm on startup

    Check the communication cable between the HMI and PLC for continuity and correct pin assignment. Verify bus termination resistors are correctly placed at both ends of the PROFIBUS or MPI segment.

    Replace or reseat the communication cable. Correct bus termination. Confirm that the PLC station address in the HMI project matches the physical PLC configuration. Restart both devices after corrections.

    Touchscreen does not respond or responds inaccurately to input

    Check whether the touch screen responds at all or only in certain areas. Attempt a touch screen calibration from the Start Center or Control Panel menu on the panel.

    Recalibrate the touch screen via the panel's Start Center settings. If calibration does not resolve the issue, the touch screen overlay may be damaged and the unit requires hardware repair.

    Project download fails or transfer is interrupted

    Verify the panel is in transfer mode (accessible via Start Center). Check the transfer cable or Ethernet connection between the engineering PC and the panel. Confirm the WinCC flexible project version is compatible with the panel firmware version.

    Switch the panel to transfer mode manually. Use a known-good transfer cable or network connection. Update panel firmware if a version mismatch is identified, then retry the project download.

    Panel repeatedly restarts or enters a boot loop

    A corrupted project or firmware image can cause repeated restarts. Attempt to access the Start Center during boot by pressing the appropriate key combination. Check if the panel reaches the Start Center or fails before that point.

    If the Start Center is accessible, delete the current project and reload a known-good project. If the panel cannot reach the Start Center, a firmware recovery procedure using a memory card or PC Tool may be required.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart